At least 19 records

Oxygen liquefaction and zero-loss storage system

This paper presents an alternative concept that employs existing technologies and off-the-shelf components to liquefy gaseous oxygen from an in-situ propellant production (ISPP) unit and to store the liquid oxygen without boil-off loss. A primary goal is to minimize active components with a secondary goal of designing the active component in a protected or failure-free environment. The resulting design requires only one active component, a compressor operating in a closed and consequently more protected system. The design avoids pumps as active components by employing cryopumping for gaseous oxygen (GOX) and gravity transfer for liquid oxygen (LOX).

F. N. Lin↗

Experimental Results of Integrated Refrigeration and Storage System Testing

Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

Notardonato, W. U.↗

Integrated Ground Operations Demonstration for Responsive Space Access

The NASA Advanced Exploration Systems (AES) program has a three year project to develop and demonstrate technologies to fundamentally change the way ground servicing activities support future access to space architectures. The AES Integrated Ground Operation Demonstration Units (IGODU) project has created two test beds for investigating and maturing two key elements of spaceport processing activities. The first is the GODU Integrated Refrigeration and Storage test bed that is demonstrating zero-loss storage of liquid hydrogen propellants and studying the storage and transfer of densified propellants. The second activity is the GODU Autonomous Control test bed that is implementing health management technologies and autonomous control capability of the propellant loading process to reduce the standing army of experts historically needed to ensure safe propellant loading operations. This presentation will give an overview of the activities at the Kennedy Space Center on these two test beds and its potential impact on future access to space programs.

ground operational support system↗

Ground Operations Demonstration Unit for Liquid Hydrogen (GODU LH2)

When the technology associated with zero loss storage and transfer is implemented, NASA can reduce the LH2 losses and procurement costs by up to 30 compared to historical Shuttle numbers. This return on investment is based on the mission manifest and commodity use. LH2 densification can provide improved launch vehicle ascent performance by minimizing the size of the LH2 tanks or storing more mass of propellant in the given tank volume.

zero loss storage↗

Ground Operations Demonstration Unit for Liquid Hydrogen Initial Test Results

NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite major technology advances in the field of cryogenics. NASA loses approximately 50% of the hydrogen purchased because of a continuous heat leak into ground and flight vessels, transient chill down of warm cryogenic equipment, liquid bleeds, and vent losses. NASA Kennedy Space Center (KSC) needs to develop energy-efficient cryogenic ground systems to minimize propellant losses, simplify operations, and reduce cost associated with hydrogen usage. The GODU LH2 project has designed, assembled, and started testing of a prototype storage and distribution system for liquid hydrogen that represents an advanced end-to-end cryogenic propellant system for a ground launch complex. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The system is unique because it uses an integrated refrigeration and storage system (IRAS) to control the state of the fluid. This paper will present and discuss the results of the initial phase of testing of the GODU LH2 system.

liquefaction↗

ASME Section VIII Recertification of a 33,000 Gallon Vacuum-jacketed LH2 Storage Vessel for Densified Hydrogen Testing at NASA Kennedy Space Center

The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) has been developed at NASA Kennedy Space Center in Florida. GODU-LH2 has three main objectives: zero-loss storage and transfer, liquefaction, and densification of liquid hydrogen. A cryogenic refrigerator has been integrated into an existing, previously certified, 33,000 gallon vacuum-jacketed storage vessel built by Minnesota Valley Engineering in 1991 for the Titan program. The dewar has an inner diameter of 9.5 and a length of 71.5; original design temperature and pressure ranges are -423 F to 100 F and 0 to 95 psig respectively. During densification operations the liquid temperature will be decreased below the normal boiling point by the refrigerator, and consequently the pressure inside the inner vessel will be sub-atmospheric. These new operational conditions rendered the original certification invalid, so an effort was undertaken to recertify the tank to the new pressure and temperature requirements (-12.7 to 95 psig and -433 F to 100 F respectively) per ASME Boiler and Pressure Vessel Code, Section VIII, Division 1. This paper will discuss the unique design, analysis and implementation issues encountered during the vessel recertification process.

Liquefaction↗

Final Test Results for the Ground Operations Demonstration Unit for Liquid Hydrogen

Described herein is a comprehensive project—a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 liter liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.

Zero Boil Off↗

Integrated Refrigeration and Storage for Advanced Liquid Hydrogen Operations

NASA has used liquefied hydrogen (LH2) on a large scale since the beginning of the space program as fuel for the Centaur and Apollo upper stages, and more recently to feed the three space shuttle main engines. The LH2 systems currently in place at the Kennedy Space Center (KSC) launch pads are aging and inefficient compared to the state-of-the-art. Therefore, the need exists to explore advanced technologies and operations that can drive commodity costs down, and provide increased capabilities. The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) was developed at KSC to pursue these goals by demonstrating active thermal control of the propellant state by direct removal of heat using a cryocooler. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The key technology challenge was efficiently integrating the cryogenic refrigerator into the LH2 storage tank. A Linde LR1620 Brayton cycle refrigerator is used to produce up to 900W cooling at 20K, circulating approximately 22 g/s gaseous helium through the hydrogen via approximately 300 m of heat exchanger tubing. The GODU-LH2 system is fully operational, and is currently under test. This paper will discuss the design features of the refrigerator and storage system, as well as the current test results.

Liquefaction↗

Rocket Propulsion (RP) 21 Steering Committee Meeting - NASA Spacecraft Propulsion Update

Lander Tech is three separate but synergistic efforts: Lunar CATALYST (Lunar Cargo Transportation and Landing by Soft Touchdown) Support U.S. industry led robotic lunar lander development via three public-private efforts. Support U.S. industry led robotic lunar lander development via three public-private partnerships. Infuse or transfer landing technologies into these public private partnerships. Advanced Exploration Systems-Automated Propellant Loading (APL) -Integrated Ground Operations. Demonstrate LH2 zero loss storage, loading and transfer operations via testing on a large scale in a relevant launch vehicle servicing environment. (KSC, GRC). Game Changing Technology-20 Kelvin -20 Watt Cryocooler Development of a Reverse Turbo-Brayton Cryocooler operating at 20 Kelvin with 20 Watts of refrigeration lift.

Propellant↗

Cryogenic Propellant Long-term Storage With Zero Boil-off

Significant boil-off losses of cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and large tanks. The zero boil-off (ZBO) concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The potential mass reductions with the ZBO concept are Substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The cryo-cooler with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 30-40 day period. Tests will be conducted at multiple fill levels and various mixer operational cycles to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper. analytical models for heat flows through the MHTB tank, cryo-cooler performance. and spraybar performance will be presented.

Hedayat, A.↗

Cryogenic Propellant Long-Term Storage With Zero Boil-Off

Significant boil-off losses from cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and larger tanks. The potential propellant mass loss reductions with the Zero Boil-off (ZBO) concept are substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The ZBO concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The cryo-cooler is interfaced with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen (LH2) is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 20-30 day period. Tests will be conducted at multiple fill levels to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper the test set-up and test procedures are presented.

Hedayat, Ali↗

NASA Team Develops a Test Article to Demonstrate “Zero Boil-Off” Storage of Liquid Hydrogen via Cryocoolers and a Two-Stage Cooling Approach

Funded by NASA’s Technology Demonstration Mission Program and managed by the Cryogenic Fluid Management Portfolio Project, a NASA team is developing a test article to demonstrate the “zero boil-off” storage of liquid hydrogen using active cooling (cryocoolers) and a two-stage cooling approach. The current state of the art for storage of liquid hydrogen on-orbit is on the order of hours while future missions may require storage for months or even years. To enable such extended storage durations, “near zero” propellant loss, or “zero boil-off”, must be achieved. This may be accomplished with the implementation of “near zero” leakage components, a high performing suite of passive technologies to minimize the environmental heat loads, and active cooling via cryocoolers to intercept and remove heat from the propellant tanks and associated structure. Of course, with any cryogenic vehicle and mission, a mass and power trade should be conducted to determine if it is indeed feasible to carry the additional dry mass associated with active cooling, or if one could simply carry additional propellants to accommodate propellant loss which is typically not an option for a long duration mission.

Hydrogen Storage↗

Mars 2024/2026 Pathfinder Mission: Mars Architectures, Systems, and Technologies for Exploration and Resources Project

Integrate In Situ Resource Utilization (ISRU) sub-systems and examine advanced capabilities and technologies to verify Mars 2024 Forward architecture precursor pathfinder options: Integrated spacecraft/surface infrastructure fluid architecture: propulsion, power, life support center dot Power system feed and propellant scavenging from propulsion system center dot High quality oxygen for life support and EVA Fluid/cryogenic zero-loss transfer and long-term storage center dot Rapid depot-to-rover/spacecraft center dot Slow ISRU plant-to-ascent vehicle Integration of ISRU consumable production center dot Oxygen only from Mars atmosphere carbon dioxide center dot Oxygen, fuel, water, from extraterrestrial soil/regolith Test bed to evaluate long duration life, operations, maintenance on hardware, sensors, and autonomy

Technology Portfolio System↗

Zero-Boiloff Cryogenic Storage Cryocooler Integration Test

Developments in NASA Glenn Research Center's Centaur work have led to an exciting new cryogenic storage concept being considered for future NASA space missions. With long-duration cryogenic storage, propellants will boil off because of the environmental heating of the tank. To accommodate these losses, extra propellant is required along with larger propellant tanks. Analyses of space transportation concepts show that spacetransfer cryogenic stages with the zero boiloff (ZBO) cryogenic storage concept reduce the stage mass for missions longer than approximately 45 days in low Earth orbit. The ZBO system consists of an active cryocooling system using a cryocooler in addition to traditional passive thermal insulation. Engineers at Glenn analyzed, designed, built, and bench tested a heat exchanger and integration hardware for a large-scale ZBO demonstration for the NASA Marshall Space Flight Center. The heat exchanger, which transfers the heat that enters the tank from the fluid to the cryocooler, must limit the temperature difference across it to limit the cryocooler size and power requirements. With a low temperature difference, the system efficiency is improved. For that temperature difference to be reduced, the thermal conductivity must be as high as possible at liquid hydrogen temperatures, around 25 K (-248 C). In addition, it is important for the heat exchanger to be welded to a stainless steel flange and have enough strength to accommodate piping stress. High-conductivity copper was selected and fabricated, then integrated with the stainless steel piping tee as shown in the cutaway representation. Literature showed that this conductivity might range from 2 to 100 W/cm/K but that is was likely to be around 13 W/cm/K. Unexpectedly, this conductivity was measured to be 23 W/cm/K, which limited the temperature increase along the heat exchanger to just 2 K. This limited temperature increase, compared with the predicted difference of 3.5 K, improves the overall system efficiency by 7.4 percent and limits the expected integration losses to a projected 4 percent with a flight design for liquid hydrogen storage. These results improve the cryocooler integration concept by allowing the cryocooler to operate at a lower input power, or by potentially permitting a smaller cryocooler to be selected.

Plachta, David W.↗

Mechanical capacitor

A new energy storage system (the mechanical capacitor), using a spokeless magnetically levitated composite ring rotor, is described and design formulas for sizing the components are presented. This new system is configured around a permanent magnet (flux biased) suspension which has active servo control in the radial direction and passive control in the axial direction. The storage ring is used as a moving rotor and electronic commutation of the stationary armature coils is proposed. There is no mechanical contact with the rotating spokeless ring; therefore, long life and near zero rundown losses are projected. A 7-kW h system is sized to demonstrate feasibility. A literature review of flywheel energy storage systems is also presented and general formulas are developed for comparing rotor geometries.

Kirk, J. A.↗

Ground- versus spaced-based orbital transfer vehicle

A space based orbital transfer vehicle (SBOTV) and ground based OTV's (GBOTV) are compared for debris protection, space based OTV maintenance provisions, flight performance, onorbit refueling, and launch and return operations. Debris protection has a severe impact on the SBOTV, while the penalty for the GBOTV is much less severe. A key technology issue is the protection capability of composite materials. Onorbit maintenance is critical for SBOTV. Reduction of losses during the various transfers is th maine problem with refueling a SBOTV. Zero-g propellant storage and transfer is an important technology area for SBOTV. A reusable shroud must be developed to return GBOTV's if a Shuttle derivative vehicle is used. The advantage of space basing lies in more efficient use of the launch vehicle. Since most of the mass going to LEO is OTV propellant, and the launches to deliver the SBOTV propellant are generally mass limited, substantially fewer launches are required to support the SBOTV.

Rehder, J.↗

Study of the generator/motor operation of induction machines in a high frequency link space power system

Static power conversion systems have traditionally utilized dc current or voltage source links for converting power from one ac or dc form to another since it readily achieves the temporary energy storage required to decouple the input from the output. Such links, however, result in bulky dc capacitors and/or inductors and lead to relatively high losses in the converters due to stresses on the semiconductor switches. The feasibility of utilizing a high frequency sinusoidal voltage link to accomplish the energy storage and decoupling function is examined. In particular, a type of resonant six pulse bridge interface converter is proposed which utilizes zero voltage switching principles to minimize switching losses and uses an easy to implement technique for pulse density modulation to control the amplitude, frequency, and the waveshape of the synthesized low frequency voltage or current. Adaptation of the proposed topology for power conversion to single-phase ac and dc voltage or current outputs is shown to be straight forward. The feasibility of the proposed power circuit and control technique for both active and passive loads are verified by means of simulation and experiment.

Lipo, Thomas A.↗

Long term cryogenic storage system integration

Investigations have revealed significant increases in performance when a reliquefier and solar shield in conjunction with a zero-gravity vapor vent system are utilized. Application of a reliquefier and solar shield in long term deep space missions may effect a 60% reduction in propellant loss, compared to that associated with the vapor vent system only. Significant improvements in storage system performance are possible for low earth orbit applicatons; for the typical system that was evaluated, system performance gains were realized for mission durations exceeding 7 days. Spherical solar shields are generally not competitive for low earth orbit applications.

Stonemetz, R. E.↗