Search NASA⌕ Search

Engineering topics

Bouet, Nathalie (ORCID:0000000258169429)

Publications and source records attributed to Bouet, Nathalie (ORCID:0000000258169429).

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

Micromachined Silicon Platform for Precise Assembly of 2D Multilayer Laue Lenses for High-Resolution X-ray Microscopy

We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.

36 MATERIALS SCIENCE↗