Search NASAβŒ• Search

Engineering topics

Back, A.

Publications and source records attributed to Back, A..

At least 19 records

Neutron detector response modeling in NOvA

Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.

Abubakar, S.β†—

Joint neutrino oscillation analysis from the T2K and NOvA experiments

The landmark discovery that neutrinos have mass and can change type (or flavour) as they propagateβ€”a process called neutrino oscillationβ€”has opened up a rich array of theoretical and experimental questions being actively pursued today. Neutrino oscillation remains the most powerful experimental tool for addressing many of these questions, including whether neutrinos violate charge-parity (CP) symmetry, which has possible connections to the unexplained preponderance of matter over antimatter in the Universe. Oscillation measurements also probe the mass-squared differences between the different neutrino mass states (Ξ”$m^2$), whether there are two light states and a heavier one (normal ordering) or vice versa (inverted ordering), and the structure of neutrino mass and flavour mixing. Here we carry out the first joint analysis of datasets from NOvA and T2K, the two currently operating long-baseline neutrino oscillation experiments (hundreds of kilometres of neutrino travel distance), taking advantage of our complementary experimental designs and setting new constraints on several neutrino sector parameters. This analysis provides new precision on the $Ξ”m_{32}^2$ mass difference, finding $-2.43_{βˆ’0.03}^{+0.04}$ x $10^{-13}$ $\textrm{eV}^2$ in the normal ordering and $-2.43^{+0.03}_{-0.04}$ x $10^{-13}$ $\textrm{eV}^2$ in the inverted ordering, as well as a 3Οƒ interval on Ξ΄ CP of [βˆ’1.38Ο€, 0.30Ο€] in the normal ordering and [βˆ’0.92Ο€, βˆ’0.04Ο€] in the inverted ordering. The data show no strong preference for either mass ordering, but notably, if inverted ordering were assumed true within the three-flavour mixing model, then our results would provide evidence of CP symmetry violation in the lepton sector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Monte Carlo method for constructing confidence intervals with unconstrained and constrained nuisance parameters in the NOvA experiment

Measuring observables to constrain models using maximum-likelihood estimation is fundamental to many physics experiments. Wilks' theorem provides a simple way to construct confidence intervals on model parameters, but it only applies under certain conditions. These conditions, such as nested hypotheses and unbounded parameters, are often violated in neutrino oscillation measurements and other experimental scenarios. Monte Carlo methods can address these issues, albeit at increased computational cost. In the presence of nuisance parameters, however, the best way to implement a Monte Carlo method is ambiguous. Furthermore, this paper documents the method selected by the NOvA experiment, the profile construction. It presents the toy studies that informed the choice of method, details of its implementation, and tests performed to validate it. It also includes some practical considerations which may be of use to others choosing to use the profile construction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DUNE Phase II: scientific opportunities, detector concepts, technological solutions

The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the European Strategy for Particle Physics. While the construction of the DUNE Phase I is well underway, this White Paper focuses on DUNE Phase II planning. DUNE Phase-II consists of a third and fourth far detector (FD) module, an upgraded near detector complex, and an enhanced 2.1 MW beam. The fourth FD module is conceived as a β€œModule of Opportunity”, aimed at expanding the physics opportunities, in addition to supporting the core DUNE science program, with more advanced technologies. This document highlights the increased science opportunities offered by the DUNE Phase II near and far detectors, including long-baseline neutrino oscillation physics, neutrino astrophysics, and physics beyond the standard model. It describes the DUNE Phase II near and far detector technologies and detector design concepts that are currently under consideration. A summary of key R&D goals and prototyping phases needed to realize the Phase II detector technical designs is also provided. DUNE's Phase II detectors, along with the increased beam power, will complete the full scope of DUNE, enabling a multi-decadal program of groundbreaking science with neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV

ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/𝑐 beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 Β± 26 mbarns for the 6 GeV/𝑐 setting and 379 Β± 35 mbarns for the 7 GeV/𝑐 setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Search for 𝐢⁒𝑃-Violating Neutrino Nonstandard Interactions with the NOvA Experiment

This Letter reports a search for charge-parity (𝐢⁒𝑃) symmetry violating nonstandard interactions (NSI) of neutrinos with matter using the NOvA Experiment, and examines their effects on the determination of the standard oscillation parameters. Data from 𝜈 πœ‡ ⁑($\bar{𝜈}$ πœ‡ ) β†’ 𝜈 πœ‡ ⁑($\bar{𝜈}$ πœ‡ ) and 𝜈 πœ‡ ⁑($\bar{𝜈}$ πœ‡ ) β†’ 𝜈 𝑒 ⁑( $\bar{𝜈}$ 𝑒 ) oscillation channels are used to measure the effect of the NSI parameters πœ– π‘’β’πœ‡ and πœ– π‘’β’πœ . With 90% CL the magnitudes of the NSI couplings are constrained to be |πœ– π‘’β’πœ‡ | ≲0.3 and |πœ– π‘’β’πœ | ≲ 0.4. A degeneracy at |πœ– π‘’β’πœ | β‰ˆ 1.8 is reported, and we observe that the presence of NSI limits sensitivity to the standard 𝐢⁒𝑃 phase 𝛿 𝐢⁒𝑃 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the double-differential cross section of muon-neutrino charged-current interactions with low hadronic energy in the NOvA Near Detector

The NOvA collaboration reports cross-section measurements for $\nu_{\mu}$ charged-current interactions with low hadronic energy (maximum kinetic energy of 250 MeV for protons and 175 MeV for pions) in the NOvA Near Detector. The results are presented as a double-differential cross section as a function of the direct observables of the final-state muon kinematics. Results are also presented as a single-differential cross section as a function of the derived square of the four-momentum transfer, $Q^{2}$, and as a function of the derived neutrino energy. The data correspond to an accumulated 8.09$\times10^{20}$ protons-on-target (POT) in the neutrino mode of the NuMI beam, with a narrow band of neutrino energies peaked at 1.8 GeV. The analysis provides a sample of neutrino-nucleus interactions with an enhanced fraction of quasi-elastic and two-particle-two-hole (2p2h) interactions. This enhancement allows quantitative comparisons with various nuclear models. We find strong disagreement between data and theory-based models in various regions of the muon kinematic phase space, especially in the forward muon direction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Expanding neutrino oscillation parameter measurements in NOvA using a Bayesian approach

NOvA is a long-baseline neutrino oscillation experiment that measures oscillations in charged-current Ξ½ ΞΌ β†’ Ξ½ ΞΌ (disappearance) and Ξ½ ΞΌ β†’ Ξ½ e (appearance) channels, and their antineutrino counterparts, using neutrinos of energies around 2 GeV over a distance of 810 km. In this work we reanalyze the dataset first examined in our previous paper [] using an alternative statistical approach based on Bayesian Markov chain Monte Carlo. We measure oscillation parameters consistent with the previous results. We also extend our inferences to include the first NOvA measurements of the reactor mixing angle ΞΈ 13 , where we find 0.071 ≀ sin 2 2 ΞΈ 13 ≀ 0.107 , and the Jarlskog invariant, where we observe no significant preference for the C P -conserving value J = 0 over values favoring C P violation. We use these results to examine the effects of constraints from short-baseline measurements of ΞΈ 13 using antineutrinos from nuclear reactors when making NOvA measurements of ΞΈ 23 . Our long-baseline measurement of ΞΈ 13 is shown to be consistent with the reactor measurements, supporting the general applicability and robustness of the Pontecorvo-Maki-Nakagawa-Sakata framework for neutrino oscillations. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment

A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is to measure the π’ͺ⁑(10) MeV neutrinos produced by a Galactic core-collapse supernova if one should occur during the lifetime of the experiment. The liquid-argon-based detectors planned for DUNE are expected to be uniquely sensitive to the 𝜈 𝑒 component of the supernova flux, enabling a wide variety of physics and astrophysics measurements. A key requirement for a correct interpretation of these measurements is a good understanding of the energy-dependent total cross section 𝜎⁑(𝐸 𝜈 ) for charged-current 𝜈 𝑒 absorption on argon. In the context of a simulated extraction of supernova 𝜈 𝑒 spectral parameters from a toy analysis, we investigate the impact of 𝜎⁑(𝐸 𝜈 ) modeling uncertainties on DUNE’s supernova neutrino physics sensitivity for the first time. We find that the currently large theoretical uncertainties on 𝜎⁑(𝐸 𝜈 ) must be substantially reduced before the πœˆπ‘’ flux parameters can be extracted reliably; in the absence of external constraints, a measurement of the integrated neutrino luminosity with less than 10% bias with DUNE requires 𝜎⁑(𝐸 𝜈 ) to be known to about 5%. The neutrino spectral shape parameters can be known to better than 10% for a 20% uncertainty on the cross-section scale, although they will be sensitive to uncertainties on the shape of 𝜎⁑(𝐸 𝜈 ). A direct measurement of low-energy πœˆπ‘’-argon scattering would be invaluable for improving the theoretical precision to the needed level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from πœˆπ‘’ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Snowmass Neutrino Frontier: DUNE Physics Summary

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of $\delta_{CP}$. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗