Replication of x-ray blazed gratings by nano-inscribing.

A nano-inscribing technique was tested as a method of cost-effective replication of blazed diffraction gratings for x-rays. A saw-tooth mold for the nano-inscribing was fabricated by a double-replication process from a master blazed grating. The nano-inscribing was performed using a UV-curable resist of low viscosity to provide a small thickness of the resist replicas, required for a following transfer process. The nano-inscribing process was optimized to minimize surface relaxation and preserve the saw-tooth shape of the grooves, required for high diffraction efficiency. The quality of the replica gratings was evaluated via diffraction efficiency simulations. The simulations demonstrated that near theoretical efficiency can be achieved for the x-ray gratings made by the nano-inscribing approach.

blazed grating↗

Nanometer flat blazed x-ray gratings using ion beam figure correction

With the development of nanometer accuracy stitching interferometry, ion beam figuring (IBF) of x-ray mirrors can now be achieved with unprecedented performance. However, the process of producing x-ray diffraction gratings on these surfaces may degrade the figure quality due to process errors introduced during the ruling of the grating grooves. To address this challenge, we have investigated the post-production correction of gratings using IBF, where stitching interferometry is used to provide in-process feedback. A concern with ion beam correction in this case is that ions will induce enough surface mobility of atoms to cause smoothing of the grating structure and degradation of diffraction efficiency. In this study we found however that it is possible to achieve a nanometer-level planarity of the global grating surface with IBF, while preserving the grating structure. The preservation was so good, that we could not detect a change in the diffraction efficiency after ion beam correction. This is of major importance in achieving ultra-high spectral resolution, and the preservation of brightness for coherent x-ray beams.

36 MATERIALS SCIENCE↗

Advanced low blaze angle x-ray gratings via nanoimprint replication and plasma etch

We developed a new method of making ultra-low blaze angle diffraction gratings for x-ray applications. The method is based on reduction of the blaze angle of a master grating by nanoimprint replication followed by a plasma etch. A master blazed grating with a relatively large blaze angle is fabricated by anisotropic wet etching of a Si single crystal substrate. The surface of the master grating is replicated by a polymer material on top of a quartz substrate by nanoimprinting. Then a second nanoimprinting is performed using the 1st replica as a mold to replicate the saw-tooth surface into a resist layer on top of a Si grating substrate. A reactive ion etch is used to transfer the grating grooves into the Si substrate. The plasma etch provides reduction of the groove depth by a factor defined by the ratio of the etch rates for the resist and Si. We demonstrate reduction of the blaze angle of a master grating by a factor of 5 during fabrication of a 200 lines/mm blazed grating with a blaze angle of 0.2°. We investigated the quality and performance of the fabricated low blaze angle gratings and evaluate process accuracy and reproducibility. The new blaze angle reduction method preserves the planarity of the optical surface of the grating substrate and at the same time provides improvement in the grating groove quality during the reduction process.

47 OTHER INSTRUMENTATION↗

Fabrication and characterization of a full-size ultra-precise lamellar grating for the Cosmic beamline at ALS-U

We have developed a new process for the production of ultra-precise variable line spacing (VLS) lamellar diffraction gratings through nanofabrication. The process enables the fabrication of full-size X-ray gratings with sub-nanometre accuracy in groove depth, an optimal land-to-groove ratio, and uniform groove depth across the entire grating area. We also established a method for evaluating VLS groove density variation using stitched Fizeau interferometry. The measurements confirmed the exceptionally high accuracy of the VLS groove density in the fabricated gratings, which is well within the specification tolerances while the residual groove density errors are vanishingly small. The gold-coated grating demonstrated near-theoretical diffraction efficiency across the energy range of 100–1200 eV.

36 MATERIALS SCIENCE↗

A high transmission tender X-ray monochromator employing a matched pair of multilayer grating and mirror

It is now well established that multilayer coated gratings may offer high diffraction efficiencies over the tender X-ray range, from about 1 keV to 5 keV, covering the gap between single layer coated grating monochromators and crystal monochromators. Nevertheless, few beamlines in the world are using such gratings in their monochromator. The successful implementation of a multilayer grating monochromator requires producing a matched pair of a multilayer grating and a multilayer mirror, and this matching is not straightforward as it must account for different incidence angles and refraction effects on each element. Here we review the realization of the multilayer grating monochromator of the SIRIUS beamline which has been successfully in service for several years. We show how, by alternating computer simulation with our diffraction code and measurements, we could optimize the monochromator transmission on a very wide energy range. After the grating was coated, it was found that the angle of optimal efficiency versus photon energy was significantly different from what was predicted by a simple conformal model of binary layers. Layer interdiffusion and profile smoothing during the deposition process must be added to the multilayer model to reproduce the measured data. The critical adjustment of the mirror multilayer period is achieved by the lateral translation of the mirror, which was given a small transverse period gradient. The monochromator is thus providing high transmission efficiency in the 1 to 5 keV energy range, more than 30% over 2.5 keV and up to 46% at 4.6 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Harmonic suppression gratings for soft X-ray monochromators

We describe an approach to harmonic suppression in soft X-ray monochromators by engineering the reflection grating’s diffraction pattern to approximate a sinusoidal amplitude. At synchrotron and free-electron laser sources, X-ray beamlines powered by insertion devices produce a spectrum containing harmonic photon energies that can couple unwanted light into experiments. Beamlines in the soft X-ray energy range (100 eV to 2 keV) commonly employ energy-filtering elements to suppress these harmonics. Available approaches tend to be inefficient, significantly reducing the transmitted power. We show that with pseudo-grayscale binary halftone patterns, gratings can approximate a sinusoidal amplitude and suppress higher diffraction orders. Prototype demonstrations of lithographically fabricated gratings were conducted on a soft X-ray beamline with photon energies of 110 eV and 330 eV. Relative to a square-wave amplitude grating, the third-harmonic intensity was reduced by a factor of 9.0 with a first-order efficiency reduction of 38%.

Goldberg, Kenneth A. [Lawrence Berkeley National L↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Hard x-ray – optical four-wave mixing using a split-and-delay line

New, hard x-ray free electron lasers (FEL) produce intense femtosecond-to-attosecond pulses at angstrom wavelengths, giving access to the fundamental spatial and temporal scales of matter. These revolutionary light sources open the door to applying the suite of nonlinear, optical spectroscopy methods at hard x-ray photon energies. Nonlinear spectroscopy with hard x-rays can allow for measuring the coherence properties of short wavelength excitations with atomic specificity and for understanding how high energy excitations couple to other degrees of freedom in atomic, molecular or condensed-phase systems. As a step in this direction, here we present hard x-ray, optical four-wave mixing (4WM) measurements done at 9.8 keV at the split-and-delay line at the x-ray correlation spectroscopy (XCS) hutch of the Linac Coherent Light Source (LCLS). In this work, we create an x-ray transient grating (TG) from a pair of crossing x-ray beams and diffract optical laser pulses at 400 nm from the TG. The key technical advance here is being able to independently vary the delays of the x-ray pulses. Measurements were made in 3 different solid samples: bismuth germinate (BGO), zinc oxide (ZnO) and yttrium aluminum garnet (YAG). The resulting phase-matched, 4WM signal is measured in two different ways: by varying the x-ray, x-ray pulse delay which can reveal both material and light source coherence properties and also by varying the optical laser delay with respect to the x-ray TG to study how the x-ray excitation couples to the optical properties. Although no coherent 4WM signal was seen in these measurements, the absence of this signal gives important information on experimental requirements for detecting this in future work. Also, our laser-delay scans, although not a new measurement, were applied to different materials than in past work and reveal new examples x-ray induced lattice dynamics in solids. This work represents a key step towards extending nonlinear optics and time-resolved spectroscopy into the hard x-ray regime.

47 OTHER INSTRUMENTATION↗

Spectral studies of soft x-ray radiation of laser-produced plasma of various target materials in a wide spectral range

Here, the work is devoted to experimental study of soft X-ray radiation spectra of laser produced plasma in a wide spectral range 5–100 Å at the “Kamerton” facility (GPI) with pulse duration 70 ps, pulse energy 1–5 J, wavelength 0.53 microns at which the laser intensity (power flux density) of 7×10 14 – 3.5×10 15 W/cm 2 was achieved. A spectrograph was used, which had transmission diffraction gratings with a ratio of the elementary gap to the period of the structure of 0.25 and 0.41. Detection was performed on both UV-4 X-ray photo film and Fuji TR fluorescent imaging plate. Solid samples from Al, Si, Ti, Cu, Ta and W were used as targets. The ionization states of the plasma corresponding to various electron temperatures were calculated, which made it possible to estimate the electron temperature by comparison these calculation results with the experimentally obtained spectra. The estimated electron temperature, which depends on the laser pulse energy and the target material, varied within the range of 100–450 eV. To verify the correctness of the temperature estimations obtained by such comparison a numerical simulation of plasma radiation was carried out by the use of PrismSPECT computer program. It was found that the results of this simulation are in a good agreement with estimations on the base of experimentally obtained spectra. The analysis of these spectra showed that tantalum, tungsten or titanium targets are the best candidates among the tested ones for the use of laser produced plasma as a radiation source in the "water window" spectral range (23–44 Å) for applications in biology and medicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low blaze angle grating for fully dispersive x-ray spectroscopy

We demonstrate fabrication of an ultra-low blaze angle (LBA) grating designed for time-resolved spectroscopy in the x-ray region. A blaze angle of 0.12° was achieved by the groove depth reduction process providing a perfect saw-tooth shape of the grooves. The 200 lines/mm LBA grating exhibited high diffraction efficiency at a photon energy of 8 KeV. Use in a spectrometer would open up dispersive x-ray absorption spectroscopy across a wide energy range including the K edges of 3d transition metals, with much greater efficiency than traditional crystal spectrometers.

Voronov, D. L.↗

Manipulation of the orbital angular momentum of soft X-ray beams by consecutive diffractive optics

Production and manipulation of orbital angular momentum (OAM) of coherent soft X-ray beams is demonstrated utilizing consecutive diffractive optics. OAM addition is observed upon passing the beam through consecutive fork gratings. Here, the OAM of the beam was found to be decoupled from its spin angular momentum (SAM). Practical implementation of angular momentum control by consecutive devices in the X-ray regime opens new experimental opportunities, such as direct measurement of the beam’s OAM without resorting to phase-sensitive techniques, including holography. OAM analyzers utilizing fork gratings can be used to characterize the beams produced by synchrotron and free electron lasers sources; they can also be used in scattering experiments.

36 MATERIALS SCIENCE↗

Pattern-enhanced Resonant Soft X-ray Scattering for Operando monitoring of electrochemical solid-liquid interfaces

Unveiling interfaces at sub-nanometer scales is essential for advancing the understanding of complex chemical transformations. However, characterizing solid-liquid interfaces with high dimensional sensitivity and temporal resolution remains challenging, due to their dynamic nature and inaccessibility by conventional probes. Here we present an approach, Pattern-enhanced Resonant Soft X-ray Scattering, to overcome the challenges. Rooted in a “sample-as-optics” philosophy, this technique utilizes precisely engineered line-grating nanopatterns to modulate near-field X-ray illumination, coherently enhancing scattering signals from the line-gratings. We implement the method using Ni line-grating nanopatterns in electrochemical water oxidation. The periodic nanostructures serve as diffractive optical elements to reveal the Ni oxidation gradients and structural dynamics at the electrode-electrolyte interfaces. Finite-element simulations corroborate the observed trends by modeling variations in compositions and structures during electrocatalysis. Through integrating advanced sample design with coherent wave nature of soft X-rays, our approach opens accessible pathways to operando exploring chemical evolution and sub-nanometer dimensional variations simultaneously in electrochemical systems. This non-destructive method is efficient and element-specific, making it valuable for probing chemical and dimensional dynamics with appropriate modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale strain wave generation by a piezoelectric grating from polar vortices

Nanostructures formed by spontaneously broken symmetry have provided new ways to manipulate quantum states. Specifically, topological structures with periodic spatial ordering, such as polar vortices and skyrmions, can be ideal hosts for creating engineered responses in both spatial and frequency domains. So far, however, only a few examples of such hierarchical engineering have been reported in the literature. Here we demonstrate that the spatially modulated piezoelectric response of a polar vortex structure can create strain waves with a characteristic nanoscale wavefront. Using time-resolved pump–probe resonant X-ray scattering and diffraction measurements, coupled with dynamical phase-field simulations, we show that the piezoelectric modulation of the spontaneously formed polar vortex crystal functions as an acoustic diffraction grating. This system converts incoming laterally uniform strain waves into outgoing waves with a characteristic sub-terahertz frequency, driven by an intrinsic excitation of the polar vortex crystal. Moreover, our phase-field simulations suggest that the dynamic mechanical displacements exhibiting vortex textures are generated from both space- and time-varying piezoelectric responses. Our findings illustrate a new method for generating nanoscale strain waves with unique spatial textures by tuning the hierarchical order of polar topologies to engineer new collective modes, allowing for a wide range of control through the topological lattice.

ferroelectrics↗

Reflection grating fabrication for the Rockets for Extended-source X-ray Spectroscopy

Abstract The Rockets for Extended-source X-ray Spectroscopy (tREXS) grating spectrograph uses modules of reflection gratings to collect spectroscopic data from extended astronomical sources of soft X-rays. Two blazed master gratings were produced on silicon substrates with electron-beam lithography (EBL) and complementary nanofabrication processes that include KOH etching. Substrate-conformal imprint lithography (SCIL) was then used to create 191 replicas of the two grating masters for use in the flight instrument. Diffraction efficiency was measured for several replica gratings, which achieve a peak of$$ \varvec{>} $$ > 70% absolute efficiency near 0.22 keV and an average of$$ \varvec{\approx } $$ ≈ 50% absolute efficiency across the measured band, from 0.18 – 0.8 keV. Here we detail the nanofabrication of the grating masters, including the EBL parameters and tREXS-specific fabrication considerations, and the SCIL replication process used to generate the final instrument gratings. A discussion of grating characterization and areas for future improvement is also presented.

Astronomy & Astrophysics↗

One-dimensional neutron diffraction from layered graphite: Reciprocal space structure and grating behavior

In this work we report observations of one-dimensional neutron diffraction from highly oriented pyrolytic graphite (HOPG), where the scattering angle varies continuously with incident angle following classical grating-like behavior. The 2D polycrystalline structure of HOPG—with highly aligned layers along the 𝑐 axis but random in-plane rotations—creates planes of scattering intensity in reciprocal space at 𝑄 𝑐 =𝑛⁢(2⁢𝜋/𝑑) where 𝑑=3.35Å is the interlayer spacing. As the Ewald sphere sweeps through reciprocal space during sample rotation, it continuously intersects these planes, producing the observed angular dispersion. We observe both first-order (𝑛=1) and second-order (𝑛=2) diffraction at conventional scattering angles (25°–70°), with peak positions that remain temperature-independent between 10 K and 294 K and follow quantitative agreement with momentum conservation 𝑄 𝑐 =𝑘⁢[sin⁡𝜓−sin⁡𝜓 𝑓 ]=𝑛⁢(2⁢𝜋/𝑑). X-ray diffraction under similar conditions shows no comparable behavior, confirming that sharp nuclear-vacuum contrast is essential. While diffraction intensities are weak (∼10 −6 of Bragg peaks), the observations demonstrate how the interplay of atomic-scale periodicity, nuclear contrast, and structural disorder enables observation of continuous diffraction curves at thermal neutron wavelengths, illustrating how HOPG's unique microstructure determines its scattering properties beyond conventional Bragg diffraction.

2-dimensional systems↗

Single-shot measurements of shaped XUV FEL pulses with frequency-resolved optical gating

The ability to control the amplitude and phase of extreme ultraviolet (XUV) and X-ray free-electron laser (FEL) pulses can allow for the extension of optical techniques, such as multidimensional spectroscopy or coherent control, to higher photon energies, for probing and controlling core electronic transitions. However, this requires the ability to make single-shot, and complete, electric field measurements of potentially complex FEL pulses, in order to develop, and verify, pulse shaping strategies. Here, we present direct, single-shot measurements of XUV pulses generated under special operating configurations for producing specific pulse shapes from a laser-seeded XUV FEL. To do this, we built upon our past work using transient grating (TG) cross correlation frequency-resolved optical gating (FROG), where an optical reference pulse is diffracted from an XUV TG produced by a pair of interfering FEL pulses. The resulting nonlinear signal versus frequency and delay, i.e., the FROG trace, contains the electric field of the FEL pulse. The FEL pulse electric field is reconstructed from the FROG trace using a phase retrieval algorithm. Here we confirmed three different pulse shaping strategies for generating chirped, double and multiple FEL pulses by tuning the seed laser and FEL parameters and measuring the resulting shaped FEL pulses with TG XFROG. This work paves the way for generating on-demand pulse shapes with a seeded FEL by improving the characterization of FEL pulses, for transform-limited to more complex shapes.

Elverson, Francesca↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗