Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer

Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the European Space Agency (ESA) ExoMars 2020 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). MOMA-MS is a life-detection instrument and thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 spore/m2 are allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three clean rooms with varying levels of bioburden control. The Aseptic Assembly Clean room has the highest level of control, applying three different bioburden reducing methods: 70% Isopropyl Alcohol (IPA), 7.5% Hydrogen Peroxide, and Ultra-Violet C (UVC) light. The three methods are used in rotation and each kills microorganisms by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Clean rooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of clean rooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and Dry Heat microbial Reduction (DHMR) verification. The clean rooms are monitored for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic and other clean room.

Contamination Control Engineering↗

Alternate Protocol for Detecting Biological Contamination on Sensitive Hardware

The purpose of this project is to develop a sterile water based rapid bioburden test. Contamination engineers use two tests to assess the level of biological contamination on hardware: the rapid five minute bioburden test, which is a molecular screening for Adenosine triphosphate (ATP), a molecule found in all cells on the hardware, and a slower colony growth test, which is used to give a more accurate representation of the amount of microbes on the hardware. However, the rapid bioburden test has limited application because it leaves a residue that can be detrimental to sensitive hardware. This can cause project delays while waiting for the results from the three day colony growth test. We address this problem by adapting the commercial germicide based ATP system to a sterile water based system. The test works by reacting ATP with D-Luciferin and Luciferase protein to yield light. The light is then detected by a luminometer that outputs a Relative Light Unit (RLU) amount depending on how much ATP is present. To analyze the effectiveness of the new test, we developed a correlation between amounts of ATP and the RLU produced using the germicide based system. From these experiments, we've generated a consistent relationship between the two in the form of a power curve. From there, we developed a correlation curve between the amount of colonies and the RLU they produced. Initial tests of the new protocol have shown that the water based system isn't as sensitive as the germicide based test.

planetary protection↗