Cutaneous microvascular flow in the foot during simulated variable gravities

Abstract

Our objective was to understand how weight bearing with varying gravitational fields affects blood perfusion in the sole of the foot. Human subjects underwent whole body tilting at four angles: upright [1 gravitational vector from head to foot (Gz)], 22 degrees (0.38 Gz), 10 degrees (0.17 Gz), and supine (0 Gz), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight-bearing load was measured. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of 1 kg beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load. Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load). Mean closing loads for simulated Earth gravity, Mars gravity, Moon gravity, and microgravity were 9.1, 4.6, 4.4, and 3.6 kg, respectively. Mean opening loads were 7.9, 4.1, 3.5, and 3.1 kg, respectively. Mean arterial pressures in the foot (MAP(foot)) calculated for each simulated gravitational field were 192, 127, 106, and 87 mmHg, respectively. Closing load and opening load were significantly correlated with MAP(foot) (r =0.70, 0.72, respectively) and were significantly different (P < 0.001) from each other. The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischemia during load bearing in microgravity than on Earth.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chang, D. S., Breit, G. A., Styf, J. R., Hargens, A. R.. 1996-10-01. Cutaneous microvascular flow in the foot during simulated variable gravities. https://ntrs.nasa.gov/citations/20040173129

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Effect of stromal-cell-derived factor 1 on stem-cell homing and tissue regeneration in ischaemic cardiomyopathy

BACKGROUND: Myocardial regeneration via stem-cell mobilisation at the time of myocardial infarction is known to occur, although the mechanism for stem-cell homing to infarcted tissue subsequently and whether this approach can be used for treatment of ischaemic cardiomyopathy are unknown. We investigated these issues in a Lewis rat model (ligation of the left anterior descending artery) of ischaemic cardiomyopathy. METHODS: We studied the effects of stem-cell mobilisation by use of granulocyte colony-stimulating factor (filgrastim) with or without transplantation of syngeneic cells. Shortening fraction and myocardial strain by tissue doppler imaging were quantified by echocardiography. FINDINGS: Stem-cell mobilisation with filgrastim alone did not lead to engraftment of bone-marrow-derived cells. Stromal-cell-derived factor 1 (SDF-1), required for stem-cell homing to bone marrow, was upregulated immediately after myocardial infarction and downregulated within 7 days. 8 weeks after myocardial infarction, transplantation into the peri-infarct zone of syngeneic cardiac fibroblasts stably transfected to express SDF-1 induced homing of CD117-positive stem cells to injured myocardium after filgrastim administration (control vs SDF-1-expressing cardiac fibroblasts mean 7.2 [SD 3.4] vs 33.2 [6.0] cells/mm2, n=4 per group, p<0.02) resulting in greater left-ventricular mass (1.24 [0.29] vs 1.57 [0.27] g) and better cardiac function (shortening fraction 9.2 [4.9] vs 17.2 [4.2]%, n=8 per group, p<0.05). INTERPRETATION: These findings show that SDF-1 is sufficient to induce therapeutic stem-cell homing to injured myocardium and suggest a strategy for directed stem-cell engraftment into injured tissues. Our findings also indicate that therapeutic strategies focused on stem-cell mobilisation for regeneration of myocardial tissue must be initiated within days of myocardial infarction unless signalling for stem-cell homing is re-established.

NASA Discipline Cardiopulmonary↗

Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures

INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.

NASA Discipline Cardiopulmonary↗

T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation

In a trial of prophylactic implantation of a defibrillator, a mortality benefit was seen among patients with previous myocardial infarction and a left-ventricular ejection fraction of 0.30 or less. We identified 129 similar patients from two previously published clinical trials in which microvolt T-wave alternans testing was prospectively assessed. At 24 months of follow-up, no sudden cardiac death or cardiac arrest was seen among patients who tested T-wave alternans negative, compared with an event rate of 15.6% among the remaining patients. Testing of T-wave alternans seems to identify patients who are at low risk of ventricular tachyarrhythmic event and who may not benefit from defibrillator therapy.