Search NASA⌕ Search

Engineering topics

Adams, B. W.

Publications and source records attributed to Adams, B. W..

First Light from Beam Neutrinos on an LAPPD in ANNIE,

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) probes the physics of neutrino-nucleus interactions in a gadolinium-loaded water (Gd-water) target while serving as a flexible testbed for advanced next-generation optical neutrino detection technologies. These advanced technologies include novel detection media (particularly Gd-water and hybrid Cherenkov-scintillation through water-based liquid scintillator) and novel photosensors. In this paper we demonstrate the first implementation of a fully-integrated setup for Large Area Picosecond PhotoDetectors (LAPPDs) in a neutrino experiment. Details are presented regarding the design, commissioning, and deployment of an LAPPD and the supporting systems. We also present the first neutrino interactions ever observed with an LAPPD.

FOS: Physical sciences↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Air-transfer production method for large-area picosecond photodetectors

We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCPPMT) using the “air-transfer” assembly process developed with single LAPPD TM modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and of hermetically sealing the large-perimeter window–body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume and have shown that the micro-channel plates recover their functionality after cathode synthesis. These steps inform a design for a multi-module batch facility employing dual nested low-vacuum and ultra-high-vacuum systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.

47 OTHER INSTRUMENTATION↗

Performance of Large Area Picosecond Photo-Detectors (LAPPD TM )

In this study, we report on performance results achieved for recently produced LAPPDs - largest commercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to 1 0 7 , low dark noise rates (~100 Hz/cm 2 at a gain of 6 ∙ 1 0 6 ), single photoelectron (PE) timing resolution of ~50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE (Back et al., 2017), WATCHMAN (Askins et al., 2015), DUNE (Capozzi et al., 2018), particle collider experiments (e.g. EIC (Accardi et al., 2016), neutrinoless double-beta decay experiments (e.g. THEIA (Fischer et al., 2018)), medical and nuclear non-proliferation applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

Developments in time-resolved x-ray research at APS beamline 7ID

The 7ID beamline of the Advanced Photon Source (APS) is dedicated to time-resolved research using x-ray imaging, scattering, and spectroscopy techniques. Time resolution is achieved via gated detectors and/or mechanical choppers in conjunction with the time structure of the x-ray beam. Three experimental hutches allow for a wide variety of experimental setups. Major areas of research include atomic, molecular, and optical physics; chemistry; condensed matter physics in the bulk, thin film, and surface regimes; and fluid-spray dynamics. Recent developments in facilities at 7ID include a high-power, high-repetition-rate picosecond laser to complement the 1 kHz ultrafast laser. For the ultrafast laser, a newly commissioned optical parametric amplifier provides pump wavelength from 0.2 to 15 µm with energy per pulse up to 200 µJ. A nanodiffraction station has also been commissioned, using Fresnel zone-plate optics to achieve a focused x-ray spot of 300 nm. This nanoprobe is not only used to spatially resolve the evolution of small features in samples after optical excitation, but also has been combined with an intense THz source to study material response under ultrafast electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pump–probe spectrometer for measuring x-ray induced strain

A hard x-ray pump–probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. In conclusion, we present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing Characteristics of Large Area Picosecond Photodetectors

The LAPPD Collaboration was formed to develop ultralast large-area imaging photodetectors based on new methods for fabricating microchannel plates (MCPs). In this paper we characterize the time response using a pulsed, sub picosecond laser. We observe single photoelectron time resolutions of a 20 cm x 20 cm MCP consistently below 70 ps, spatial resolutions of roughly 500 pm, and median gains higher than 10(7). The RMS measured at one particular point on an LAPPD detector is 58 ps, with in of 47 ps. The differential time resolution between the signal reaching the two ends of the delay line anode is measured to be 5.1 ps for large signals, with an asymptotic limit falling below 2 ps as noise-over-signal approaches zero.

LAPPD↗

X-Ray Comb Generation from Nuclear-Resonance-Stabilized X-Ray Free-Electron Laser Oscillator for Fundamental Physics and Precision Metrology

An x-ray free-electron laser oscillator (XFELO) is a next-generation x-ray source, similar to free-electron laser oscillators at VUV and longer wavelengths but using crystals as high-reflectivity x-ray mirrors. Each output pulse from an XFELO is fully coherent with high spectral purity. The temporal coherence length can further be increased drastically, from picoseconds to microseconds or even longer, by phase-locking successive XFELO output pulses, using the narrow nuclear resonance lines of nuclei such as Fe-57 as a reference. We show that the phase fluctuation due to the seismic activities is controllable and that due to spontaneous emission is small. The fluctuation of electron-bunch spacing contributes mainly to the envelope fluctuation but not to the phase fluctuation. By counting the number of standing-wave maxima formed by the output of the nuclear-resonance-stabilized (NRS) XFELO over an optically known length, the wavelength of the nuclear resonance can be accurately measured, possibly leading to a new length or frequency standard at x-ray wavelengths. A NRS-XFELO will be an ideal source for experimental x-ray quantum optics as well as other fundamental physics. The technique can be refined for other, narrower resonances such as Ta-181 or Sc-45.

Adams, B. W.↗