Search NASASearch

Engineering topics

Aslam, S.

Publications and source records attributed to Aslam, S..

At least 37 records · Page 2

Observation of Strong Nuclear Suppression in Exclusive J/ψ Photoproduction in Au + Au Ultraperipheral Collisions at RHIC

We report a measurement of exclusive J/ψ and ψ⁡(2⁢s) photoproduction in Au+Au ultraperipheral collisions at √s NN = 200 GeV using the STAR detector. For the first time, (i) the ψ⁡(2⁢s) photoproduction in midrapidity at the Relativistic Heavy-Ion Collider has been experimentally measured; (ii) nuclear suppression factors are measured for both the coherent and incoherent J/ψ production. At average photon-nucleon center-of-mass energy of 25.0 GeV, the coherent and incoherent J/ψ cross sections of Au nuclei are found to be 71 ±10% and 36 ±7%, respectively, of that of free protons. The stronger suppression observed in the incoherent production provides a new experimental handle to study the initial-state parton density in heavy nuclei. As a result, data are compared with theoretical models quantitatively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Estimate of background baseline and upper limit on the chiral magnetic effect in isobar collisions at $\sqrt{S_{NN}}$=200 GeV at the BNL Relativistic Heavy Ion Collider

For the search of the chiral magnetic effect (CME), STAR previously presented the results from isobar collisions ($^{96}_{44}$Ru + $^{96}_{44}$Ru, $^{96}_{40}$Zr + $^{96}_{40}$Zr) obtained through a blind analysis. The ratio of results in Ru+Ru to Zr+Zr collisions for the CME-sensitive charge-dependent azimuthal correlator (Δ⁢𝛾), normalized by elliptic anisotropy (𝑣2), was observed to be close to but systematically larger than the inverse multiplicity ratio. The background baseline for the isobar ratio, 𝑌= (Δ⁢𝛾/𝑣2) Ru /(Δ⁢𝛾/𝑣2) Zr , is naively expected to be (1/𝑁) Ru /(1/𝑁) Zr ; however, genuine two- and three-particle correlations are expected to alter it. We estimate the contributions to 𝑌 from those correlations, utilizing both the isobar data and hijing simulations. After including those contributions, we arrive at a final background baseline for 𝑌, which is consistent with the isobar data. Here, we extract an upper limit for the CME fraction in the Δ⁢𝛾 measurement of approximately 10% at a 95% confidence level on in isobar collisions at $\sqrt{S_{NN}}$=200 GeV, with an expected 15% difference in their squared magnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Upper limit on the chiral magnetic effect in isobar collisions at the Relativistic Heavy-Ion Collider

The chiral magnetic effect (CME) is a phenomenon that arises from the QCD anomaly in the presence of an external magnetic field. The experimental search for its evidence has been one of the key goals of the physics program of the Relativistic Heavy-Ion Collider. The STAR Collaboration has previously presented the results of a blind analysis of isobar collisions ( Ru 44 96 + Ru 44 96 , Zr 40 96 + Zr 40 96 ) in the search for the CME. The isobar ratio ( Y ) of CME-sensitive observable, charge separation scaled by elliptic anisotropy, is close to but systematically larger than the inverse multiplicity ratio, the naive background baseline. This indicates the potential existence of a CME signal and the presence of remaining nonflow background due to two- and three-particle correlations, which are different between the isobars. In this postblind analysis, we estimate the contributions from those nonflow correlations as a background baseline to Y , utilizing the isobar data as well as Heavy Ion Jet Interaction Generator simulations. This baseline is found consistent with the isobar ratio measurement, and an upper limit of 10% at 95% confidence level is extracted for the CME fraction in the charge separation measurement in isobar collisions at s NN = 200 GeV. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

The CAESAR New Frontiers Mission: Comet Surface Sample Acquisition and Preservation

NASA recently selected the Comet Astrobiology Exploration Sample Return (CAESAR) mission for Phase A study in the New Frontiers Program. This mission will acquire and return to Earth for laboratory analysis at least 80 g of surface material from the nucleus of comet 67P/Churyumov-Gerasimenko (hereafter 67P). CAESAR will characterize the surface region sampled, preserve the sample in a pristine state, and return evolved volatiles by capturing them in a separate gas reservoir. The system protects both volatile and non-volatile components from contamination or alteration thatwould hamper their scientific analysis. Laboratory analyses of comet samples provide unparalleled knowledge about the presolar history through the initial stages of planet formation to the origin of life.

CAESAR

A Compact, Multi-view Net Flux Radiometer for Future Uranus and Neptune Probes

A Net Flux Radiometer (NFR) is presented that can be included in an atmospheric structure instrument suite for future probe missions to the icy giants Uranus and Neptune. The baseline design has two spectral channels i.e., a solar channel (0.4-to-3.5 m) and a thermal channel (4-to-300 m). The NFR is capable of viewing five distinct viewing angles during the descent. Non-imaging Winston cones with band-pass filters are used for each spectral channel and to define a 5 angular acceptance. Uncooled thermopile detectors are used in each spectral channel and are read out using a custom radiation hard application specific integrated circuit (ASIC). The baseline design can easily be changed to increase the number of detector channels from two to seven.

Aslam, S.

SmallSat Spinning Lander with a Raman Spectrometer Payload for Future Ocean Worlds Exploration Missions

We describe an Evolved Expendable Launch Vehicle Secondary Payload Adapter (ESPA)-class SmallSat spinning lander concept for the exploration of Europa or other Ocean World surfaces to ascertain the potential for life. The spinning lander will be ejected from an ESPA ring from an orbiting or flyby spacecraft and will carry on-board a standoff remote Spatial Heterodyne Raman spectrometer (SHRS) and a time resolved laser induced fluorescence spectrograph (TR-LIFS), and once landed and stationary the instruments will make surface chemical measurements. The SHRS and TR-LIFS have no moving parts have minimal mass and power requirements and will be able to characterize the surface and near-surface chemistry, including complex organic chemistry to constrain the ocean composition.

Ridenoure, R.

Composite Infrared Spectrometer (CIRS) on Cassini

The Cassini spacecraft orbiting Saturn carries the composite infrared spectrometer (CIRS) designed to study thermal emission from Saturn and its rings and moons. CIRS, a Fourier transform spectrometer, is an indispensable part of the payload providing unique measurements and important synergies with the other instruments. It takes full advantage of Cassini's 13-year-long mission and surpasses the capabilities of previous spectrometers on Voyager 1 and 2. The instrument, consisting of two interferometers sharing a telescope and a scan mechanism, covers over a factor of 100 in wavelength in the mid and far infrared. It is used to study temperature, composition, structure, and dynamics of the atmospheres of Jupiter, Saturn, and Titan, the rings of Saturn, and surfaces of the icy moons. CIRS has returned a large volume of scientific results, the culmination of over 30 years of instrument development, operation, data calibration, and analysis. As Cassini and CIRS reach the end of their mission in 2017, we expect that archived spectra will be used by scientists for many years to come.

Jennings, Donald E.

Thermal Radiometer Signal Processing Using Radiation Hard CMOS Application Specific Integrated Circuits for Use in Harsh Planetary Environments

Thermal radiometers such as proposed for the Europa Clipper flyby mission require low noise signal processing for thermal imaging with immunity to Total Ionizing Dose (TID) and Single Event Latchup (SEL). Described is a second generation Multi- Channel Digitizer (MCD2G) Application Specific Integrated Circuit (ASIC) that accurately digitizes up to 40 thermopile pixels with greater than 50 Mrad (Si) immunity TID and 174 MeV-sq cm/mg SEL. The MCD2G ASIC uses Radiation Hardened By Design (RHBD) techniques with a 180 nm CMOS process node.

Focal Plane Assembly

MgB2-Based Bolometer Array for Far Infra-Red Thermal Imaging and Fourier Transform Spectroscopy Applications

The mid-superconducting critical temperature (T(sub c) approximately 39 K) of the simple binary, intermetallic MgB, [1] makes it a very good candidate for the development of the next generation of electrooptical devices (e.g. [2]). In particular, recent advances in thin film deposition teclmiques to attain higb quality polycrystalline thin film MgB, deposited on SiN-Si substrates, with T(sub c) approximately 38K [3] coupled with the low voltage noise performance of the film [4] makes it higbly desirable for the development of moderately cooled bolometer arrays for integration into future space-bourne far infra-red (FIR) spectrometers and thermal mappers for studying the outer planets, their icy moons and other moons of interest in the 17-250 micrometer spectral wavelength range. Presently, commercially available pyroelectric detectors operating at 300 K have specific detectivity, D(*), around 7 x 10(exp 8) to 2 x 10(exp 9) centimeters square root of Hz/W. However, a MgB2 thin film based bolometer using a low-stress (less than 140 MPa) SiN membrane isolated from the substrate by a small thermal conductive link, operating at 38 K, promises to have two orders of magnitude higher specific detectivity [5][6].

Lakew, B.

A Radiation Hardened by Design CMOS ASIC for Thermopile Readouts

A radiation hardened by design (RHBD) mixed-signal application specific integrated circuit (ASIC) has been designed for a thermopile readout for operation in the harsh Jovian orbital environment. The multi-channel digitizer (MCD) ASIC includes 18 low noise amplifier channels which have tunable gain/filtering coefficients, a 16-bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The 18 channels, SDADC and controller were designed to operate with immunity to single event latchup (SEL) and to at least 10 Mrad total ionizing dose (TID). The ASIC also contains a radiation tolerant 16-bit 20 MHz Nyquist ADC for general purpose instrumentation digitizer needs. The ASIC is currently undergoing fabrication in a commercial 180 nm CMOS process. Although this ASIC was designed specifically for the harsh radiation environment of the NASA led JEO mission it is suitable for integration into instrumentation payloads 011 the ESA JUICE mission where the radiation hardness requirements are slightly less stringent.

Quilligan, G.

Towards an Imaging Mid-Infrared Heterodyne Spectrometer

We are developing a concept for a compact, low-mass, low-power, mid-infrared (MIR; 5- 12 microns) imaging heterodyne spectrometer that incorporates fiber optic coupling, Quantum Cascade Laser (QCL) local oscillator, photomixer array, and Radio Frequency Software Defined Readout (RFSDR) for spectral analysis. Planetary Decadal Surveys have highlighted the need for miniaturized, robust, low-mass, and minimal power remote sensing technologies for flight missions. The drive for miniaturization of remote sensing spectroscopy and radiometry techniques has been a continuing process. The advent of MIR fibers, and MEMS techniques for producing waveguides has proven to be an important recent advancement for miniaturization of infrared spectrometers. In conjunction with well-established photonics techniques, the miniaturization of spectrometers is transitioning from classic free space optical systems to waveguide/fiber-based structures for light transport and producing interference effects. By their very nature, these new devices are compact and lightweight. Mercury-Cadmium-Telluride (MCT) and Quantum Well Infrared Photodiodes (QWIP) arrays for heterodyne applications are also being developed. Bulky electronics is another barrier that precluded the extension of heterodyne systems into imaging applications, and our RFSDR will address this aspect.

Hewagama, T.

GaN-Based Detector Enabling Technology for Next Generation Ultraviolet Planetary Missions

The ternary alloy AlN-GaN-InN system provides several distinct advantages for the development of UV detectors for future planetary missions. First, (InN), (GaN) and (AlN) have direct bandgaps 0.8, 3.4 and 6.2 eV, respectively, with corresponding wavelength cutoffs of 1550 nm, 365 nm and 200 nm. Since they are miscible with each other, these nitrides form complete series of indium gallium nitride (In(sub l-x)Ga(sub x)N) and aluminum gallium nitride (Al(sub l-x)Ga(sub x)N) alloys thus allowing the development of detectors with a wavelength cut-off anywhere in this range. For the 2S0-365 nm spectral wavelength range AlGaN detectors can be designed to give a 1000x solar radiation rejection at cut-off wavelength of 325 nm, than can be achieved with Si based detectors. For tailored wavelength cut-offs in the 365-4S0 nm range, InGaN based detectors can be fabricated, which still give 20-40x better solar radiation rejection than Si based detectors. This reduced need for blocking filters greatly increases the Detective Quantum efficiency (DQE) and simplifies the instrument's optical systems. Second, the wide direct bandgap reduces the thermally generated dark current to levels allowing many observations to be performed at room temperature. Third, compared to narrow bandgap materials, wide bandgap semiconductors are significantly more radiation tolerant. Finally, with the use of an (AI, In)GaN array, the overall system cost is reduced by eliminating stringent Si CCD cooling systems. Compared to silicon, GaN based detectors have superior QE based on a direct bandgap and longer absorption lengths in the UV.

Aslam, S.

MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

Lakew, B.

A Near-Infrared and Thermal Imager for Mapping Titan's Surface Features

Approximately 10% of the solar insolation reaches the surface of Titan through atmospheric spectral windows. We will discuss a filter based imaging system for a future Titan orbiter that will exploit these windows mapping surface features, cloud regions, polar storms. In the near-infrared (NIR), two filters (1.28 micrometer and 1.6 micrometer), strategically positioned between CH1 absorption bands, and InSb linear array pixels will explore the solar reflected radiation. We propose to map the mid, infrared (MIR) region with two filters: 9.76 micrometer and 5.88-to-6.06 micrometers with MCT linear arrays. The first will map MIR thermal emission variations due to surface albedo differences in the atmospheric window between gas phase CH3D and C2H4 opacity sources. The latter spans the crossover spectral region where observed radiation transitions from being dominated by thermal emission to solar reflected light component. The passively cooled linear arrays will be incorporated into the focal plane of a light-weight thin film stretched membrane 10 cm telescope. A rad-hard ASIC together with an FPGA will be used for detector pixel readout and detector linear array selection depending on if the field-of-view (FOV) is looking at the day- or night-side of Titan. The instantaneous FOV corresponds to 3.1, 15.6, and 31.2 mrad for the 1, 5, and 10 micrometer channels, respectively. For a 1500 km orbit, a 5 micrometer channel pixel represents a spatial resolution of 91 m, with a FOV that spans 23 kilometers, and Titan is mapped in a push-broom manner as determined by the orbital path. The system mass and power requirements are estimated to be 6 kg and 5 W, respectively. The package is proposed for a polar orbiter with a lifetime matching two Saturn seasons.

Aslam, S.

A Radiation Hard Multi-Channel Digitizer ASIC for Operation in the Harsh Jovian Environment

In 1995, the Galileo spacecraft arrived at Jupiter to conduct follow-up experiments on pathfinder Pioneer and key Voyager discoveries especially at Io, Europa, Ganymede and Callisto. These new observations helped expand our scientific knowledge of the prominent Galilean satellites; studies revealed diversity with respect to their geology, internal structure, evolution and degree of past and present activity. Jupiter's diverse Galilean satellites, of which three are believed to harbor internal oceans, are central to understanding the habitability of icy worlds. Galileo provided for the first time compelling evidence of a near-surface global ocean on Europa. Furthermore, by understanding the Jupiter system and unraveling the history of its evolution from initial formation to the emergence of possible habitats and life, gives insight into how giant planets and their satellite systems form and evolve. Most important, new light is shed on the potential for the emergence and existence of life in icy satellite oceans. In 2009, NASA released a detailed Jupiter Europa Mission Study (EJSM) that proposed an ambitious Flagship Mission to understand more fully the satellites Europa and Ganymede within the context of the Jovian system. Key to EJSM is the NASA led Jupiter Europa Orbiter (JEO) and the ESA led Jupiter Ganymede Orbiter (JGO). JEO and JGO would execute a choreographed exploration of the Jovian system before settling into orbit around Europa and Ganymede, respectively. The National Academies Planetary Decadal Survey, 2011 has listed the NASA-led JEO as the second highest priority mission for the decade 2013-2022, and if chosen it would be launched in 2020 with arrival at Jupiter in 2025. If the JEO mission is not chosen it is anticipated that there will be opportunities in future decadal cycles. Jupiter Orbit Insertion (JOI) begins a 30-month Jovian system tour followed by nine months of science mapping after Europa Orbit Insertion (EOI) in July 2028. The orbiter will ultimately impact the surface of Europa after the mission is completed. The current JEO mission concept includes a range of instruments on the payload, to monitor dynamic phenomena (such as Io's volcanoes and Jupiters atmosphere), map the Jovian magnetosphere and its interactions with the Galilean satellites, and characterize water oceans beneath the ice shells of Europa and Ganymede. The payload includes a low mass (3.7 Kg) and low power (< 5 W) Thermal Instrument (TI) concept for measuring possible warm thermal anomalies on Europa s cold surface caused by recent (< 10,000 years) eruptive activity. Regions of anomalously high heat flow will be identified by thermal mapping using a nadir pointing, push-broom filter radiometer that provides far-IR imagery in two broad band spectral wavelength regions, 8-20 m and 20-100 m, for surface temperature measurements with better than a 2 K accuracy and a spatial resolution of 250 m/pixel obtained from a 100 Km orbit. The temperature accuracy permits a search for elevated temperatures when combined with albedo information. The spatial resolution is sufficient to resolve Europa's larger cracks and ridge axial valleys. In order to accomplish the thermal mapping, the TI uses sensitive thermopile arrays that are readout by a custom designed low-noise Multi-Channel Digitizer (MCD) ASIC that resides very close to the thermopile linear array outputs. Both the thermopile array and the MCD ASIC will need to show full functionality within the harsh Jovian radiation environment, operating at cryogenic temperatures, typically 150 K to 170 K. In the following, a radiation mitigation strategy together with a low risk Radiation-Hardened-By-Design (RHBD) methodology using commercial foundry processes is given for the design and manufacture of a MCD ASIC that will meet this challenge.

Aslam, Shahid

Update on the Fabrication and Performance of 2-D Arrays of Superconducting Magnesium Diboride (MgB2) Thermal Detectors for Outer-Planets Exploration

Detectors with better performance than the current thermopile detectors that operate at room temperature will be needed at the focal plane of far-infrared instruments on future planetary exploration missions. We will present an update on recent results from the 2-D array of MgB2 thermal detectors being currently developed at NASA Goddard. Noise and sensitivity results will be presented and compared to thermal detectors currently in use on planetary missions.

Lakew, Brook

l/f Noise in the Superconducting Transition of a MgB2 Thin Film

The noise voltage spectral density in the superconducting transition of a MgB2 thin film on a SiN-coated Si thick substrate was measured over the frequency range 1 Hz-to-1 KHz. Using established bolometer noise theory the theoretical noise components due to Johnson, 1/f(excess) and phonon noise are modeled to the measured data. It is shown that for the case of a MgB2 thin film in the vicinity of the mid-point of transition, coupled to a heat sink via a fairly high thermal conductance (approximately equal to 10(sup -1) W/K)) that the measured noise voltage spectrum is 1/f limited and exhibits lit dependence with a varying between 0.3 and 0.5 in the measured frequency range. At a video frame rate frequency of 30 Hz the measured noise voltage density in the film is approximately equal to 61 nV /the square root of HZ, using this value an upper limit of electrical NEP approximately equal to 0.67pW / the square root of Hz is implied for a practical MgB2 bolometer operating at 36.1 K.

Lakew, B.