Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray microcalorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Discovery of Powerful Multivelocity Ultrafast Outflows in the Starburst Merger Galaxy IRAS 05189–2524 with XRISM

We observed the X-ray-bright ultraluminous infrared galaxy IRAS 05189−2524 with XRISM during its performance verification phase. The unprecedented energy resolution of the onboard X-ray microcalorimeter revealed complex spectral features at ∼7–9 keV, which can be interpreted as blueshifted Fe XXV/XXVI absorption lines with various velocity dispersions, originating from ultrafast outflow (UFO) components with multiple bulk velocities of ∼0.076c, ∼0.101c, and ∼0.143c. In addition, a broad Fe–K emission line was detected around ∼7 keV, forming a P Cygni profile together with the absorption lines. The onboard X-ray CCD camera revealed a 0.4–12 keV broadband spectrum characterized by a neutrally absorbed power-law continuum with a photon index of ∼2.3 and intrinsic flare-like variability on timescales of ∼10 ks, both of which are likely associated with near-Eddington accretion. We also found potential variability of the UFO parameters on a timescale of ∼140 ks. Using these properties, we propose new constraints on the outflow structure and suggest the presence of multiple outflowing regions on scales of about tens to 100 Schwarzschild radii, located within roughly 2000 Schwarzschild radii. Since both the estimated momentum and energy outflow rates of the UFOs exceed those of galactic molecular outflows, our results indicate that powerful, multivelocity UFOs are already well developed during a short-lived evolutionary phase following a major galaxy merger, characterized by intense starburst activity and likely preceding the quasar phase. This system is expected to evolve into a quasar, sustaining strong UFO activity and suppressing star formation in the host galaxy.

Astronomy and AstroPhysics↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

Benchmark of the Fe xvv 𝓡 ratio in photoionized plasma during eclipse of Centaurus X-3 with XRISM/Resolve

The $\mathcal {R}$ ratio is a useful diagnostic of the X-ray emitting astrophysical plasmas and is defined as the intensity ratio of the forbidden over the inter-combination lines in the K$\alpha$ line complex of He-like ions. The value is altered by excitation processes (electron impact or UV photoexcitation) from the metastable upper level of the forbidden line, thereby constraining the electron density or UV field intensity. The diagnostic has been applied mostly in electron density constraints in collisionally ionized plasmas using low-Z elements, as was originally proposed for the Sun (Gabriel & Jordan, 1969a, MNRAS, 145, 241), but it can also be used in photoionized plasmas. To make use of this diagnostic, we need to know its value in the limit of no excitation of metastables ($\mathcal {R}_{0}$), which depends on the element, how the plasmas are formed, how the lines are propagated, and the spectral resolution affecting line blending principally with satellite lines from Li-like ions. We benchmark $\mathcal {R}_0$ for photoionized plasmas by comparing calculations using radiative transfer codes and observation data taken with the Resolve X-ray microcalorimeter onboard XRISM. We use the Fe xxv He$\alpha$ line complex of the photo-ionized plasma in Centaurus X-3 observed during eclipse, in which the plasma is expected to be in the limit of no metastable excitation. The measured $\mathcal {R} = 0.65 \pm 0.08$ is consistent with the value calculated using xstar for the plasma parameters derived from other line ratios of the spectrum. We conclude that the $\mathcal {R}$ ratio diagnostic can be used for high-Z elements such as Fe in photoionized plasmas, which has wide applications in plasmas around compact objects at various scales.

X-rays: binaries↗

High-spectral-resolution X-Ray Observations of the Evolved Supermassive Stellar Binary System η Carinae: Fe K α Band Profile Revealed with XRISM

The supermassive binary system, η Carinae, is experiencing enormous wind-driven mass loss at a rate unparalleled in the rest of the Galaxy. Their wind–wind collision (WWC) continuously produces shock heated, X-ray-emitting plasmas. The XRISM X-ray observatory observed the system in 2023 and 2024 when the X-ray emission began to increase toward periastron passage in 2025. This paper reports unprecedentedly high-resolution X-ray spectra in the Fe Kα band between 6.2 and 7.1 keV, obtained with the Resolve X-ray microcalorimeter. The hydrogen-like (Lyα) and helium-like (Heα) lines reveal three velocity components. Two of them are broadened with maximum velocities of 2000–3000 km s −1 , likely originating from the postshock companion wind. The other is relatively narrow, with a Gaussian broadening of only ∼290 km s −1 in 1σ, which may originate from the postshock companion wind at the WWC stagnation point or penetrating the primary wind. The Fe fluorescent lines exhibit a moderate blueshift and broadening with velocities at 100–200 km s −1 , consistent with the primary wind’s velocity field. The spectra also confirm a Compton shoulder of the Heα line complex for the first time. Both fluorescing and scattering spectral profiles indicate that the binary system is seen from the companion side during these observations. The flux ratio of the Compton-scattering emission to the fluorescent line suggests substantial hydrogen depletion of the primary wind, expected from CNO-cycled hydrogen nuclear fusion gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗