Search NASA⌕ Search

Engineering topics

Chen, W.

Publications and source records attributed to Chen, W..

At least 73 records · Page 4

Accurate reaction-diffusion operator splitting on tetrahedral meshes for parallel stochastic molecular simulations

Spatial stochastic molecular simulations in biology are limited by the intense computation required to track molecules in space either in a discrete time or discrete space framework, which has led to the development of parallel methods that can take advantage of the power of modern supercomputers in recent years. We systematically test suggested components of stochastic reaction-diffusion operator splitting in the literature and discuss their effects on accuracy. We introduce an operator splitting implementation for irregular meshes that enhances accuracy with minimal performance cost. We test a range of models in small-scale MPI simulations from simple diffusion models to realistic biological models and find that multi-dimensional geometry partitioning is an important consideration for optimum performance. We demonstrate performance gains of 1-3 orders of magnitude in the parallel implementation, with peak performance strongly dependent on model specification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the radial neutron camera system for the HL-2A tokamak

A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasma have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard {sup 235}U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlling slow and fast light and dynamic pulse-splitting with tunable optical gain in a whispering-gallery-mode microcavity

We report controllable manipulation of slow and fast light in a whispering-gallery-mode microtoroid resonator fabricated from Erbium (Er{sup 3+}) doped silica. We observe continuous transition of the coupling between the fiber-taper waveguide and the microresonator from undercoupling to critical coupling and then to overcoupling regimes by increasing the pump power even though the spatial distance between the resonator and the waveguide was kept fixed. This, in turn, enables switching from fast to slow light and vice versa just by increasing the optical gain. An enhancement of delay of two-fold over the passive silica resonator (no optical gain) was observed in the slow light regime. Moreover, we show dynamic pulse splitting and its control in slow/fast light systems using optical gain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Upgrade of electron cyclotron emission imaging system and preliminary results on HL-2A tokamak

The electron cyclotron emission imaging system on the HL-2A tokamak has been upgraded to 24 (poloidally) × 16 (radially) channels based on the previous 24 × 8 array. The measurement region can be flexibly shifted due to the independence of the two local oscillator sources, and the field of view can be adjusted easily by changing the position of the zoom lenses. The temporal resolution is about 2.5 μs and the achievable spatial resolution is 1 cm. After laboratory calibration, it was installed on HL-2A tokamak in 2014, and the local 2D mode structures of MHD activities were obtained for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contributed Review: Quantum cascade laser based photoacoustic detection of explosives

Detecting trace explosives and explosive-related compounds has recently become a topic of utmost importance for increasing public security around the world. A wide variety of detection methods and an even wider range of physical chemistry issues are involved in this very challenging area. Optical sensing methods, in particular mid-infrared spectrometry techniques, have a great potential to become a more desirable tools for the detection of explosives. The small size, simplicity, high output power, long-term reliability make external cavity quantum cascade lasers (EC-QCLs) the promising spectroscopic sources for developing analytical instrumentation. This work reviews the current technical progress in EC-QCL-based photoacoustic spectroscopy for explosives detection. The potential for both close-contact and standoff configurations using this technique is completely presented over the course of approximately the last one decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density modulation experiment to determine transport coefficients on Joint-TEXT Tokamak

Density modulation experiments have been conducted on Joint-TEXT (J-TEXT) Tokamak Ohmic discharge to investigate particle transport based on a model with constant diffusion plus inward convection. Like the HCN interferometer, the newly developed three-wave polarimeter-interferometer system (POLARIS) is used to measure the perturbed density. The comparison of results between the HCN interferometer and POLARIS is given. The consistent results indicate the validity of the analysis scheme. At lower densities, the typical particle confinement time τ{sub p} is found to increase with electron density, while it saturates at higher densities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous X-ray diffraction and phase-contrast imaging for investigating material deformation mechanisms during high-rate loading

Using a high-speed camera and an intensified charge-coupled device (ICCD), a simultaneous X-ray imaging and diffraction technique has been developed for studying dynamic material behaviors during high-rate tensile loading. A Kolsky tension bar has been used to pull samples at 1000 s -1 and 5000 s -1 strain-rates for super-elastic equiatomic NiTi and 1100-O series aluminium, respectively. By altering the ICCD gating time, temporal resolutions of 100 ps and 3.37 µs have been achieved in capturing the diffraction patterns of interest, thus equating to single-pulse and 22-pulse X-ray exposure. Furthermore, the sample through-thickness deformation process has been simultaneously imaged via phase-contrast imaging. It is also shown that adequate signal-to-noise ratios are achieved for the detected white-beam diffraction patterns, thereby allowing sufficient information to perform quantitative data analysis diffraction via in-house software ( WBXRD_GUI ). Of current interest is the ability to evaluate crystal d -spacing, texture evolution and material phase transitions, all of which will be established from experiments performed at the aforementioned elevated strain-rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of “pretzelosity” asymmetry of charged pion production in semi-inclusive deep inelastic scattering on a polarized He 3 target

An experiment to measure single-spin asymmetries in semi-inclusive production of charged pions in deep-inelastic scattering on a transversely polarized ³He target was performed at Jefferson Lab in the kinematic region of 0.16 < x < 0.35 and 1.4 < Q² < 2.7 GeV². Our results show that both π ± on 3 He and on neutron pretzelosity asymmetries are consistent with zero within experimental uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transient x-ray diffraction with simultaneous imaging under high strain-rate loading

Real time, in situ, multiframe, diffraction, and imaging measurements on bulk samples under high and ultrahigh strain-rate loading are highly desirable for micro- and mesoscale sciences. We present an experimental demonstration of multiframe transient x-ray diffraction (TXD) along with simultaneous imaging under high strain-rate loading at the Advanced Photon Source beamline 32ID. The feasibility study utilizes high strain-rate Hopkinson bar loading on a Mg alloy. The exposure time in TXD is 2–3 μs, and the frame interval is 26.7–62.5 μs. Various dynamic deformation mechanisms are revealed by TXD, including lattice expansion or compression, crystal plasticity, grain or lattice rotation, and likely grain refinement, as well as considerable anisotropy in deformation. Dynamic strain fields are mapped via x-ray digital image correlation, and are consistent with the diffraction measurements and loading histories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single spin asymmetries in charged kaon production from semi-inclusive deep inelastic scattering on a transversely polarized He 3 target

We report the first measurement of target single spin asymmetries of charged kaons produced in semi-inclusive deep inelastic scattering of electrons off a transversely polarized 3He target. Both the Collins and Sivers moments, which are related to the nucleon transversity and Sivers distributions, respectively, are extracted over the kinematic range of 0.1 < x bj <0.4 for K + and K – production. While the Collins and Sivers moments for K + are consistent with zero within the experimental uncertainties, both moments for K – favor negative values. The Sivers moments are compared to the theoretical prediction from a phenomenological fit to the world data. While the K + Sivers moments are consistent with the prediction, the K – results differ from the prediction at the 2-sigma level.

43 PARTICLE ACCELERATORS↗

Direct electrical observation of plasma wave-related effects in GaN-based two-dimensional electron gases

In this work, signatures of plasma waves in GaN-based high electron mobility transistors were observed by direct electrical measurement at room temperature. Periodic grating-gate device structures were fabricated and characterized by on-wafer G-band (140–220 GHz) s-parameter measurements as a function of gate bias voltage and device geometry. A physics-based equivalent circuit model was used to assist in interpreting the measured s-parameters. The kinetic inductance extracted from the measurement data matches well with theoretical predictions, consistent with direct observation of plasma wave-related effects in GaN-channel devices at room temperature. This observation of electrically significant room-temperature plasma-wave effects in GaN-channel devices may have implications for future millimeter-wave and THz device concepts and designs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The role of beryllium in the band structure of MgZnO: Lifting the valence band maximum

We investigate the effect of Be on the valence band maximum (VBM) of MgZnO by measuring the band offsets of Mg{sub x}Zn{sub 1−x}O/Be{sub x}Mg{sub y}Zn{sub 1−x−y}O heterojunctions using X-ray photoelectron spectroscopy measurements. Mg{sub x}Zn{sub 1−x}O and Be{sub x}Mg{sub y}Zn{sub 1−x−y}O films have been grown on c-plane sapphire substrates by plasma-assisted molecular beam epitaxy. The valence band offset (ΔE{sub V}) of Mg{sub 0.15}Zn{sub 0.85}O (E{sub g} = 3.62 eV)/Be{sub 0.005}Mg{sub 0.19}Zn{sub 0.805}O (E{sub g} = 3.73 eV) heterojunction is 0.01 eV and Be{sub 0.005}Mg{sub 0.19}Zn{sub 0.805}O has a lower VBM. The increased Mg composition is the main factor for the reduction of VBM. The VBM of Mg{sub x}Zn{sub 1−x}O is lower by 0.03 eV with the enlargement of E{sub g} from 3.62 eV to 3.73 eV by increasing Mg composition. Considering the effect of increased Mg composition, it is concluded that the little amount of Be makes the VBM go up by 0.02 eV when the E{sub g} of the alloy is 3.73 eV. The ΔE{sub V} of Mg{sub 0.11}Zn{sub 0.89}O (E{sub g} = 3.56 eV)/Be{sub 0.007}Mg{sub 0.12}Zn{sub 0.873}O (E{sub g} = 3.56 eV) heterojunction is calculated to be 0.03 eV and Be{sub 0.007}Mg{sub 0.12}Zn{sub 0.873}O has a higher VBM than Mg{sub 0.11}Zn{sub 0.89}O, which means that a little amount Be lifts the VBM by 0.03 eV when the E{sub g} of the alloy is 3.56 eV. The experimental measurements have offered a strong support for the theoretical research that alloying Be in Mg{sub x}Zn{sub 1−x}O alloys is hopeful to form a higher VBM and to enhance the p-type dopability of MgZnO.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Very-high energy observations of the galactic center region by VERITAS in 2010-2012

The Galactic center is an interesting region for high-energy (0.1-100 GeV) and very-high-energy (E > 100 GeV) γ-ray observations. Potential sources of GeV/TeV γ-ray emission have been suggested, e.g., the accretion of matter onto the supermassive black hole, cosmic rays from a nearby supernova remnant (e.g., Sgr A East), particle acceleration in a plerion, or the annihilation of dark matter particles. The Galactic center has been detected by EGRET and by Fermi/LAT in the MeV/GeV energy band. At TeV energies, the Galactic center was detected with moderate significance by the CANGAROO and Whipple 10 m telescopes and with high significance by H.E.S.S., MAGIC, and VERITAS. We present the results from three years of VERITAS observations conducted at large zenith angles resulting in a detection of the Galactic center on the level of 18 standard deviations at energies above ∼2.5 TeV. The energy spectrum is derived and is found to be compatible with hadronic, leptonic, and hybrid emission models discussed in the literature. Future, more detailed measurements of the high-energy cutoff and better constraints on the high-energy flux variability will help to refine and/or disentangle the individual models.

79 ASTRONOMY AND ASTROPHYSICS↗