Search NASA⌕ Search

Engineering topics

Balakrishna, S.

Publications and source records attributed to Balakrishna, S..

At least 19 records

NASA Common Research Model Test Envelope Extension With Active Sting Damping at NTF

The NASA Common Research Model (CRM) high Reynolds number transonic wind tunnel testing program was established to generate an experimental database for applied Computational Fluid Dynamics (CFD) validation studies. During transonic wind tunnel tests, the CRM encounters large sting vibrations when the angle of attack approaches the second pitching moment break, which can sometimes become divergent. CRM transonic test data analysis suggests that sting divergent oscillations are related to negative net sting damping episodes associated with flow separation instability. The National Transonic Facility (NTF) has been addressing remedies to extend polar testing up to and beyond the second pitching moment break point of the test articles using an active piezoceramic damper system for both ambient and cryogenic temperatures. This paper reviews CRM test results to gain understanding of sting dynamics with a simple model describing the mechanics of a sting-model system and presents the performance of the damper under cryogenic conditions.

Rivers, Melissa B.↗

Effects of Active Sting Damping on Common Research Model Data Quality

Recent tests using the Common Research Model (CRM) at the Langley National Transonic Facility (NTF) and the Ames 11-foot Transonic Wind Tunnel (11' TWT) produced large sets of data that have been used to examine the effects of active damping on transonic tunnel aerodynamic data quality. In particular, large statistically significant sets of repeat data demonstrate that the active damping system had no apparent effect on drag, lift and pitching moment repeatability during warm testing conditions, while simultaneously enabling aerodynamic data to be obtained post stall. A small set of cryogenic (high Reynolds number) repeat data was obtained at the NTF and again showed a negligible effect on data repeatability. However, due to a degradation of control power in the active damping system cryogenically, the ability to obtain test data post-stall was not achieved during cryogenic testing. Additionally, comparisons of data repeatability between NTF and 11-ft TWT CRM data led to further (warm) testing at the NTF which demonstrated that for a modest increase in data sampling time, a 2-3 factor improvement in drag, and pitching moment repeatability was readily achieved not related with the active damping system.

Acheson, Michael J.↗

Analysis of NASA Common Research Model Dynamic Data

Recent NASA Common Research Model (CRM) tests at the Langley National Transonic Facility (NTF) and Ames 11-foot Transonic Wind Tunnel (11-foot TWT) have generated an experimental database for CFD code validation. The database consists of force and moment, surface pressures and wideband wing-root dynamic strain/wing Kulite data from continuous sweep pitch polars. The dynamic data sets, acquired at 12,800 Hz sampling rate, are analyzed in this study to evaluate CRM wing buffet onset and potential CRM wing flow separation.

Balakrishna, S.↗

Recent Enhancements to the National Transonic Facility (Mixed Mode Operations)

The U.S. National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the development of a Mixed-mode of operations that combine Air-mode operations with Nitrogen-mode operations. This implementation and operational results of this new Mixed-mode expands the ambient temperature transonic region of testing beyond the Air-mode limitations at a significantly reduced cost over Nitrogen Mode operation.

Kilgore, W. Allen↗

Recent Enhancements to the National Transonic Facility

The National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the restoration of reliability and improved performance of the heat exchanger systems resulting in the expansion of the NTF air operations envelope. Additionally, results are presented from a continued effort to reduce model dynamics through the use of a new stiffer balance and sting

Kilgore, W. A.↗

Recent Enhancements to the National Transonic Facility

The National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the restoration of reliability and improved performance of the heat exchanger systems resulting in the expansion of the NTF air operations envelope. Additionally, results are presented from a continued effort to reduce model dynamics through the use of a new stiffer balance and sting.

Kilgore, W. A.↗

Reduction of Tunnel Dynamics at the National Transonic Facility (Invited)

This paper describes the results of recent efforts to reduce the tunnel dynamics at the National Transonic Facility. The results presented describe the findings of an extensive data analysis, the proposed solutions to reduce dynamics and the results of implementing these solutions. These results show a 90% reduction in the dynamics around the model support structure and a small impact on reducing model dynamics. Also presented are several continuing efforts to further reduce dynamics.

Kilgore, W. A.↗

Recent National Transonic Facility Test Process Improvements (Invited)

This paper describes the results of two recent process improvements; drag feed-forward Mach number control and simultaneous force/moment and pressure testing, at the National Transonic Facility. These improvements have reduced the duration and cost of testing. The drag feedforward Mach number control reduces the Mach number settling time by using measured model drag in the Mach number control algorithm. Simultaneous force/moment and pressure testing allows simultaneous collection of force/moment and pressure data without sacrificing data quality thereby reducing the overall testing time. Both improvements can be implemented at any wind tunnel. Additionally the NTF is working to develop and implement continuous pitch as a testing option as an additional method to reduce costs and maintain data quality.

Kilgore, W. A.↗

Recent National Transonic Facility Test Process Improvements (Invited)

This paper describes the results of two recent process improvements; drag feed-forward Mach number control and simultaneous force/moment and pressure testing, at the National Transonic Facility. These improvements have reduced the duration and cost of testing. The drag feed-forward Mach number control reduces the Mach number settling time by using measured model drag in the Mach number control algorithm. Simultaneous force/moment and pressure testing allows simultaneous collection of force/moment and pressure data without sacrificing data quality thereby reducing the overall testing time. Both improvements can be implemented at any wind tunnel. Additionally the NTF is working to develop and implement continuous pitch as a testing option as an additional method to reduce costs and maintain data quality.

Kilgore, W. A.↗

Development of a model protection and dynamic response monitoring system for the national transonic facility

A state-of-the-art, computerized mode protection and dynamic response monitoring system has been developed for the NASA Langley Research Center National Transonic Facility (NTF). This report describes the development of the model protection and shutdown system (MPSS). A technical description of the system is given along with discussions on operation and capabilities of the system. Applications of the system to vibration problems are presented to demonstrate the system capabilities, typical applications, versatility, and investment research return derived from the system to date. The system was custom designed for the NTF but can be used at other facilities or for other dynamic measurement/diagnostic applications. Potential commercial uses of the system are described. System capability has been demonstrated for forced response testing and for characterizing and quantifying bias errors for onboard inertial model attitude measurement devices. The system is installed in the NTF control room and has been used successfully for monitoring, recording and analyzing the dynamic response of several model systems tested in the NTF.

Young, Clarence P., Jr.↗

Performance of the 0.3-meter transonic cryogenic tunnel with air, nitrogen, and sulfur hexafluoride media under closed loop automatic control

The NASA Langley 0.3-m Transonic Cryogenic Tunnel was modified in 1994, to operate with any one of the three test gas media viz., air, cryogenic nitrogen gas, or sulfur hexafluoride gas. This document provides the initial test results with respect to the tunnel performance and tunnel control, as a part of the commissioning activities on the microcomputer based controller. The tunnel can provide precise and stable control of temperature to less than or equal to +/- 0.3 K in the range 80-320 K in cyro mode or 300-320 K in air/SF6 mode, pressure to +/- 0.01 psia in the range 15-88 psia and Mach number to +/- O.0015 in the range 0.150 to transonic Mach numbers up to 1.000. A new heat exchanger has been included in the tunnel circuit and is performing adequately. The tunnel airfoil testing benefits considerably by precise control of tunnel states and helps in generating high quality aerodynamic test data from the 0.3-m TCT.

Balakrishna, S.↗

Effects of vibration on inertial wind-tunnel model attitude measurement devices

Results of an experimental study of a wind tunnel model inertial angle-of-attack sensor response to a simulated dynamic environment are presented. The inertial device cannot distinguish between the gravity vector and the centrifugal accelerations associated with wind tunnel model vibration, this situation results in a model attitude measurement bias error. Significant bias error in model attitude measurement was found for the model system tested. The model attitude bias error was found to be vibration mode and amplitude dependent. A first order correction model was developed and used for estimating attitude measurement bias error due to dynamic motion. A method for correcting the output of the model attitude inertial sensor in the presence of model dynamics during on-line wind tunnel operation is proposed.

Young, Clarence P., Jr.↗

A PC-based simulation of the National Transonic Facitity's safety microprocessor

A brief study was undertaken to demonstrate the feasibility of using a state-of-the-art off-the-shelf high speed personal computer for simulating a microprocessor presently used for wind tunnel safety purposes at Langley Research Center's National Transonic Facility (NTF). Currently, there is no active display of tunnel alarm/alert safety information provided to the tunnel operators, but rather such information is periodically recorded on a process monitoring computer printout. This does not provide on-line situational information nor permit rapid identification of safety operational violations which are able to halt tunnel operations. It was therefore decided to simulate the existing algorithms and briefly evaluate a real-time display which could provide both position and trouble shooting information.

Thibodeaux, J. J.↗

A feasibility study of using Langley 0.3-m transonic cryogenic tunnel sidewall boundary-layer removal system for heavy gas testing

This report presents the results of a preliminary study for using the 0.3-m Transonic Cryogenic Tunnel sidewall boundary-layer removal system with heavy gas sulfur hexafluoride as the test medium. It is shown that the drive motor speed/power of the existing system and the additional heat load on the tunnel heat exchanger are the major problems limiting the boundary-layer removal system performance. Overcoming these problems can provide the capability to remove about 1.5 percent of the test section mass flow at Mach number M = 0.8 and about 5 percent at M = 0.25. Previous studies have shown that these boundary-layer mass flow removal rates can reduce the boundary-layer thickness by a factor of two at the model station. Also the effect of upstream boundary-layer removal on the airfoil test data is not likely to be significant under high lifting conditions. Near design conditions, corrections to the test Mach number may be necessary to account for sidewall boundary-layer effects.

Murthy, A. V.↗

Modeling and control study of the NASA 0.3-meter transonic cryogenic tunnel for use with sulfur hexafluoride medium

The NASA Langley 0.3-m Transonic Cryogenic Tunnel is to be modified to operate with sulfur hexafluoride gas while retaining its present capability to operate with nitrogen. The modified tunnel will provide high Reynolds number flow on aerodynamic models with two different test gases. The document details a study of the SF6 tunnel performance boundaries, thermodynamic modeling of the tunnel process, nonlinear dynamical simulation of math model to yield tunnel responses, the closed loop control requirements, control laws, and mechanization of the control laws on the microprocessor based controller.

Balakrishna, S.↗

Control of large cryogenic tunnels

For the efficient and economic operation of large cryogenic wind tunnels, automatic control is necessary to precisely regulate the temperature, pressure, and Mach number. The features of the control system currently in operation at the U.S. National Transonic Facility are presented. Some unique features of the tunnel temperature control law are the automatic tunnel cool down utilizing structural temperature feedback and the fan power based liquid nitrogen nozzle switching logic that have played a key role in realizing good automatic tunnel control.

Balakrishna, S.↗

The NASA Langley Research Center 0.3-meter transonic cryogenic tunnel microcomputer controller source code

The 0.3 m Transonic Cryogenic Tunnel (TCT) microcomputer based controller has been operating for several thousand hours in a safe and efficient manner. A complete listing is provided of the source codes for the tunnel controller and tunnel simulator. Included also is a listing of all the variables used in these programs. Several changes made to the controller are described. These changes are to improve the controller ease of use and safety.

Kilgore, W. Allen↗

Automatic control of cryogenic wind tunnels

Inadequate Reynolds number similarity in testing of scaled models affects the quality of aerodynamic data from wind tunnels. This is due to scale effects of boundary-layer shock wave interaction which is likely to be severe at transonic speeds. The idea of operation of wind tunnels using test gas cooled to cryogenic temperatures has yielded a quantrum jump in the ability to realize full scale Reynolds number flow similarity in small transonic tunnels. In such tunnels, the basic flow control problem consists of obtaining and maintaining the desired test section flow parameters. Mach number, Reynolds number, and dynamic pressure are the three flow parameters that are usually required to be kept constant during the period of model aerodynamic data acquisition. The series of activity involved in modeling, control law development, mechanization of the control laws on a microcomputer, and the performance of a globally stable automatic control system for the 0.3-m Transonic Cryogenic Tunnel (TCT) are discussed. A lumped multi-variable nonlinear dynamic model of the cryogenic tunnel, generation of a set of linear control laws for small perturbation, and nonlinear control strategy for large set point changes including tunnel trajectory control are described. The details of mechanization of the control laws on a 16 bit microcomputer system, the software features, operator interface, the display and safety are discussed. The controller is shown to provide globally stable and reliable temperature control to + or - 0.2 K, pressure to + or - 0.07 psi and Mach number to + or - 0.002 of the set point value. This performance is obtained both during large set point commands as for a tunnel cooldown, and during aerodynamic data acquisition with intrusive activity like geometrical changes in the test section such as angle of attack changes, drag rake movements, wall adaptation and sidewall boundary-layer removal. Feasibility of the use of an automatic Reynolds number control mode with fixed Mach number control is demonstrated.

Balakrishna, S.↗