SEARCH · Search NASA
Results for “wood building”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Characterization of wood fiber insulation for the development of wood fiber-insulated panels (WIPs) for use in building envelope
Wood fiber insulation (WFI) was studied as an eco-friendly alternative for fossil-based building insulation, focusing on its use in new wood fiber-insulated panels (WIPs). Rigid WFI boards with densities of 110, 140, and 180 kg/m³, including a 140 kg/m³ variant without paraffin wax, were evaluated. Key properties investigated included porosity, water vapor transmission, liquid water adsorption, and thermal conductivity. The porosity ranged between 85 and 92%, primarily influenced by density. Water vapor permeability ranged from 65 to 90 ng·s-1m-1Pa-1, while liquid water absorption was between 2.5 and 20% by volume, influenced by both wax and density. The thermal conductivity coefficient ranged from 0.038 to 0.055 W/(m·K). Bond strength tests with WFI (140 kg/m³ with wax) laminated to various materials using structural adhesives showed tensile perpendicular-to-grain strengths of 10 to 16 kPa and shear strengths of 60 to 90 kPa, with failure only occurring within the WFI. It was concluded that WFI is a promising material for novel WIPs, offering competitive hygrothermal properties and compatibility with structural adhesives. However, its bio-based nature suggests variability and complexity, necessitating further rigorous testing in various climates and in more complex assemblies.
Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort
Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.
Sustainable Wood-Waste-Based Thermal Insulation Foam for Building Energy Efficiency
Wood is one of the most abundant biomaterials on Earth, which has been used for centuries in construction applications including furniture, roofing, flooring, and cabinetry. However, wood chips—which are a low-quality and plentiful waste byproduct of lumber milling, woodworking, and shipping operations—have low economic value and complicated disposal methods. In this paper, we propose a strategy for wood chip reuse through the fabrication of bio-based building insulation foam. Through a high-temperature chemical treatment delignification process, we introduced additional small pores within the wood chips, effectively lowering their thermal conductivity, and used them in combination with a binding agent to produce a porous insulation foam. The porous insulation foam achieved a low thermal conductivity of 0.038 W/(m·K) and a high compressive strength of 1.1 MPa (70% strain). These characteristics demonstrate that wood waste can be repurposed into an effective building material, addressing challenges in both waste management and sustainable construction.
Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort
Explore the source record for details and available documents.
Cross-Laminated Timber Workshop: Pathways and Priorities for Cross-Laminated Timber Building Systems
A virtual workshop titled "BTO Cross-Laminated Timber Workshop: Pathways and Priorities for CLT Building Systems," was held on April 19, 2021, to identify research and development pathways, including the embodied energy content, operational energy efficiency, wall moisture profiles, structural connector durability, and health monitoring systems for CLT wall systems. In the workshop, perspectives were gathered from a wide range of stakeholders across North America from academia, the mass timber industry, trade groups, and federal government departments. The participants had knowledge in one or more areas of CLT building performance, production and construction, supply and demand dynamics of CLT panels, building codes, and recycling of CLT panels. To capture potential research opportunities from the participants in the mass timber field, the workshop was structured with the following objectives: 1. Identify the research and development opportunities to overcome technology gaps, integration issues, and market adoption challenges that are currently preventing the greater deployment of CLT, and 2. Understand what priorities and pathways are needed to advance energy efficient, high- rise CLT building systems.
CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing
Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.
Comparative life cycle assessment of a modular cross-laminated timber residential building designed for disassembly and reuse versus traditional wood frame construction
There is a need for affordable housing across the U.S., with high-performance modular and prefabricated buildings providing a logical avenue for meeting some of this demand. However, there is a need to balance high performance construction – including low emissions – with affordability. To provide a proof-of-concept in meeting these goals, the Circular Home is a cross-laminated timber (CLT)-based deconstructible and reconfigurable single-family residence that meets high performance targets in moisture, energy, design, economics, and life cycle assessment (LCA). This study focuses on the LCA, presenting a cradle-to-cradle whole-building life cycle assessment (WBLCA) for the Circular Home and a functionally equivalent Baseline Home constructed with traditional materials and methods. The functional unit is 1 m 2 of gross floor area across 60 years. Revit building information models (BIM) provided material quantities and Tally LCA was utilized for impact data (inclusive of biogenic carbon sequestration), supplemented with manufacturer environmental product declarations (EPDs). The Circular Home outperforms the baseline residence in most measured impact categories, including global warming potential (GWP), producing −2.73 kgCO 2 eq/m 2 in embodied emissions, whereas the modeled baseline has an embodied GWP of 428 kgCO 2 eq/m 2 . The careful material selection and advanced building design optimizes performance, with the Circular Home containing only −0.006 times the embodied emissions and −0.02 times the operational emissions of its traditional counterpart. Finally, the unique contribution of this work is in the environmental impact comparison of a high-performance modular CLT structure that can be affordably scaled and mass produced in a U.S. market, compared to typical single family home construction.
Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance
The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.
Global warming potential estimates of mass timber constructions beyond the first life: A dynamic radiative forcing modeling approach
In the face of a warming planet, steps must be taken to reduce the greenhouse gas emissions (GHG) associated with our building industry, which is a significant contributor to global emissions. Large, prefabricated wood elements such as mass timber panels (MTP) have great potential to achieve these reductions as they help displace high-embodied‑carbon materials like concrete and steel. Furthermore, storing the wood's biogenic carbon in buildings benefits the climate because it delays the eventual release of the carbon into the atmosphere. While these climate impacts have been assessed for the construction phase of mass timber buildings, relatively few life cycle assessment (LCA) studies have evaluated the climate impacts for the buildings' end-of-life (EOL) phase. This research estimates the climate impacts of four EOL scenarios for MTP: reusing as MTP, recycling into particleboard, incinerating, and landfilling. Using dynamic radiative forcing modeling and factoring in temporal GHG emissions and biogenic carbon storage, the global warming potential impacts are calculated for construction, deconstruction, and EOL processing of hybrid mass timber buildings in the U.S. Pacific Northwest for 160 years (GWP 160 ). The 160-year temporal scale used in this paper is an arbitrary scale, with the first 80 years being the assumed life of the building, followed by a series of reuse, recycle, or disposal scenarios over the second 80 years of that temporal scale. Of the four EOL scenarios considered in this paper, the ‘reuse’ scenario has the lowest net GWP 160 impact (calculated by summing the GWP 160 and carbon storage benefits, i.e., GWP$^{bioCS}_{160}$ ), emerging as a climate-preferred scenario, followed by ‘landfill’, ‘incinerate’, and ‘recycle’ scenarios. The lower net GWP 160 impact associated with the reuse scenario is due to the low fossil carbon emissions during EOL processing, as well as the biogenic carbon storage benefits. The results of this study also highlight the importance of efficient reuse and recycling strategies for wood in MTP.
Comparison of Mechanical Properties of Lignin/High-Density Polyethylene (HDPE) Composites and Wood/HDPE Composites
Lignin is a plant-derived, the second most abundant natural polymer, and a waste byproduct of the pulp industry. Incorporation of lignin into plastic composites using scalable approaches is commercially favored and low carbon-cost. Potential end applications for lignin plastic composites (LPCs) could be found in buildings and furniture where wood plastic composites (WPCs) are used in various components. This study compares the mechanical properties of LPCs and WPCs, aiming at the examination of the viability of the use of LPCs as alternative materials to WPCs in the building industry. Sodium ligninsulfonate (SLS)-based LPC blended with high-density polyethylene (HDPE) (45 wt.%) and maleic anhydride grafted polyethylene (MAPE) as a compatibilizer (5 wt.%) reached flexural strength (35.17 and 30.92 MPa respectively) and moduli (2.87 and 1.79 GPa respectively) comparable to benchmarking WPCs. Lignin dealkaline (LD)-based LPC exhibited higher ultimate strain but lower strength than SLS-based LPC, probably due to fragmentation during the post-sulfite treatment steps.
Three-dimensional printing of wood
Natural wood has served as a foundational material for buildings, furniture, and architectural structures for millennia, typically shaped through subtractive manufacturing techniques. However, this process often generates substantial wood waste, leading to material inefficiency and increased production costs. A potential opportunity arises if complex wood structures can be created through additive processes. Here, we demonstrate an additive-free, water-based ink made of lignin and cellulose, the primary building blocks of natural wood, that can be used to three-dimensional (3D) print architecturally designed wood structures via direct ink writing. The resulting printed structures, after heat treatment, closely resemble the visual, textural, olfactory, and macro-anisotropic properties, including mechanical properties, of natural wood. Our results pave the way for 3D-printed wooden construction with a sustainable pathway to upcycle/recycle natural wood.
Performance of a Hybrid HVAC-Integrated Thermal Storage Device
Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.
Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings
Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.
Chemical composition of material extractives influences microbial growth and dynamics on wetted wood materials
The impact of material chemical composition on microbial growth on building materials remains relatively poorly understood. We investigate the influence of the chemical composition of material extractives on microbial growth and community dynamics on 30 different wood species that were naturally inoculated, wetted, and held at high humidity for several weeks. Microbial growth was assessed by visual assessment and molecular sequencing. Unwetted material powders and microbial swab samples were analyzed using reverse phase liquid chromatography with tandem mass spectrometry. Different wood species demonstrated varying susceptibility to microbial growth after 3 weeks and visible coverage and fungal qPCR concentrations were correlated (R 2 = 0.55). Aspergillaceae was most abundant across all samples; Meruliaceae was more prevalent on 8 materials with the highest visible microbial growth. A larger and more diverse set of compounds was detected from the wood shavings compared to the microbial swabs, indicating a complex and heterogeneous chemical composition within wood types. Several individual compounds putatively identified in wood samples showed statistically significant, near-monotonic associations with microbial growth, including C 11 H 16 O 4 , C 18 H 34 O 4 , and C 6 H 15 NO. A pilot experiment confirmed the inhibitory effects of dosing a sample of wood materials with varying concentrations of liquid C 6 H 15 NO (assuming it presented as Diethylethanolamine).
Big Box Retail Grocery Store and Electric Vehicle Station Load Profiles
This dataset includes yearlong, one-minute resolution time series profiles for the big box retail grocery stores stores simulated in Phoenix, Houston, Denver, and Minneapolis, as well as electric vehicle charging time series profiles for the various ports, charging levels, and station utilizations produced for the study "Impact of electric vehicle charging on the power demand of retail buildings", published in 2021 (https://doi.org/10.1016/j.adapen.2021.100062). Please cite as: Gilleran, M., Bonnema, E., Woods, J. et al. Impact of electric vehicle charging on the power demand of retail buildings. Advances in Applied Energy 4, (2021). https://doi.org/10.1016/j.adapen.2021.100062
The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization
To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.