Technical challenges of sparing infrahyoid swallowing organs at risk in oropharynx squamous cell cancer treated with IMRT

This study reports clinical performance in the sparing of infrahyoid swallowing organs at risk (SWOARs) in oropharynx cancer intensity-modulated radiation therapy (IMRT) plans. Rates of meeting dose-volume planning goals are reported and compared with geometry-based estimates of what is achievable. This study also develops 3 measures of target-SWOAR geometry and tests their usefulness in providing geometry-based dose-volume planning goals. A total of 50 oropharynx cancer IMRT plans were reviewed. Success rates in meeting institutional dose-volume goals were determined for the glottic larynx (G), postcricoid pharynx (P), and esophagus (E). The following 3 measures of target-SWOAR geometry were investigated as methods of identifying geometry-based planning goals: presence of gross disease in neck levels 3 to 4, target-SWOAR overlap, and a 3-dimensional (3D) measure of target-SWOAR geometry. Locally advanced disease was predominant in this patient population with target volumes overlapping SWOARs in 68% to 98% of cases. Clinical rates of success in meeting dose-volume goals varied by SWOAR (16% to 82%) but compared well with estimated potentially achievable rates in most cases (14% average difference between clinical and potential). Cases grouped by the presence of levels 3 to 4 neck nodes or target-SWOAR overlap did not have significantly different SWOAR doses. Cases grouped using a 3D measure of target-SWOAR geometry differed significantly, providing useful geometry-based planning goals (e.g., mean Glottis dose <45 Gy was achieved 19%, 44%, or 81% of the time in each of 3 groups). This study describes the technical challenge of sparing SWOARs and investigates several potential methods for grouping cases to assist with treatment plan evaluation. Quantifying the 3-D relationship between the targets and SWOARs is a promising way of approaching this complex problem. Data presented in this paper may be useful to evaluate treatment plans using objective geometry-based goals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Auto-segmentation of normal and target structures in head and neck CT images: A feature-driven model-based approach

Purpose: Intensity modulated radiation therapy (IMRT) allows greater control over dose distribution, which leads to a decrease in radiation related toxicity. IMRT, however, requires precise and accurate delineation of the organs at risk and target volumes. Manual delineation is tedious and suffers from both interobserver and intraobserver variability. State of the art auto-segmentation methods are either atlas-based, model-based or hybrid however, robust fully automated segmentation is often difficult due to the insufficient discriminative information provided by standard medical imaging modalities for certain tissue types. In this paper, the authors present a fully automated hybrid approach which combines deformable registration with the model-based approach to accurately segment normal and target tissues from head and neck CT images. Methods: The segmentation process starts by using an average atlas to reliably identify salient landmarks in the patient image. The relationship between these landmarks and the reference dataset serves to guide a deformable registration algorithm, which allows for a close initialization of a set of organ-specific deformable models in the patient image, ensuring their robust adaptation to the boundaries of the structures. Finally, the models are automatically fine adjusted by our boundary refinement approach which attempts to model the uncertainty in model adaptation using a probabilistic mask. This uncertainty is subsequently resolved by voxel classification based on local low-level organ-specific features. Results: To quantitatively evaluate the method, they auto-segment several organs at risk and target tissues from 10 head and neck CT images. They compare the segmentations to the manual delineations outlined by the expert. The evaluation is carried out by estimating two common quantitative measures on 10 datasets: volume overlap fraction or the Dice similarity coefficient (DSC), and a geometrical metric, the median symmetric Hausdorff distance (HD), which is evaluated slice-wise. They achieve an average overlap of 93% for the mandible, 91% for the brainstem, 83% for the parotids, 83% for the submandibular glands, and 74% for the lymph node levels. Conclusions: Our automated segmentation framework is able to segment anatomy in the head and neck region with high accuracy within a clinically-acceptable segmentation time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical process control for IMRT dosimetric verification

Patient-specific measurements are typically used to validate the dosimetry of intensity-modulated radiotherapy (IMRT). To evaluate the dosimetric performance over time of our IMRT process, we have used statistical process control (SPC) concepts to analyze the measurements from 330 head and neck (H and N) treatment plans. The objectives of the present work are to: (i) Review the dosimetric measurements of a large series of consecutive head and neck treatment plans to better understand appropriate dosimetric tolerances; (ii) analyze the results with SPC to develop action levels for measured discrepancies; (iii) develop estimates for the number of measurements that are required to describe IMRT dosimetry in the clinical setting; and (iv) evaluate with SPC a new beam model in our planning system. H and N IMRT cases were planned with the PINNACLE{sup 3} treatment planning system versions 6.2b or 7.6c (Philips Medical Systems, Madison, WI) and treated on Varian (Palo Alto, CA) or Elekta (Crawley, UK) linacs. As part of regular quality assurance, plans were recalculated on a 20-cm-diam cylindrical phantom, and ion chamber measurements were made in high-dose volumes (the PTV with highest dose) and in low-dose volumes (spinal cord organ-at-risk, OR). Differences between the planned and measured doses were recorded as a percentage of the planned dose. Differences were stable over time. Measurements with PINNACLE{sup 3} 6.2b and Varian linacs showed a mean difference of 0.6% for PTVs (n=149, range, -4.3% to 6.6%), while OR measurements showed a larger systematic discrepancy (mean 4.5%, range -4.5% to 16.3%) that was due to well-known limitations of the MLC model in the earlier version of the planning system. Measurements with PINNACLE{sup 3} 7.6c and Varian linacs demonstrated a mean difference of 0.2% for PTVs (n=160, range, -3.0%, to 5.0%) and -1.0% for ORs (range -5.8% to 4.4%). The capability index (ratio of specification range to range of the data) was 1.3 for the PTV data, indicating that almost all measurements were within {+-}5%. We have used SPC tools to evaluate a new beam model in our planning system to produce a systematic difference of -0.6% for PTVs and 0.4% for ORs, although the number of measurements is smaller (n=25). Analysis of this large series of H and N IMRT measurements demonstrated that our IMRT dosimetry was stable over time and within accepted tolerances. These data provide useful information for assessing alterations to beam models in the planning system. IMRT is enhanced by the addition of statistical process control to traditional quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗