System considerations for an earth radiation budget scanning radiometer
Error sources that might affect the earth radiation budget (ERBSI) scanner radiometer are discussed. Effects of sensor time response, spatial averaging by the field of view, onboard processing, and level III averaging are examined, coverage of grid regions is considered, and an analysis procedure for a scanning radiometer is derived. ERBSI consists of a scanning radiometer, sensors, and a solar radiometer, and it is suggested that ERBSI be included in the instrument complement of NOAA operational spacecraft.