Search NASA⌕ Search

Engineering topics

Anderson, Mark

Publications and source records attributed to Anderson, Mark.

At least 55 records · Page 3

Using optical fibers to examine thermal mixing of liquid sodium in a pool-type geometry

Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.

42 ENGINEERING↗

Experimental study for critical heat flux in 2x2 rod bundles at high pressure conditions

Critical heat flux (CHF) phenomena has been a topic of study for over fifty years yet remains a serious concern across industries and especially in water-cooled nuclear reactor design. CHF data in the high-pressure range is limited, and the effects of bundle geometry and non-uniform heat flux profile are challenging to quantify. In this study, CHF experiments were performed in upward flowing water in a 2 × 2 rod bundle with a cosine profile heat flux. Data were collected between 16.5 and 18 MPa at two mass flux conditions with three inlet subcooling conditions. Under these conditions, average CHF was shown to decrease with increasing pressure. However, pressure had less of an effect than decreasing the inlet subcooling or the mass flux, both of which reduce the CHF value considerably. Of interest, correlations that have been developed for lower pressure continued to predict CHF occurrences with moderate accuracy outside their ranges of validity. Nearly all predicted values were within 20% of experimental values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Efficient 1-D Thermal Stratification Model for Pool-Type Sodium-Cooled Fast Reactors

Investigating thermal stratification in the upper plenum of a sodium fast reactor (SFR) is presently a technology gap in SFR safety analysis. Understanding thermal stratification will promote safe operation of the SFR before its commercial deployment. Stratified layers of liquid sodium with a large vertical temperature gradient could be established in the upper plenum of an SFR during a down-power or a loss-of-flow transient. These stratified layers are unstable and could result in uncertainties for the core safety of an SFR. In order to predict the occurrence of the thermal stratification efficiently, we developed a one-dimensional (1-D) transport model to estimate the temperature profile of the ambient fluid in the upper plenum. This model demands much less computational effort than computational fluid dynamics (CFD) codes and provides calculations with higher fidelity than historical system-level codes. Two flow conditions were considered separately in the current study depending on if in-vessel components are presented in the upper plenum. For the condition where in-vessel components, specifically the upper internal structure, are presented, we assumed that the impinging sodium was evenly dispersed in the ambient fluid within the distance between the bottom of the in-vessel component and the jet inlet surface. For the condition where no in-vessel components are presented, we assumed that the impinging sodium was evenly dispersed in the ambient fluid within the jet length, which was determined through data-driven trainings. The newly developed 1-D model showed similar performance with the CFD model in both cases. However, due to the assumption of flat profiles of the impinging jet axial dispersion rate, nonnegligible discrepancies between the 1-D prediction and the measured data were observed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Corrosion and Mechanical Performance of Grade 92 Ferritic-Martensitic Steel After Exposure to Supercritical Carbon Dioxide

Grade 92 ferritic-martensitic steel is a candidate alloy for medium temperature (< 550 °C) components for the supercritical carbon dioxide (s-CO 2 ) Brayton cycle. 1000 hours exposures were performed on base and welded material in s-CO 2 at temperatures of 450 °C or 550 °C and compared to samples aged in Ar at 550 °C. Both s-CO 2 exposures resulted in a duplex oxide growth and carburization, with 450 °C exhibiting carburization in a power law diffusion profile up to a depth of 200-250 µm, while 550 °C showed a linear profile up to a depth of 100 µm. The different profiles indicate much slower precipitation and coarsening of carbides at the lower temperature, allowing carbon to diffuse deeper into the material. However, 450 °C produced improved mechanical properties while 550 °C produced deteriorated properties. This was due to the higher density of carbon near the metal–oxide interface which leads to significant carbide coarsening and, subsequently, crack initiation and early failure. Finally, additional exposure at 450 °C is predicted to increase deposited carbon, but further study would be needed to understand if and when carburization will produce a negative mechanical effect.

36 MATERIALS SCIENCE↗

A Critical Review of Fluoride Salt Heat Transfer

Interest in molten salts for next-generation nuclear reactors has given rise increasing design work over the last several years. Much of this builds off historic heat transfer experiments like those of the Molten Salt Reactor Program; yet, there is no comprehensive report covering experimental heat transfer in these fluids. This paper attempts to pull together all available reports on fluoride salt heat transfer to aid further research in this area. The data largely support the hypothesis that molten salt heat transfer will be easy to predict so long as salt properties are well known. Our work does not show any consistent indications of resistive films, entrained gases, or radiation heat transfer, but other unknowns are present. In addition to salt properties, these include unusual mass transfer and transition flow conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mars 2020 sample caching system contamination: how to clean hardware and keep it clean

The Mars 2020 Rover will have the capability to collect and cache samples for potential Mars sample return. Specifically, the sample caching system (SCS) is designed for coring Mars samples and acquiring regolith samples as well as handling, sealing and caching on Mars. As the potential first Martian samples that could be returned to Earth, assuring low levels of terrestrial contamination is of the utmost concern. In developing the SCS, the project prioritizes limiting sample contamination in organic, inorganic and biological areas. The focus of this paper is on the strategies being implemented to clean the assemble the sampling hardware to meet and maintain stringent contamination requirements.

Rainen, Richard↗

Organic and inorganic contamination control approaches for return sample investigation on Mars 2020

The Mars 2020 Rover mission will have the capability to collect and cache samples for potential Mars sample return. Specifically, the sample caching system (SCS) is designed for coring Mars samples and acquiring regolith samples as well as handling, sealing and caching on Mars. As the potential first Martian samples that could be returned to Earth, assuring low levels of terrestrial contamination is of the utmost concern. In developing the SCS, the project prioritizes limiting sample contamination in organic, inorganic and biological areas. The focus of this paper is on the strategies being implemented to limit terrestrial organic and inorganic contamination in the samples.

Steltzner, Adam↗

Mitigation of Attentional Tunneling in the Flight Deck Using a Spatial Auditory Display

The role of attentional bias to a specific form of information, e.g., visual versus aural instructions, was evaluated to address the issue of attentional fixation (i.e., "cognitive tunneling") in the flight deck. A method of mitigating attentional tunneling using a spatial auditory display was evaluated in the presence and absence of a biasing factor. Data were gathered for participant recognition, accuracy and response times to aural and visual instructions under different conditions of distractor stimuli. Results showed a significant main effect for target acquisition with the use of spatial audio techniques. No significant main effects or interactions were found for target acquisition timing. Target acquisition was not affected by a "gaming score" biasing factor associated with the distractor tasks.

readback errors↗

Spacecraft Contamination Control Challenges for Space Missions with Organic Compound Detection Capabilities and for Potential Sample Return

Spacecraft contamination control is critical to space exploration missions with organic compound detection capabilities, and also for missions targeting acquisition of samples for potential return to Earth. Significant challenges are being addressed and resolved in the design of current flight projects and conceptual mission studies at JPL. These challenges extend to both orbiting spacecraft, as well as landed missions, for future missions to Mars and Europa, and potential missions to Titan and Enceladus. Contamination control during all phases of a mission, from preliminary design through operation, is fundamental to ensure that organic compounds of terrestrial origin are controlled to ensure successful completion of science objectives. This paper examines contamination control challenges specific to landed missions (which include sample acquisition, encapsulation, caching, potential sample return, and UV instruments), and orbiting missions (modeling interactions between the spacecraft and local exospheres and plumes).

Sylvia, Margarite↗

Temperature Control with Two Parallel Small Loop Heat Pipes for GLM Program

The concept of temperature control of an electronic component using a single Loop Heat Pipe (LHP) is well established for Aerospace applications. Using two LHPs is often desirable for redundancy/reliability reasons or for increasing the overall heat source-sink thermal conductance. This effort elaborates on temperature controlling operation of a thermal system that includes two small ammonia LHPs thermally coupled together at the evaporator end as well as at the condenser end and operating "in parallel". A transient model of the LHP system was developed on the Thermal Desktop (TradeMark) platform to understand some fundamental details of such parallel operation of the two LHPs. Extensive thermal-vacuum testing was conducted with two thermally coupled LHPs operating simultaneously as well as with only one LHP operating at a time. This paper outlines the temperature control procedures for two LHPs operating simultaneously with widely varying sink temperatures. The test data obtained during the thermal-vacuum testing, with both LHPs running simultaneously in comparison with only one LHP operating at a time, are presented with detailed explanations.

0000↗

Analytical Chemistry Laboratory

The Analytical Chemistry and Material Development Group maintains a capability in chemical analysis, materials R&D failure analysis and contamination control. The uniquely qualified staff and facility support the needs of flight projects, science instrument development and various technical tasks, as well as Cal Tech.

chemical analysis↗

Surface-Enhanced X-Ray Fluorescence

Surface-enhanced x-ray fluorescence (SEn-XRF) spectroscopy is a form of surface- enhanced spectroscopy that was conceived as a means of obtaining greater sensitivity in x-ray fluorescence (XRF) spectroscopy. As such, SEn-XRF spectroscopy joins the ranks of such other, longer-wavelength surface-enhanced spectroscopies as those based on surface-enhanced Raman scattering (SERS), surface-enhanced resonance Raman scattering (SERRS), and surfaceenhanced infrared Raman absorption (SEIRA), which have been described in previous NASA Tech Briefs articles. XRF spectroscopy has been used in analytical chemistry for determining the elemental compositions of small samples. XRF spectroscopy is rapid and quantitative and has been applied to a variety of metal and mineralogical samples. The main drawback of XRF spectroscopy as practiced heretofore is that sensitivity has not been as high as required for some applications. In SEn-XRF as in the other surface-enhanced spectroscopies, one exploits several interacting near-field phenomena, occurring on nanotextured surfaces, that give rise to local concentrations of incident far-field illumination. In this case, the far-field illumination comes from an x-ray source. Depending on the chemical composition and the geometry of a given nanotextured surface, these phenomena could include the lightning-rod effect (concentration of electric fields at the sharpest points on needlelike surface features), surface plasmon resonances, and grazing incidence geometric effects. In the far field, the observable effect of these phenomena is an increase in the intensity of the spectrum of interest - in this case, the x-ray fluorescence spectrum of chemical elements of interest that may be present within a surface layer at distances no more than a few nanometers from the surface.

Anderson, Mark↗

Supercritical CO2 Cleaning for Planetary Protection and Contamination Control

We have designed and built a prototype Supercritical CO? Cleaning (SCC) system at JPL. The key features of the system are: 1) the parts inside a high-pressure vessel can be rotated at high speeds; 2) the same thermodynamic condition is maintained during First-In First-Out flushing to keep solvent power constant; and 3) the boil-off during decompression is induced in a separate vessel downstream. Our goal is to demonstrate SCC's ability to remove trace amounts of microbial and organic contaminants down to parts per billion levels from spacecraft material surfaces for future astrobiology missions. The initial cleaning test results showed that SCC can achieve cleanliness levels of 0.01 microgram/cm(sup 2) or less for hydrophobic contaminants such as dioctyl phthalate and silicone and it is less effective in the removal and inactivation of the hydrophilic bacterial spores as expected. However, with the use of a polar co-solvent, the efficacy may improve dramatically. The same results were obtained using liquid CO?. This opens up the possibility of using subcritical cleaning conditions, which may prove to be more compatible with certain spacecraft hardware.

Lin, Ying↗

Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

Fluorescence↗

Microfluidics, Chromatography, and Atomic-Force Microscopy

A Raman-and-atomic-force microscope (RAFM) has been shown to be capable of performing several liquid-transfer and sensory functions essential for the operation of a microfluidic laboratory on a chip that would be used to perform rapid, sensitive chromatographic and spectro-chemical analyses of unprecedentedly small quantities of liquids. The most novel aspect of this development lies in the exploitation of capillary and shear effects at the atomic-force-microscope (AFM) tip to produce shear-driven flow of liquids along open microchannels of a microfluidic device. The RAFM can also be used to perform such functions as imaging liquids in microchannels; removing liquid samples from channels for very sensitive, tip-localized spectrochemical analyses; measuring a quantity of liquid adhering to the tip; and dip-pen deposition from a chromatographic device. A commercial Raman-spectroscopy system and a commercial AFM were integrated to make the RAFM so as to be able to perform simultaneous topographical AFM imaging and surface-enhanced Raman spectroscopy (SERS) at the AFM tip. The Raman-spectroscopy system includes a Raman microprobe attached to an optical microscope, the translation stage of which is modified to accommodate the AFM head. The Raman laser excitation beam, which is aimed at the AFM tip, has a wavelength of 785 nm and a diameter of about 5 m, and its power is adjustable up to 10 mW. The AFM is coated with gold to enable tip-localized SERS.

Anderson, Mark↗

Nanostructures Exploit Hybrid-Polariton Resonances

Nanostructured devices that exploit the hybrid-polariton resonances arising from coupling among photons, phonons, and plasmons are subjects of research directed toward the development of infrared-spectroscopic sensors for measuring extremely small quantities of molecules of interest. The spectroscopic techniques in question are surface enhanced Raman scattering (SERS) and surface enhanced infrared absorption (SEIRA). An important intermediate goal of this research is to increase the sensitivity achievable by these techniques. The basic idea of the approach being followed in this research is to engineer nanostructured devices and thereby engineer their hybrid-polariton resonances to concentrate infrared radiation incident upon their surfaces in such a manner as to increase the absorption of the radiation for SEIRA and measure the frequency shifts of surface vibrational modes. The underlying hybrid-polariton-resonance concept is best described by reference to experimental devices that have been built and tested to demonstrate the concept. The nanostructure of each such device includes a matrix of silicon carbide particles of approximately 1 micron in diameter that are supported on a potassium bromide (KBr) or poly(tetrafluoroethylene) [PTFE] window. These grains are sputter-coated with gold grains of 40-nm size (see figure). From the perspective of classical electrodynamics, in this nanostructure, that includes a particulate or otherwise rough surface, the electric-field portion of an incident electromagnetic field becomes concentrated on the particles when optical resonance conditions are met. Going beyond the perspective of classical electrodynamics, it can be seen that when the resonance frequencies of surface phonons and surface plasmons overlap, the coupling of the resonances gives rise to an enhanced radiation-absorption or -scattering mechanism. The sizes, shapes, and aggregation of the particles determine the frequencies of the resonances. Hence, the task of designing a nanostructure to exhibit the desired radiation-absorption properties translates, in large part, to selecting particle sizes and shapes to obtain the desired enhanced coupling of energy from photons to plasmons and phonons. To broaden the spectral region(s) of enhanced absorption, one would select a distribution of particle sizes and shapes.

Anderson, Mark↗

Testing Fundamental Properties of Ionic Liquids for Colloid Microthruster Applications

NASA's New Millennium Program is scheduled to test a Disturbance Reduction System (DRS) on Space Technology 7 (ST7) as part of the European Space Agency's (ESA's) LISA Pathfinder Mission in late 2009. Colloid Micronewton Thrusters (CMNTs) will be used to counteract forces, mainly solar photon pressure, that could disturb gravitational reference sensors as part of the DRS. The micronewton thrusters use an ionic liquid, a room temperature molten salt, as propellant. The ionic liquid has a number of unusual properties that have a direct impact on thruster design. One of the most important issues is bubble formation before and during operation, especially during rapid pressure transitions from atmospheric to vacuum conditions. Bubbles have been observed in the feed system causing variations in propellant flow rate that can adversely affect thruster control. Bubbles in the feed system can also increase the likelihood that propellant will spray onto surfaces that can eventually lead to shorting high voltage electrodes. Two approaches, reducing the probability of bubble formation and removing bubbles with a new bubble eliminator device in the flow system, were investigated at Busek Co., Inc. and the Jet Propulsion Laboratory (JPL) to determine the effectiveness of both approaches. Results show that bubble formation is mainly caused by operation at low pressure and volatile contaminants in the propellant coming out of solution. A specification for the maximum tolerable level of contamination has been developed, and procedures for providing system cleanliness have been tested and implemented. The bubble eliminator device has also been tested successfully and has been implemented in recent thruster designs at Busek. This paper focuses on the propellant testing work at JPL, including testing of a breadboard level bubble eliminator device.

bubble formation↗