Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Polarization performance simulation for the GeoXO atmospheric composition instrument: NO2 retrieval impacts

NOAA’s Geostationary Extended Observations (GeoXO) constellation will continue and expand on the capabilities of the current generation of geostationary satellite systems to support US weather, ocean, atmosphere, and climate operations. It is planned to consist of a dedicated atmospheric composition instrument (ACX) to support air quality forecasting and monitoring by providing similar capabilities to missions such as TEMPO (Tropospheric Emission: Monitoring Pollution), currently planned to launch in 2023, and Ozone Monitoring Instrument (OMI), TROPOMI (TROPOspheric Monitoring Instrument), and GEMS (Geostationary Environment Monitoring Spectrometer) currently in operation. As the early phases of ACX development are progressing, design trade-offs are being considered to understand the relationship between instrument design choices and trace gas retrieval impacts. Some of these choices will affect the instrument polarization sensitivity (PS), which can have radiometric impacts on environmental satellite observations. We conducted a study to investigate how such radiometric impacts can affect NO2 retrievals by exploring their sensitivities to time of day, location, and scene type with an ACX instrument model that incorporates PS. The study addresses the basic steps of operational NO2 retrievals: the spectral fitting step and the conversion of slant column to vertical column via the air mass factor (AMF). The spectral fitting step was performed by generating at-sensor radiance from a clear sky scene with a known NO2 amount, the application of an instrument model including both instrument PS and noise, and a physical retrieval. The spectral fitting step was found to mitigate the impacts of instrument PS. The AMF-related step was considered for clear sky and partially cloudy scenes, where instrument PS can lead to errors in interpreting the cloud content, propagating to AMF errors and finally to NO2 retrieval errors. For this step, the NO2 retrieval impacts were small but non-negligible for high NO2 amounts; we estimated that a typical high NO2 amount can cause maximum of 0.25 x 10^15 molecules/cm^2 for a PS of 5%. These simulation capabilities were designed to aid in the development of a GeoXO atmospheric composition instrument that will improve our ability to monitor and understand the Earth’s atmosphere.

trace gases↗

Polarization Performance Simulation for the GeoXO Atmospheric Composition Instrument: NO2 Retrieval Impacts

NOAA's Geostationary Extended Observations (GeoXO) constellation will continue and expand on the capabilities of the current generation of geostationary satellite systems to support US weather, ocean, atmosphere, and climate operations. It is planned to consist of a dedicated atmospheric composition instrument (ACX) to support air quality forecasting and monitoring by providing capabilities similar to missions such as TEMPO (Tropospheric Emission: Monitoring Pollution), currently planned to launch in 2023, as well as OMI (Ozone Monitoring Instrument), TROPOMI (TROPOspheric Monitoring Instrument), and GEMS (Geostationary Environment Monitoring Spectrometer) currently in operation. As the early phases of ACX development are progressing, design trade-offs are being considered to understand the relationship between instrument design choices and trace gas retrieval impacts. Some of these choices will affect the instrument polarization sensitivity (PS), which can have radiometric impacts on environmental satellite observations. We conducted a study to investigate how such radiometric impacts can affect NO2 retrievals by exploring their sensitivities to time of day, location, and scene type with an ACX instrument model that incorporates PS. The study addresses the basic steps of operational NO2 retrievals: the spectral fitting step and the conversion of slant column to vertical column via the air mass factor (AMF). The spectral fitting step was performed by generating at-sensor radiance from a clear-sky scene with a known NO2 amount, the application of an instrument model including both instrument PS and noise, and a physical retrieval. The spectral fitting step was found to mitigate the impacts of instrument PS. The AMF-related step was considered for clear-sky and partially cloudy scenes, for which instrument PS can lead to errors in interpreting the cloud content, propagating to AMF errors and finally to NO2 retrieval errors. For this step, the NO2 retrieval impacts were small but non-negligible for high NO2 amounts; we estimated that a typical high NO2 amount can cause a maximum retrieval error of 0.25×1015 molec. cm−2 for a PS of 5 %. These simulation capabilities were designed to aid in the development of a GeoXO atmospheric composition instrument that will improve our ability to monitor and understand the Earth's atmosphere.

Aaron Pearlman↗

Pre-launch Radiometric Calibration and Uncertainty Analysis of Landsat Thermal Infrared Sensor 2

The Thermal Infrared Sensor-2 that will be on-board Landsat 9 has undergone a pre-launch testing campaign to characterize its radiometric, spectral, and spatial performance and demonstrate compliance to its requirements. This work reviews key elements of the instrument-level radiometric testing using an SI traceable source to derive its uncertainties. Those arising from on-orbit calibration using the TIRS-2 on-board blackbody are also discussed. We use a Monte Carlo approach to propagate the uncertainties through a non-linear calibration equation and address both random and systematic uncertainty terms. Achieving the required performance demonstrates the instrument’s potential for enhancing our understanding of the Earth’s environment.

Landsat↗

Prelaunch Radiometric Calibration and Uncertainty Analysis of Landsat Thermal Infrared Sensor 2

The Thermal Infrared Sensor-2 (TIRS-2) that will be onboard Landsat 9 has undergone a prelaunch testing campaign to characterize its radiometric, spectral, and spatial performances and demonstrate compliance to its requirements. This work reviews the key elements of the instrument-level radiometric testing using an SI-traceable source to derive its uncertainties. Those arising from on-orbit calibration using the TIRS-2 onboard blackbody are also discussed. We use a Monte Carlo approach to propagate the uncertainties through a nonlinear calibration equation and address both random and systematic uncertainty terms. Achieving the required performance demonstrates the instrument's potential for enhancing our understanding of the Earth's environment.

Aaron Pearlman↗

GOES-16 ABI Solar Reflective Channel Validation for Earth Science Application

This paper presents the validation results of GOES-16 Satellite's Advanced Baseline Imager (ABI) obtained from a reflectance-based field campaign undertaken at the Salar de Uyuni in Bolivia in June 2017. In situ ground measurements are used to characterize the surface reflectance and the atmosphere in order to constrain the radiative transfer code and predict at-sensor reflectance (also referred to as top-of-atmosphere (TOA) reflectance) to compare with concurrent GOES-16 ABI measurements. The five-day field campaign provided repeated TOA reflectance estimates, allowing assessment not only of the calibration accuracy of the ABI reflective channels 1, 2, 3, 5 and 6, but also of its stability over the duration of the campaign. The results show that the accuracy of the ABI reflective channels calibration is within specification for channels 1, 3, 5, and 6 - average biases within 2%; for channel 2 the bias is 5%. The estimated uncertainty on the derived biases is 2–2.4%. Some calibration stability issues were present in the ABI calibration at the time of the campaign: (i) a jump on the order of 2% in channels 1 and 6, coincident with an ABI solar calibration event, reflects an instability of the ABI gains in these channels, and (ii) short-term variability in channels 1 and 2 is due to striping (ABI detector-todetector calibration differences). Continued validation and subsequent reprocessing of ABI reflectance imagery would allow Earth scientists to fully benefit from the high spatial and spectral fidelity of the GOES-16 ABI diurnal measurements at the continental scale.

Joel McCorkel↗

LANDSAT 9: Mission Status and Prelaunch Instrument Performance Characterization and Calibration

Landsat 9 is currently under development as a joint effort between NASA and the United States Geological Survey (USGS). Landsat 9 is largely a rebuild of Landsat 8 and has the same two sensors, an Operational Land Imager (OLI) and a Thermal InfraRed Sensor(TIRS). The OLI-2 on Landsat 9, being built by Ball Aerospace, has completed its pre-launch characterization and calibration and is scheduled to be delivered in the summer of 2019. The TIRS-2, with improved stray light performance and increased redundancy for improved reliability, is being built by Goddard Space Flight Center. TIRS-2is undergoing testing through Spring 2019 and is also scheduled for summer2019 delivery. Several improvements to the characterization of both instruments have been incorporated into the testing plan, including improved spectral and radiometric characterization. The instruments will then be integrated onto the spacecraft being built by Northrop Grumman Innovation Systems (NGIS). The mission is targeted to launch as early as December 2020 on an Atlas V.

Landsat↗

Validation of GOES-17 ABI Reflective Channels Performance: Salar De Uyuni 2018 Field Campaign Results

Validation results from a reflectance-based field campaign at the Salar de Uyuni in Bolivia (September 2018) are presented for GOES-17 and GOES-16 Advanced Baseline Imagers (ABI) reflective channels. The in situ measurements were used to characterize the surface reflectance and the atmosphere in order to constrain a radiative transfer model and predict the reflectance at the top of the atmosphere (TOA), which was then compared to the ABI measurements. The field campaign provides TOA reflectance estimates over several days, allowing assessment of the calibration accuracy and stability of channels 1, 2, 3, 5 and 6 for GOES-17 andGOES-16 ABI. Channel 1 of GOES-17 ABI shows -5.5% bias in comparison to the ground-based predicted TOA. Over 6% bias in GOES-17 B2 was confirmed. A comparison to NOAA-20 VIIRS was also carried on during a near nadir overpass.

validation↗

A Modeling and Simulation Study for the GeoXO Atmospheric Composition Instrument (ACX): System Level SO2 and O3 Retrieval Performance as a Function of SNR

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral UV/visible atmospheric composition instrument in geostationary orbit slated for operations by the early 2030s. Trace gas retrievals provide critical information about our Earth’s system as it relates to both natural and anthropogenic activity. This work focused on the impacts of the signal-to-noise ratio (SNR) on the retrieval uncertainty of SO2 and O3. An end-to-end physics-based imaging system and scene modeling and simulation framework was developed to assess instrument performance considerations in support of the planned GeoXO atmospheric composition instrument (ACX). The framework is composed of three primary components: 1) simulated at-sensor radiance via radiative transfer models of a known atmospheric composition, 2) a noise model driven by previous and planned sensor specifications, and 3) a physical retrieval algorithm. In this analysis, the tropospheric concentrations of SO2 and O3 in the atmospheric column were varied in the boundary layer (0-3 km) and at an elevation of 5 km with a thickness of 1-2 km; the uncertainty in retrieval was studied for various SNR levels for multiple viewing geometries and solar zenith angles. This effort supports the development of the GeoXO ACX instrument by providing a simulated ACX performance assessment of the system-level retrieval performance as a function of SNR, particularly with respect to the wavelength range of interest (approximately 305 – 340 nm) for SO2 and O3 trace gas retrievals.

Monica Cook↗

GeoXO Ocean Color Instrument (OCX) Spatial and Temporal Coverage Assessment

NOAA’s next generation Geostationary Extended Observations (GeoXO) satellite system will advance Earth observations from geostationary orbit. GeoXO will supply vital information supporting the U.S. weather, ocean, and climate operations. The recommended three-satellite constellation includes spacecrafts at the current GOES-East and GOES-West positions that will carry an imager, lightning mapper, and an ocean color (OCX) instrument. In this poster we describe an assessment of U.S. Exclusive Economic Zone (EEZ) availability for OCX observations, based on EEZ view geometry, solar angle range over the year, sun glint, as well as cloud climatology. The availability for observations for each EEZ region is estimated per day of the year, as function of atmospheric mass factor (AMF) and sun glint. In addition, cloud climatology – based on statistics derived from three years of GOES-16 ABI cloud mask – is considered to determine the fraction of cloud-free OCX observations for each region as function of time of day and season. The results of such assessments can be used to optimize OCX collections and potentially explore regions outside the EEZ.

Boryana Efremova↗

An Initial Assessment of the Impact of System Spectral Response Parameters on Driving Ocean Color Applications for the GeoXO Ocean Color Instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A dataset of high resolution (1 nm spectral sampling) in-situ spectra of red tide collected with an above water spectrometer, and associated K. brevis cell concentrations, were used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX. Future work will seek to expand this analysis to include a larger dataset that considers additional water cases.

Monica Cook↗

An assessment of the impact of system spectral response parameters on spectral shape and algal bloom detection for the GeoXO ocean color instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A large dataset in-situ spectra, from a variety of locations and water cases collected with an above water spectrometer, was used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX.

Monica Cook↗

GeoXO Atmospheric Composition Instrument (AC) Measurements Conditions Assessment

NOAA’s next generation Geostationary Extended Observations (GeoXO) satellite system will advance Earth observations from geostationary orbit. GeoXO will supply vital information supporting the U.S. weather, ocean, and climate operations. The recommended three-satellite constellation includes spacecraft at GOES-Central position, that will carry an Atmospheric Composition Instrument (ACX) among its payloads; the requirement on the ACX is to scan its region of interest in one hour. An assessment of ACX observational conditions is presented, based on view geometry and solar angle range over the year. The availability for observations of each pixel is estimated per day of the year, as function of the geometric air mass factor (AMF), which can be related to signal to noise ratio using a model of the ACX instrument performance, and ultimately to expected column error for specific atmospheric species. In addition, cloud climatology – based on statistics derived from GOES-16 ABI cloud product data – is considered to determine typical fractions of cloud-free ACX observations and typical cloud optical depths, for each pixel as function of time of day and season. The results of such assessments can be used to prepare for GeoXO ACX data and further the understanding and development of the future instrument operations.

Boryana Efremova↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.