Scheimpflug LIDAR for Gas Sensing at Elevated Temperatures

Localized operating conditions inside boilers, heat recovery steam generators, or other large thermal systems have a huge impact on the efficiency, environmental performance, and lifetime of components. It is extremely difficult to measure species accurately within these systems due to the high temperatures and harsh environments, locally oxidizing or reducing atmospheres, ash, other particulates, and other damaging chemical species. Physical probes quickly suffer damage and are rendered nonfunctional. This work has attempted to adapt the measurement approach based on Scheimpflug light detection and ranging (S-LIDAR) for the remote sensing of gas species inside the high-temperature boiler environment. For a proof-of-concept, the detection of Raman signals of N 2 , O 2 , and CO 2 and their behavior with increasing temperature have been presented.

47 OTHER INSTRUMENTATION↗

Advanced Sensors for In-Situ Amine Degradation Monitoring in Post-Combustion Carbon Capture

In order to improve the long-term performance of post-combustion carbon capture technologies, improvements to the detection of solvent degradation or reduction in CO2 capture efficiency are necessary. A pair of sensors were deployed to the National Carbon Capture Center’s (NCCC) to monitor CO2 capture and solvent degradation. The CO2 sensors were located to measure before capture and after capture concentrations of CO2 to measure the capture efficiency of the solvent system. Amine degradation sensors were located at four locations along the main solvent lines corresponding to CO2 loading and temperature: hot rich, cold rich, hot lean, and cold lean. Experimental results from laboratory tests using the sensors are shown, along with prototype designs that were deployed to the field site.

Brister, Matthew↗

Rare Earth Elements (REEs) Measurement in Coal and Rock Mineral Matrices

Although critical minerals including rare earth elements (REEs) can be analyzed in laboratory by some established and reliable laboratory based analytical techniques, their in-situ measurements in the field have always been challenging. For identification of REE-rich sites and REEs distribution measurement, portable field applicable technologies are paramount. As Laser-induced breakdown spectroscopy (LIBS) has enormous potential for field measurement, it has been explored for REEs measurements by many research groups. However, most of the studies are still dealing with simulated samples with traditional bench top experiments. In real world, REEs are available in various types of natural complex matrices in low content depending on the geographical locations. Considering this, LIBS has been evaluated for REE measurement in two different complex coal and rock mineral matrices representing some natural REE-rich sites. In addition, multiple samples collected from some natural sites in Wyoming, USA were experimented by using NETL’s bench top as well as miniaturized prototype setups for REE measurements.

Bhatt, Chet R.↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

Evaluation of analytical performance of double pulse laser-induced breakdown spectroscopy for the detection of rare earth elements

Double pulse laser-induced breakdown spectroscopy (DP-LIBS) in collinear configuration was demonstrated to enhance the signal intensity of three rare earth elements (REEs), Eu, Gd, Pr, and Y (Yttrium is included because of its similar chemical properties and occurrence in similar deposits as REE). Significant enhancement in spectral signals of all elements was observed with an aid of second laser. Two laser pulses of 1064 nm wavelength were employed in collinear geometry on the Pr 2 O 3 , Eu 2 O 3 , Gd 2 O 3 , and Y 2 O 3 pellets to obtain emission spectra. For selected strong emission lines of Eu and Gd signal enhancement was found to be 3 to 7-fold and that for Y and Pr lines was observed to be 3 to 13-fold compared to single-pulse laser-induced breakdown spectroscopy (SP-LIBS). Role of inter-pulse delay between two pulses in DP-LIBS was found to be very crucial. Furthermore, while comparing selected ionic and neutral lines, ionic lines were found to have larger signal enhancement in DP-LIBS at the experimental conditions used in this study.

47 OTHER INSTRUMENTATION↗

Mineral carbonate dissolution with increasing CO 2 pressure measured by underwater laser induced breakdown spectroscopy and its application in carbon sequestration

In this study, the ability of laser-induced breakdown spectroscopy (LIBS) to measure the in situ aqueous dissolution of various mineral carbonates with increasing CO 2 pressure was examined. Dissolution experiments included four geologically common mineral carbonates (CaCO 3 , MgCO 3 , MnCO 3 , SrCO 3 ) and the CO 2 pressure ranged from ambient to 250 bar. The ensuing plasma emission was spectrally analyzed, and the intensities of Ca, Mg, Mn, and Sr emission lines were used to monitor the respective metal cations released to the aqueous solution. The strong emission lines of Ca (Ca II 393.36, Ca II 396.84, Ca I 422.67 nm), Mg (unresolved magnesium doublet: Mg I 383.230, Mg I 383.829 nm), Mn (unresolved manganese triplet: Mn I 403.076, Mn I 403.307, Mn I 403.449 nm), and Sr (Sr II 407.77, Sr II 421.55, Sr I 460.73 nm) were identified in the spectra. The amounts of metals released from their respective carbonates were estimated at different time intervals following the CO 2 injection (5 m, 1, 2, 3, 4, 24 h) and at different pressures (50, 100, 150, 200, 250 bar) using calibration models developed at corresponding pressure settings. The results demonstrated that the pressure-induced dissolution of all carbonates was consistent with their expected and selective pH-dependent solubility. The dissolution rate of CaCO 3 , MgCO 3 , and SrCO 3 was found to be higher than that of MnCO 3 . The dissolution of constituents in a Mt. Simon sandstone associated with a deep saline reservoir at elevated CO 2 pressure was also studied and Ca release was quantified. The results demonstrated that real-time monitoring of carbonate dissolution by LIBS may provide a useful indirect detection system indicative of CO 2 leakage from geologic carbon storage sites.

58 GEOSCIENCES↗