Search NASA⌕ Search

NASA NTRS · 20210018293

Energy Efficient Large-Scale Storage of Liquid Hydrogen

Abstract

The world’s largest liquid hydrogen storage tanks were constructed in the mid-1960sat the NASA Kennedy Space Center. These two vacuum-jacketed, perlite powder insulated tanks, still in service today, have 3,200 m3 of useable capacity. In 2018, construction began on an additional storage tank at Launch Complex 39B. This new tank will give an additional storage capacity of 4,700 m3 for a total on-site storage capacity of roughly 8,000 m3. NASA’s new Space Launch System (SLS) heavy lift rocket for the Artemis program includes an LH2tank that makes up the bulk of the vehicle, holding 2,033 m3 of LH2 in its 8.4-m diameter by40-m height. The new storage tank includes two new energy-efficient technologies: a glass bubbles insulation system in lieu of perlite, and an Integrated Refrigeration and Storage (IRAS)heat exchanger for controlled storage capability. The evacuated glass bubbles insulation system is based on the prior two decades of research to prove the thermal performance benefits as well as the mechanical and vacuum integrity; and has been shown to reduce LH2 boiloff by 46%versus perlite in field demonstrations. The IRAS capability is centered on a heat exchanger system that is built within the inner vessel to reject heat from the bulk liquid through the future implementation of an external helium refrigerator. Controlled storage via IRAS, when fully implemented, will provide full control of the ullage pressure, zero boiloff, and even production of densified LH2 pending its adoption on future launch vehicles. The design basics are described along with main construction and testing processes involved. The key features of the new technology items and implications on simplified operations and long-term energy savings are addressed

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J E Fesmire, A M Swanger, J A Jacobson, W U Notardonato. Energy Efficient Large-Scale Storage of Liquid Hydrogen. https://ntrs.nasa.gov/citations/20210018293

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Exergetic design and analysis of a freeze-out heat exchanger for helium purification

The freeze-out purification process is very effective in removing moisture contamination and can be utilised for purification of helium gas in cryogenic applications. A process model for a freeze-out helium purifier (up to 30 g/s of contaminated helium at 10 ppmv) with a coiled finned-tube heat exchanger is developed. Furthermore, an extensive 1st and 2nd law (exergy) analysis is carried out and the exergetically optimal heat exchanger configuration (diameter and number of flow passes) for a given heat exchanger surface area ranging from 42.5 m 2 to 57.5 m 2 are found.

cryogenics↗

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-TemperatureTanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellant is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of the effect of spacecraft propellant system parameters on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the general thermodynamic principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran implementation. Comparisons between the model results and test data are discussed, as well as sensitivity of the condensation rate to various parameters.

cryogenics↗