Search NASASearch

DOE OSTI · 3686274

Neutron detector response modeling in NOvA

Abstract

Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.

Keep this discovery

BibTeXRIS

Abubakar, S., Acero, M. A., Acharya, B., Adamson, P., Anfimov, N., Antoshkin, A., Arrieta-Diaz, E., Asquith, L., Aurisano, A., Back, A., Balashov, N., Baldi, P., Bambah, B. A., Bannister, E. F., Barros, A., Barrow, J., Bat, A., Bezerra, T. J.C., Bhatnagar, V., Bhuyan, B., Bian, J., Booth, A. C. [Imperial Coll., London], Brahma, B., Bromberg, C., Buchanan, N., Burns, J., Butkevich, A., Catano-Mur, E., Cesar, J. P., Chang, C., Chaudhary, S., Chen, H., Choate, S., Choudhary, B. C., Chow, O. T.K., Christensen, A., Cicala, M. F., Coan, T. E., Contreras, T., Cooleybeck, A., Cremonesi, L. [Imperial Coll., London], Davies, G. S., Derwent, P. F., Dever, K., Djurcic, Z., Dobbs, K., Dueñas Tonguino, D., Dukes, E. C., Dye, A., Ehrlich, R., Ewart, E., Filip, P., Frank, M. J., Gallagher, H. R., Giri, A., Gomes, R. A., Goodman, M. C., Gusmão, A., Habig, A., Hakl, F., Hartnell, J., Hatcher, R., Hays, J. M., He, M., Heller, K., Hewes, V., Himmel, A., Horoho, T. (ORCID:0000000301174814), Huang, X., Huynh, T., Ivanova, A., Kaess, K., Kakorin, I., Kalitkina, A., Kaplan, D. M., Khanam, A., Kirezli, B., Kleykamp, J., Klimov, O., Koerner, L. W., Kolupaeva, L., Kufatty, G., Kumar, A., Kuruppu, C. D., Kus, V., Lackey, T., Lang, K., Lister, A., Liu, J., Lock, J. A., Magill, S., Mann, W. A., Manoharan, M. T., Plata, M. Manrique, Marathe, A., Marshak, M. L., Martinez-Casales, M., Matveev, V., Medhi, A., Mehta, B.. 2026-09-07. Neutron detector response modeling in NOvA. https://www.osti.gov/biblio/3686274

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

Shakeup and shakeoff spectra in the electron capture decay of atomic 7 Be

The most stringent laboratory-based experimental limits on the existence of submegaelectronvolt sterile neutrinos are currently set by decay spectroscopy of radioactive 7 Be embedded into superconducting sensors. The systematic uncertainties are dominated by the modeling of the electron shakeup and shakeoff spectra that are not based on state-of-the-art atomic theory and do not include electron correlations or relativistic effects. We have used the multiconfiguration Dirac-Fock formalism to obtain correlated wave functions ab initio and compute all single and double shake processes in the electron capture decay of atomic 7 Be . The simulations can explain some but not all of the observed spectral features, likely because the wave functions are modified by the Ta sensor material that the 7 Be is embedded into. The new models also show that the 𝐿/𝐾 electron capture ratio of 7 Be in Ta has previously been slightly underestimated revising the previous value of 0.070(7) to a new value of 0.0756(20).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS