Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NTD-GE Based Microcalorimeter Performance

Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the primary broadening source. We mention our strategy for finding a suitable solution to this problem and describe briefly a technology for building arrays of these calorimeters.

Bandler, Simon↗

Imaging X-ray spectrometer

An X-ray spectrometer for providing imaging and energy resolution of an X-ray source is described. This spectrometer is comprised of a thick silicon wafer having an embedded matrix or grid of aluminum completely through the wafer fabricated, for example, by thermal migration. The aluminum matrix defines the walls of a rectangular array of silicon X-ray detector cells or pixels. A thermally diffused aluminum electrode is also formed centrally through each of the silicon cells with biasing means being connected to the aluminum cell walls and causes lateral charge carrier depletion between the cell walls so that incident X-ray energy causes a photoelectric reaction within the silicon producing collectible charge carriers in the form of electrons which are collected and used for imaging.

Grant, P. A.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and so forth. These data can immediately distinguish sedimentary from igneous rocks, for example, and can thus eliminate geochemical or mineral ambiguities arising, say between arkose and granite. It would be important to know if the clay being analyzed was part of a uniform varve deposit laid down in a quiescent lake, or the matrix of a megabreccia diamictite deposited as a catastrophic impact ejecta blanket. The unique design of the instrument, which combines Debye-Scherrer geometry with elements of standard goniometry, negates the need for sample preparation of any kind, and thus negates the need for power-hungry and mechanically-complex sampling systems that would have to chip, crush, sieve, and mount the sample for x-ray analysis. Instead, the instrument is simply rested on the sample surface of interest (like a hand lens); the device can interrogate rough rock surfaces, coarse granular material, or fine rock flour. A breadboard version of the instrument has been deployed from the robotic arm of the Marsokhod rover in field trials at NASA Ames, where large vesicular boulders were x-rayed to demonstrate the functionality of the instrument design, and the ability of such a device to comply with constraints imposed by a roving platform. Currently under development is a flight prototype concept of this instrument that will weigh 0.3 kg, using about 4500 J of energy per sample analysis. It requires about 5 min. for XRD analysis, and about 30 min. for XRF interrogation. Its small mass and rugged design make it ideal for deployment on small rovers of the type currently envisaged for the exploration of Mars (e.g., Sojourner-scale platforms). The design utilizes a monolithic P-N junction photodiode pixel array for XRD, a Si PIN photodiode/avalanche photodiode system for XRF, and an endoscopic imaging camera system unobtrusively embedded between the detectors and the x-ray source (the endoscope with its board-mounted camera can be adapted for IR light in addition to visible wavelenths. A rugged, miniature (7 cu cm) x-ray source for the instrument has already been breadboarded.

Marshall, J.↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

Fabrication of Pop-up Detector Arrays on Si Wafers

High sensitivity is a basic requirement for a new generation of thermal detectors. To meet the requirement, close-packed, two-dimensional silicon detector arrays have been developed in NASA Goddard Space Flight Center. The goal of the task is to fabricate detector arrays configured with thermal detectors such as infrared bolometers and x-ray calorimeters to use in space fliGht missions. This paper focuses on the fabrication and the mechanical testing of detector arrays in a 0.2 mm pixel size, the smallest pop-up detectors being developed so far. These array structures, nicknamed "PUDS" for "Pop-Up Detectors", are fabricated on I pm thick, single-crystal, silicon membranes. Their designs have been refined so we can utilize the flexibility of thin silicon films by actually folding the silicon membranes to 90 degrees in order to obtain close-packed two-dimensional arrays. The PUD elements consist of a detector platform and two legs for mechanical support while also serving as electrical and thermal paths. Torsion bars and cantilevers connecting the detector platform to the legs provide additional flexures for strain relief. Using micro-electromechanical structure (MEMS) fabrication techniques, including photolithography, anisotropic chemical etching, reactive-ion etching, and laser dicing, we have fabricated PLTD detector arrays of fourteen designs with a variation of four parameters including cantilever length, torsion bar length and width, and leg length. Folding tests were conducted to test mechanical stress distribution for the array structures. We obtained folding yields and selected optimum design parameters to reach minimal stress levels. Computer simulation was also employed to verify mechanical behaviors of PUDs in the folding process. In addition, scanning electron microscopy was utilized to examine the flatness of detectors and the alignment of detector pixels in arrays. The fabrication of thermistors and heaters on the pop-up detectors is under way, preparing us for the next step of the experiment, the thermal test.

Li, Mary J.↗

Extra-solar astronomy with a 2.4 m normal incidence X-ray telescope at 0.1 arcsec resolution

The advantages and disadvantages for astrophysical observations of a normal incidence X-ray telescope are considered. The baseline configuration is for a 2.4 meter diameter mirror operating at 0.23-0.28 keV with a CCD detector having a pixel size equivalent to 0.1 arcsec. This resolution enables X-ray images to be made comparable to those of Space Telescope in the optical and to those of the Very Large Array in the radio for a large number of sources. Specific examples cover essentially the entire range of astrophysics.

Elvis, M.↗

Fabrication of an X-Ray Imaging Detector

X-ray detector array yields mosaic image of object emitting 1- to 30-keV range fabricated from n-doped silicon wafer. In proposed fabrication technique, thin walls of diffused n+ dopant divide wafer into pixels of rectangular cross section, each containing central electrode of thermally migrated p-type metal. This pnn+ arrangement reduces leakage current by preventing transistor action caused by pnp structure of earlier version.

Alcorn, G. E.↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Laboratory Astrophysics Using a Spare XRS Microcalorimeter

The XRS instrument on Astro-E is a fully self-contained microcalorimeter x-ray instrument capable of acquiring optimally filtering, and characterizing events for 32 independent pixels. With the launch of the Astro-E spacecraft, a full flight spare detector system has been integrated into a laboratory cryostat for use on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory. The detector system contains a microcalorimeter array with 32 instrumented pixels heat sunk to 60 mK using an adiabatic demagnetization refrio,erator. The instrument has a composite resolution of 8eV at 1 keV and 12eV at 6 keV with a minimum of 95% quantum efficiency. This will allow high spectral resolution, broadband observations of collisionally excited plasmas which are produced in the EBIT experiment. Unique to our instrument are exceptionally well characterized 1000 Angstrom thick aluminum on polyimide infrared blocking filters. The detailed transmission function including the edc,e fine structure of these filters has been measured in our laboratory using an erect field grating spectrometer. This will allow the instrument to perform the first broadband absolute flux measurements with the EBIT instrument. The instrument performance as well as the results of preliminary measurements will be discussed. Work performed under the auspices of the U.S. D.o.E. by Lawrence Livermore National Laboratory under contract W-7405-ENG-48 and was supported by the NASA High Energy Astrophysics Supporting Research and Technology Program.

Audley, M. Damian↗

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗

Multianode microchannel array detectors for Space Shuttle imaging applications

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric, photoncounting array detectors that have been developed and qualified specifically for use in space. MAMA detectors with formats as large as 256 x 1024 pixels are now in use or under construction for a variety of imaging and tracking applications. These photo-emissive detectors can be operated in a windowless configuration at extreme ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. The construction and modes-of-operation of the MAMA detectors are briefly described and the scientific objectives of a number of sounding rocket and Space Shuttle instruments utilizing these detectors are outlined. Performance characteristics of the MAMA detectors that are of fundamental importance for operation in the Space Shuttle environment are described and compared with those of the photo-conductive array detectors such as the CCDs and CIDs.

Timothy, J. G.↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

Photon-counting array detectors for space and ground-based studies at ultraviolet and vacuum ultraviolet /VUV/ wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric photon-counting array detectors, with formats as large as (256 x 1024)-pixels that can be operated in a windowless configuration at vacuum ultraviolet (VUV) and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. This paper describes the construction and modes of operation of (1 x 1024)-pixel and (24 x 1024)-pixel MAMA detector systems that are being built and qualified for use in sounding-rocket spectrometers for solar and stellar observations at wavelengths below 1300 A. The performance characteristics of the MAMA detectors at ultraviolet and VUV wavelengths are also described.

Timothy, J. G.↗

Preliminary Performance of CdZnTe Imaging Detector Prototypes

The promise of good energy and spatial resolution coupled with high efficiency and near-room-temperature operation has fuelled a large International effort to develop Cadmium-Zinc-Telluride (CdZnTe) for the hard-x-ray region. We present here preliminary results from our development of small-pixel imaging arrays fabricated on 5x5x1-mm and 5x5x2-mm spectroscopy and discriminator-grade material. Each array has 16 (4x4) 0.65-mm gold readout pads on a 0.75-mm pitch, with each pad connected to a discrete preamplifier via a pulse-welded gold wire. Each array is mounted on a 3-stage Peltier cooler and housed in an ion-pump-evacuated housing which also contains a hybrid micro-assembly for the 16 channels of electronics. We have investigated the energy resolution and approximate photopeak efficiency for each pixel at several energies and have used an ultra-fine beam x-ray generator to probe the performance at the pixel boundaries. Both arrays gave similar results, and at an optimum temperature of -20 C we achieved between 2 and 3% FWHM energy resolution at 60 keV and around 15% at 5.9 keV. We found that all the charge was contained within 1 pixel until very close to the pixels edge, where it would start to be shared with its neighbor. Even between pixels, all the charge would be appropriately shared with no apparently loss of efficiency or resolution. Full details of these measurements will be presented, together with their implications for future imaging-spectroscopy applications.

Ramsey, B.↗