Search NASA⌕ Search

SEARCH · Search NASA

Results for “working fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heat dissipation systems with hygroscopic working fluid

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid and methods of using the same. In various embodiments, the present invention provides a method for heat dissipation using a hygroscopic working fluid. The method can include transferring thermal energy from a heated process fluid to the hygroscopic working fluid in a process heat exchanger, to form a cooled process fluid. The method can include condensing liquid from a feed gas on a heat transfer surface of a feed gas heat exchanger in contact with the cooled process fluid, to form a cooled feed gas, the heated process fluid, and a condensate. The method can include dissipating thermal energy from the hygroscopic working fluid to a cooling gas composition with a fluid-air contactor. The method can include transferring moisture between the hygroscopic working fluid and the cooling gas composition with the fluid-air contactor. The method can include adding at least part of the condensate to the hygroscopic working fluid.

Martin, Christopher Lee↗

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

Martin, Christopher L.↗

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

42 ENGINEERING↗

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

Martin, Christopher L.↗

Effect of Mixed Working Fluid Composition on Binary Cycle Condenser Heat Transfer Coefficients

Effect of Mixed Working Fluid Composition on Binary Cycle Condenser Heat Transfer Coefficients Dan Wendt, Greg Mines Idaho National Laboratory The use of mixed working fluids in binary power plants can provide significant increases in plant performance, provided the heat exchangers are designed to take advantage of these fluids non-isothermal phase changes. In the 1980's testing was conducted at DOE's Heat Cycle Research Facility (HCRF) where mixtures of different compositions were vaporized at supercritical pressures and then condensed. This testing had focused on using the data collected to verify that Heat Transfer Research Incorporated (HTRI) codes were suitable for the design of heat exchangers that could be used with mixtures. The HCRF data includes mixture compositions varying from 0% to 40% isopentane and condenser tube orientations of 15{sup o}, 60{sup o}, and 90{sup o} from horizontal. Testing was performed over a range of working fluid and cooling fluid conditions. Though the condenser used in this testing was water cooled, the working fluid condensation occurred on the tube-side of the heat exchanger. This tube-side condensation is analogous to that in an air-cooled condenser. Tube-side condensing heat transfer coefficient information gleaned from the HCRF testing is used in this study to assess the suitability of air-cooled condenser designs for use with mixtures. Results of an air-cooled binary plant process model performed with Aspen Plus indicate that that the optimal mixture composition (producing the maximum net power for the scenario considered) is within the range of compositions for which data exist. The HCRF data is used to assess the impact of composition, tube orientation, and process parameters on the condensing heat transfer coefficients. The sensitivity of the condensing coefficients to these factors is evaluated and the suitability of air-cooled condenser designs with mixtures is assessed. This paper summarizes the evaluation of the HCRF data and discusses the next steps in the project evaluation of air-cooled condenser designs that can take advantage of the performance gains possible with these fluids.

15 GEOTHERMAL ENERGY↗

A Comprehensive Review of Working Fluids for High-Temperature Heat Pumps: History, Selection, and Evaluation

High-temperature heat pumps (HTHPs) are essential for enhancing energy efficiency across various industrial applications, especially in terms of integrating with renewable energy sources and recovering waste heat. This article thoroughly investigates suitable working fluids for HTHPs, highlighting the evolution from traditional refrigerants to contemporary alternatives with low global warming potential (GWP). It proposes comprehensive selection criteria for these working fluids, pre-selects low-GWP working fluids, and outlines a screening methodology. The pre-selected low-GWP working fluids are evaluated for applications in three typical industrial scenarios involving HTHPs. Furthermore, this study demonstrates that regulatory compliance and environmental impacts significantly influence the development of next-generation refrigerants. The choice of working fluids is closely linked to the types of vapor compression cycles, tailored to the specific industrial applications for HTHPs. This study emphasizes areas for future research, including the development of innovative working fluids; integrated strategies that account for performance, safety, and regulatory standards; alignment of HTHP components; exploration of natural working fluids; and broadening the applications of existing working fluids.

Compression↗

Working fluid selection for organic Rankine cycle power generation using hot produced supercritical CO 2 from a geothermal reservoir

Geothermal heat mining simulations using supercritical CO 2 (sCO 2 ) were performed in this research. Working fluid selection criteria for power generation using sCO 2 from a geothermal reservoir are then presented for subcritical, superheated and supercritical organic Rankine cycles (ORCs). Meanwhile, method of working fluid classification for ORC is proposed. To get the most feasible ORC design, this study introduces the concept of “turning point” for isentropic and dry working fluids, as well as minimum turbine inlet temperature for wet working fluids. A thermodynamic model was developed with capabilities to obtain the optimal working fluid mass flow rate, evaporation temperature, superheated temperature, and supercritical pressure, to evaluate the thermal performance of the three ORC approaches using hot produced sCO 2 . With this model, thirty potential working fluids with critical temperatures in the range from 50 to 225 °C were screened for utilizing hot produced sCO 2 considering physical properties, environmental and safety impacts, and thermodynamic performances. Finally, the thermodynamic results were compared for all possible working fluids.

15 GEOTHERMAL ENERGY↗

Testing of Crystallization Temperature of a New Working Fluid for Absorption Heat Pump Systems

Lithium bromide/water (LiBr/water) absorption systems are potential candidates for absorption heat pump water heating applications since they have been widely commercialized for cooling applications. One drawback to LiBr/water absorption water heater systems is that they are unable to operate at typical water heating temperatures due to solution crystallization hazards. Binary or ternary mixtures, serving as working fluids, were reported (Ally, 1988; Herold et al., 1991; Iyoki and Uemura, 1981; Yasuhide Nemoto et al., 2010; Zogg et al., 2005) to help improve the absorption performance or avoid crystallization of absorption heat pump systems. A recent development (De Lucas et al., 2007) investigated the use of a ternary mixture of aqueous mixture of lithium bromide and sodium formate (CHO2Na). The new working fluid composition maintains a ratio of LiBr/CHO2Na of 2 by weight. This new working fluid is a potential competitor to aqueous LiBr solution in absorption system due to higher water vapor absorption rates and lower generation temperature needed (De Lucas et al., 2004). There exists data on equilibrium performance and other physical properties of this new working fluid. However, there is no available data on crystallization behavior. Crystallization temperature is crucial for the design of absorption heat pump water heater in order to avoid crystallization hazards during operation. We have therefore conducted a systematic study to explore the crystallization temperature of LiBr/CHO2Na water solution and compared it against aqueous LiBr solutions. These results were then used to evaluate the feasibility of using the new working fluid in water heating applications showing limited potential.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Working Fluid Characterization and Performance Assessment of Subcritical Organic Rankine Cycles Based on the Lee–Kesler Approach for Energy Recovery

Here, a generalized model using the Lee–Kesler approach based on the corresponding states principle is developed to assess the performance of subcritical Organic Rankine Cycles operating with different working fluids. Each fluid is characterized by five parameters: the acentric factor, critical temperature, critical pressure, molar mass, and the ideal-gas ratio of specific heats at the critical temperature. The model was developed using the compressibility factor modified version of the Benedict–Webb–Rubin equation proposed by Lee and Kesler and the enthalpy and entropy functions to calculate thermodynamic state properties. The model was validated by comparing the results calculated with the model and working fluid thermodynamic properties obtained with the CoolProp database. This comparison was conducted for 91 working fluids, obtaining a relative error below 5% for 88 out of the 91 fluids (∼97%). A generalized parametric study was conducted to determine the influence of the pinch point and each fluid parameter on the performance of Organic Rankine Cycle (ORC) systems. It was found that efficiency increases with critical temperature, ideal-gas ratio of specific heats at the critical temperature, and acentric factor, reaching up to 13%. The developed model enables the evaluation of ORC system performance for existing working fluids. It also allows the formulation and evaluation of new fluids to enhance the performance of the ORC while retrieving energy from any kind of source; and likewise, the methodology can be applied to other power generation cycles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mixtures of SF6 CO2 as working fluids for geothermal power plants

In this paper, supercritical/transcritical thermodynamic cycles using mixtures of SF6 CO2 as working fluids were investigated for geothermal power plants. The system of equations that described the thermodynamic cycle was solved using a Newton-Raphson method. This approach allows a high computational efficiency even when thermophysical properties of the working fluid depend strongly on the temperature and pressure. The thermophysical properties of the mixtures were obtained from National Institute of Standards and Technology (NIST) REFPROP software and constituent cubic equations. The local heat transfer coefficients in the heat exchangers were calculated based on the local properties of the working fluid, geothermal brine, and cooling water. The heat exchanger areas required were calculated. Numerical simulation results presented for different cycle configurations were used to assess the effects of the SF6 fraction in CO2, brine temperature, and recuperator size on the cycle thermal efficiency, and size of heat exchangers for the evaporator and condenser. Optimal thermodynamic cycle efficiencies were calculated to be approximately 13 and 15% mole content of SF6 in a CO2- SF6 mixture for a Brayton cycle and a Rankine cycle, respectively.

Yin, Hebi↗

Influence of Steam Delivery of the Working Fluid on Tool Wear

The delivery of working fluid to the cutting zone in a current of steam supplied by a steam generator is considered. This method improves the machining of metals, reduces tool wear, and improves the surface quality of the product.

42 ENGINEERING↗

An experimental study on the performance of closed loop pulsating heat pipe (CLPHP) with methanol as a working fluid

Thermal control is an important topic for thermal management of small electrical and electronic devices. Closed loop pulsating heat pipe (CLPHP) arises as the best solution for thermal control. The aim of this experimental study is to search a CLPHP of better thermal performance for cooling different electrical and electronic devices. In this experiment, methanol is used as working fluid. The effect of using methanol as a working fluid is studied on thermal performance in different filling ratios and angles of inclination. A copper capillary tube is used where the inner diameter is 2 mm,outer diameter is 2.5 mm and 250 mm long. The CLPHP has 8 loops where the evaporation section is 50 mm, adiabatic section is 120 mm and condensation section is 80 mm. The experiment is done using FR of 40%-70% with 10% of interval and angles of inclination 0° (vertical), 30°, 45°, 60° varying heat input. The results are compared on the basis of evaporator temperature, condenser temperature and their differences, thermal resistance, heat transfer co-efficient, power input and pulsating time. The results demonstrate the effect of methanol in different filling ratios and angles of inclination. M ethanol shows better performance at 30° inclination with 40% FR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THERMO-HYDRO-MECHANICAL MODELING OF WORKING FLUID INJECTION AND THERMAL ENERGY EXTRACTION IN EGS FRACTURES AND ROCK MATRIX

Development of enhanced geothermal systems (EGS) will require creation of a reservoir of sufficient volume to enable commercial-scale heat transfer from the reservoir rocks to the working fluid. A key assumption associated with reservoir creation/stimulation is that sufficient rock volumes can be hydraulically fractured via both tensile and shear failure, and more importantly by reactivation of naturally existing fractures (by shearing), to create the reservoir. The advancement of EGS greatly depends on our understanding of the dynamics of the intimately coupled rock-fracture-fluid-heat system and our ability to reliably predict how reservoirs behave under stimulation and production. Reliable performance predictions of EGS reservoirs require accurate and robust modeling for strongly coupled thermal-hydrological-mechanical (THM) processes. Conventionally, these types of problems have been solved using operator-splitting methods, usually by coupling a subsurface flow and heat transport simulators with a solid mechanics simulator via input files. An alternative approach is to solve the system of nonlinear partial differential equations that govern multiphase fluid flow, heat transport, and rock mechanics simultaneously, using a fully coupled, fully implicit solution procedure, in which all solution variables (pressure, enthalpy, and rock displacement fields) are solved simultaneously. This paper describes numerical simulations used to investigate the poro- and thermal- elastic effects of working fluid injection and thermal energy extraction on the properties of the fractures and rock matrix of a hypothetical EGS reservoir, using a novel simulation software FALCON (Podgorney et al., 2011), a finite element based simulator solving fully coupled multiphase fluid flow, heat transport, rock deformation, and fracturing using a global implicit approach. Investigations are also conducted on how these poro- and thermal-elastic effects are related to fracture permeability evolution.

15 GEOTHERMAL ENERGY↗

System and Component Transport Considerations of Micro-Pin Based Solar Receivers With High Temperature Gaseous Working Fluids

This paper explores the interactions between micro-pin concentrated receiver designs with overall solar thermal energy system performance, with different operating conditions, working fluid, and required materials of construction. A 320 MW thermal plant coupled to a 160 MW electric sCO2 Brayton cycle is considered as the baseline. The circulating fluid enters the receiver at 550°C, and leaves at 720°C. The thermal storage/power block are located 150 m from the receiver at the base of the receiver tower. A resistance network based thermal and hydraulic model is used to predict heat transfer and pressure drop performance of the micro-pin receiver. This output of this model is coupled to a system level model of the pressure loss and compressor power required in the remainder of the high temperature gas loop. Overall performance is investigated for supercritical carbon dioxide and helium as working fluids, at pressures from 7.5 to 25 MPa, and at delivery temperatures of 720°C. The results show that by modifying pin depth and flow lengths, there are design spaces for micro-pin devices that can provide high thermal performance without significantly reducing the overall solar thermal system output at lower operating pressures. Use of lower pressure fluids enables lower cost materials of construction in the piping and distribution system, reducing the cost of electricity.

14 SOLAR ENERGY↗

Thermal Stability of Cyclopentane as an Organic Rankine Cycle Working Fluid

Laboratory experiments were performed to aid in determining the maximum operating temperature for cyclopentane as an Organic Rankine Cycle working fluid. The thermochemical decomposition of cyclopentane was measured in a recirculation loop at 240 C, 300 C and 350 C at 43 bar in a glass-lined heated tube. It was determined that in the absence of air at the lower two temperatures, decomposition was minor after more than twelve days of continuous operation. At 240 C, the total cyclopentane decomposition products were approximately 65 parts per million (ppm) and at 300 C, total decomposition products were on the order of 270 ppm at the end of the experiment. At 350 C, decomposition products were significantly higher and reached 1,500 ppm. When the feed was contacted with air, the decomposition rate increased dramatically. Residues found in the reactor after the decomposition experiments were examined by a number of different techniques. The mass of the residues increased with experimental temperature, but was lower at the same temperature when the feed was contacted with air. Analysis of the residues suggested that the residues were primarily heavy saturated hydrocarbons.

42 ENGINEERING↗

CO 2 -based mixtures as working fluids for geothermal turbines

Sandia National Laboratories (Sandia) is investigating advanced Brayton cycles using supercritical working fluids for application to a variety of heat sources, including geothermal, solar, fossil, and nuclear power. This work, under the Sandia and U.S. Department of Energy (DOE) Office of Advanced Reactor Concepts, is centered on the supercritical CO 2 (S-CO 2 ) power conversion cycle, which has the potential for high efficiency in the temperature range of interest for these heat sources and is very compact—a feature likely to reduce capital costs. As the S-CO 2 program progresses to a full Brayton power-generating cycle, new strategies are being pursued with a focus towards further pushing cycle efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MIXTURES OF CO2-SF6 AS WORKING FLUIDS FOR GEOTHERMAL PLANTS

In this paper, mixtures of CO2 and SF6 were evaluated as working fluids for geothermal plants based on property measurements, molecular dynamics modeling, thermodynamic cycle analysis, and materials compatibility assessment. The CO2 - SF6 was evaluated for a reservoir temperature of 160 oC. Increasing the efficiency for these low reservoir sources will increase the options available for geothermal energy utilization in more sites across the country. The properties for the mixtures were obtained either from thermodynamic property measurements and molecular dynamics simulations. Optimum compositions of the CO2 - SF6 were identified for a well reservoir temperature and a given water-cooling condition. Concerning the global warming potential, it was estimated that the equivalent CO2 emissions per 1kWh for a Rankine cycle operating with 100% SF6 would be approximately of 7.6% than those for a coal-fired power plant.

15 GEOTHERMAL ENERGY↗

Tailored Working Fluids for Enhanced Binary Geothermal Power Plants

United Technologies Research Center (UTRC), in collaboration with the Georgia Institute of Technology and the National Institute of Standards and Technology will evaluate and develop fundamental and component level models, conduct experiments and generate data to support the use of mixed or enhanced working fluids for geothermal power generation applications.

15 GEOTHERMAL ENERGY↗