Thermal Performance of Common Bulk-Fill Cryogenic Insulation Materials in Helium and Hydrogen Background Gases

Maritime shipping of vast quantities of liquid hydrogen (LH 2 ) will be necessary to facilitate a global hydrogen ecosystem; with some studies estimating volumes up to 172,000 m 3 for individual tanker ships, and requiring stationary storage tanks at terminals of 50,000 m 3 to 100,000 m 3 —ten to fifteen times larger than the current largest tank, located at launch pad B at NASA Kennedy Space Center (KSC). Such a radical scale-up will push the boundary of traditional, vacuum-insulated tank designs. Hence, a potential need exists for non-vacuum solutions, which necessitates exploring the thermal performance of insulation materials in non-condensable background gasses at LH 2 temperatures, namely helium and hydrogen. Testing of two bulk-fill insulation materials common to large LH 2 storage tanks, perlite and glass bubbles, in helium and hydrogen was recently conducted by the Cryogenics Test Laboratory at KSC using the Cryostat-100 liquid nitrogen boiloff calorimeter per the ASTM C1774 standard methodology. Effective thermal conductivity (k e ) and heat flux (q) results for each insulation/gas combination are presented across the full vacuum range, as well as thermal profiles through the insulation thickness between 78 K and 293 K.

A M Swanger↗

Final Test Results for the Ground Operations Demonstration Unit for Liquid Hydrogen

Described herein is a comprehensive project—a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 liter liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.

Zero Boil Off↗

Energy Efficient Large-Scale Storage of Liquid Hydrogen

The world’s largest liquid hydrogen storage tanks were constructed in the mid-1960sat the NASA Kennedy Space Center. These two vacuum-jacketed, perlite powder insulated tanks, still in service today, have 3,200 m3 of useable capacity. In 2018, construction began on an additional storage tank at Launch Complex 39B. This new tank will give an additional storage capacity of 4,700 m3 for a total on-site storage capacity of roughly 8,000 m3. NASA’s new Space Launch System (SLS) heavy lift rocket for the Artemis program includes an LH2tank that makes up the bulk of the vehicle, holding 2,033 m3 of LH2 in its 8.4-m diameter by40-m height. The new storage tank includes two new energy-efficient technologies: a glass bubbles insulation system in lieu of perlite, and an Integrated Refrigeration and Storage (IRAS)heat exchanger for controlled storage capability. The evacuated glass bubbles insulation system is based on the prior two decades of research to prove the thermal performance benefits as well as the mechanical and vacuum integrity; and has been shown to reduce LH2 boiloff by 46%versus perlite in field demonstrations. The IRAS capability is centered on a heat exchanger system that is built within the inner vessel to reject heat from the bulk liquid through the future implementation of an external helium refrigerator. Controlled storage via IRAS, when fully implemented, will provide full control of the ullage pressure, zero boiloff, and even production of densified LH2 pending its adoption on future launch vehicles. The design basics are described along with main construction and testing processes involved. The key features of the new technology items and implications on simplified operations and long-term energy savings are addressed

cryogenics↗

Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

Mechanically connected fluid joints are virtually unavoidable in complex cryogenic system designs. In the case of spacecraft, the performance of these joints is critical to mission success. This is especially true for long-duration space missions where even very low leak rates can eventually lead to significant propellant losses or failure of vital cryogenic cooling systems. NASA has recently undertaken an effort to quantify the leak rate of Vacuum Coupling Radiation (VCR) fittings over the temperature range from ambient to 20 K, both before and after exposure to a launch vibration profile. A test apparatus employing a cryocooler and a calibrated helium mass spectrometer was developed, validated, and used to obtain quantifiable leak rates at a fitting test pressure of 31 bar (450 psig). Three different fitting sizes were tested, 25.4 mm (¼ inch), 12.7 mm (½ inch), and 6.35 mm (1 inch) and two gasket materials, stainless steel, and silver-plated nickel. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles/measurement tests, followed by a launch vibration test profile at ambient temperature, and then two additional cryogenic thermal cycles/measurement tests. The design and development of the test apparatus, and test data are presented and discussed in detail.

G J Tamasy↗

Preliminary experimental studies into the storage capacity of cryogenic hydrogen in aerogel blanket materials

The abundance and diversity of hydrogen applications necessitates continued and accelerated research into advanced storage technologies. Traditionally, hydrogen has been stored as either a high-pressure, warm gas; or a low-pressure, cryogenic liquid. Methods such as cryo-supercritical and cryo-adsorbed have been explored, but are not yet mainstream. Cryo-adsorbed is attractive because higher storage densities at higher temperatures than liquid may be achieved. Recently NASA, in partnership with Eta Space, Southwest Research Institute, the University of Central Florida, and Air Liquide, have been exploring the use of inexpensive, commercially available silica aerogel blanket materials for cryo-adsorbed hydrogen storage. Unlike most adsorbents, aerogel blanket is not a powder, but a robust, composite material that can be formed into complex shapes to aid in more efficient storage system designs, and has already been proven to uptake large quantities of fluids such as nitrogen and oxygen. Recent experimental efforts into the uptake of low-pressure hydrogen gas at 77 K, and liquid hydrogen at normal boiling point (NBP) will be discussed. Although preliminary in nature, the test results are promising, showing up to a 49% increase in storage density at 77 K over the gas alone, and greater than a one-to-one volume equivalency with NBP LH 2 .

A M Swanger↗

Development of a Portable Stand-Alone 20 K Brayton Cycle Helium Refrigeration System

From 2012 to 2015, NASA funded development of the Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) at Kennedy Space Center that scaled up and matured Integrated Refrigeration and Storage (IRAS) technology. IRAS involves the integration of an external helium refrigeration system with a cryogenic storage tank via an internal heat exchanger and allows advanced operations such as zero boiloff and densification of the liquid. The refrigeration system employed for GODU-LH2 was a Linde LR1620 piston-Brayton cycle machine with an RSX helium compressor. The GODU-LH2 system was installed in two separate shipping containers—one housing the cold-box, compressor, and gas management hardware, and the other the water chiller unit—with 480 VAC and 120 VAC electrical power fed from external hardware at the test site, and data capture and controls achieved using four different, independent software packages. From 2017 to 2019, in support of a densified hydrogen loading test program, the entire system was repackaged into a single, 40’ (12 m) shipping container, including the refrigeration system, water chiller, and electrical power distribution hardware, and controls were consolidated into a single Allen Bradley PanelView. Details regarding the design, build-out, and testing of the system will be presented and discussed.

W F Reaves↗

Vacuum Pump-Down of the Annular Insulation Space for Large Field-Erected Liquid Hydrogen Storage Tanks

Insulation systems are critical to liquid hydrogen storage tank performance. Tanks in the capacity range of 100 to 1,000 m 3 are typically shop built and designed with high-vacuum (HV) multi-layer insulation (MLI), whereas storage vessels larger than 1,000 m 3 are typically field-erected and supplied with bulk fill insulation working at moderate vacuum (MV) levels (1-100 millitorr). For large, field-erected vessels, two types of bulk fill insulation typically used: perlite and hollow glass microspheres (glass bubbles). Selection of either material is driven by a tradeoff between CAPEX and OPEX, such as the material and construction cost versus operating thermal performance and maintenance. In either case, the vacuum level needed to achieve optimum performance is likely to drive the field testing and commissioning portion of the construction schedule. A primary goal of this paper is to present practical experience and data for warm vacuum pressure (WVP) and cold vacuum pressure (CVP) levels. Recommended WVP levels needed prior to cooldown consider both perlite powder and glass bubbles. Pumping time expected to achieve target vacuum levels, considering a variety of factors, is also discussed. Recommendations for a standard practice in vacuum-insulated tank commissioning are based on historical NASA data, and those collected during recent projects.

A M Swanger↗

Development and Testing of a Lab-Scale Electrochemical Refrigerator

Eta Space and NASA have been developing a lab-scale electrochemical hydrogen refrigerator (ECHR) capable of providing isothermal heat exchange for applications in the 20-Kelvin range. The cryocooler utilizes an electrochemical compressor paired with Joule-Thomson expansion to cool the hydrogen working fluid down to its saturation point within a purpose-built cold box. The use of electrochemical compression allows the cycle to operate with no moving parts presenting several key advantages for a variety of applications. Testing of the integrated system occurred in Eta Space’s cryogenic test facility where the system was able to achieve and maintain saturated temperatures at low pressure. Results of this test campaign demonstrate the feasibility of the ECHR concept in practice.