Search NASA⌕ Search

Engineering topics

Chang, D. S.

Publications and source records attributed to Chang, D. S..

Cutaneous microvascular flow in the foot during simulated variable gravities

Our objective was to understand how weight bearing with varying gravitational fields affects blood perfusion in the sole of the foot. Human subjects underwent whole body tilting at four angles: upright [1 gravitational vector from head to foot (Gz)], 22 degrees (0.38 Gz), 10 degrees (0.17 Gz), and supine (0 Gz), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight-bearing load was measured. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of 1 kg beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load. Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load). Mean closing loads for simulated Earth gravity, Mars gravity, Moon gravity, and microgravity were 9.1, 4.6, 4.4, and 3.6 kg, respectively. Mean opening loads were 7.9, 4.1, 3.5, and 3.1 kg, respectively. Mean arterial pressures in the foot (MAP(foot)) calculated for each simulated gravitational field were 192, 127, 106, and 87 mmHg, respectively. Closing load and opening load were significantly correlated with MAP(foot) (r =0.70, 0.72, respectively) and were significantly different (P < 0.001) from each other. The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischemia during load bearing in microgravity than on Earth.

NASA Discipline Cardiopulmonary↗

Ultrasound measurement of transcranial distance during head-down tilt

Exposure to microgravity elevates blood pressure and flow in the head, which may increase intracranial volume (ICV) and intracranial pressure (ICP). Rhesus monkeys exposed to simulated microgravity in the form of 6 degree head-down tilt (HDT) experience elevated ICP. With humans, twenty-four hours of 6 degree HDT bed rest increases cerebral blood flow velocity relative to pre-HDT upright posture. Humans exposed to acute 6 degree HDT experiments increased ICP, measured with the tympanic membrane displacement (TMD) technique. Other studies suggest that increased ICP in humans and cats causes measurable cranial bone movement across the sagittal suture. Due to the slightly compliant nature of the cranium, elevation of the ICP will increase ICV and transcranial distance. Currently, several non-invasive approaches to monitor ICP are being investigated. Such techniques include TMD and modal analysis of the skull. TMD may not be reliable over a large range of ICP and neither method is capable of measuring the small changes in pressure. Ultrasound, however, may reliably measure small distance changes that accompany ICP fluctuations. The purpose of our study was to develop and evaluate an ultrasound technique to measure transcranial distance changes during HDT.

Torikoshi, S.↗