Search NASA⌕ Search

Engineering topics

Chen, W.

Publications and source records attributed to Chen, W..

At least 91 records · Page 5

Note: Dynamic strain field mapping with synchrotron X-ray digital image correlation

We present a dynamic strain field mapping method based on synchrotron X-ray digital image correlation (XDIC). Synchrotron X-ray sources are advantageous for imaging with exceptional spatial and temporal resolutions, and X-ray speckles can be produced either from surface roughness or internal inhomogeneities. Combining speckled X-ray imaging with DIC allows one to map strain fields with high resolutions. Based on experiments on void growth in Al and deformation of a granular material during Kolsky bar/gas gun loading at the Advanced Photon Source beamline 32ID, we demonstrate the feasibility of dynamic XDIC. XDIC is particularly useful for dynamic, in-volume, measurements on opaque materials under high strain-rate, large, deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Target-Normal Single-Spin Asymmetry in Deep-Inelastic Scattering from the Reaction He 3 ↑ ( e , e ' ) X

We report here the first measurement of the target-normal single-spin asymmetry in deep-inelastic scattering from the inclusive reaction He 3 ↑ ( e , e ' ) X on a polarized He 3 gas target. Assuming time-reversal invariance, this asymmetry is strictly zero in the Born approximation but can be nonzero if two-photon-exchange contributions are included. The experiment, conducted at Jefferson Lab using a 5.89 GeV electron beam, covers a range of 1.7 < W < 2.9 GeV , 1.0 < Q 2 < 4.0 GeV 2 and 0.16 < x < 0.65 . Neutron asymmetries were extracted using the effective nucleon polarization and measured proton-to- He 3 cross-section ratios. The measured neutron asymmetries shown are negative with an average value of ( - 1.09 ± 0.38 ) × 1 0 - 2 for invariant mass W > 2 GeV , which is nonzero at the 2.89 σ level. Our measured asymmetry agrees both in sign and magnitude with a two-photon-exchange model prediction that uses input from the Sivers transverse momentum distribution obtained from semi-inclusive deep-inelastic scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single spin asymmetries of inclusive hadrons produced in electron scattering from a transversely polarized 3 He target

We report the first measurement of target single-spin asymmetries (A N ) in the inclusive hadron production reaction, e + 3 He↑→h+X, using a transversely polarized 3 He target. This experiment was conducted at Jefferson Lab in Hall A using a 5.9-GeV electron beam. Three types of hadrons (π ± , K ± and proton) were detected in the transverse hadron momentum range 0.54 < p T < 0.74 GeV/c. The range of x F for pions was -0.29 < x F < -0.23 and for kaons -0.25 < x F <-0.18. The observed asymmetry strongly depends on the type of hadron. A positive asymmetry is observed for π + and K + . A negative asymmetry is observed for π–. The magnitudes of the asymmetries follow |A π – |<|A π + |<|A K + |. The K – and proton asymmetries are consistent with zero within the experimental uncertainties. The π + and π – asymmetries measured for the 3 He target and extracted for neutrons are opposite in sign with a small increase observed as a function of p T .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The role of band alignment in p-type conductivity of Na-doped ZnMgO: Polar versus non-polar

We investigate the electrical properties of polar and non-polar ZnMgO:Na films that have been fabricated on c-plane and r-plane sapphire substrates using intervened ZnO layers (10–30 nm thick) by pulsed laser deposition. Hall-effect measurements indicate that the a-plane ZnMgO:Na film exhibits p-type conductivity with a carrier concentration of about 3.5 × 10{sup 16} cm{sup −3}, while the polar film shows a compensatory conductivity. Meanwhile, the dependence of the band alignment on the orientation of the ZnMgO/ZnO heterojunctions has been investigated using photoelectron spectroscopy. The heterojunctions form in the type-I straddling alignment with valence band offsets of 0.07 (0.02) eV for the (non-)polar heterojunction. The difference in valence band offsets is primarily attributed to the spontaneous polarization effect. We propose that the smaller valence band offsets and larger conduction band offsets would reduce the Na{sub Zn} acceptor level and enhance the relative intrinsic donor levels. Such effects consequently lead to p-type conductivity in non-polar ZnMgO:Na films. The band alignment of non-polar ZnMgO/ZnO can be used to facilitate p-type doping with a shallower acceptor state in the ZnO-like alloy.

36 MATERIALS SCIENCE↗

Crystallinity dependence of resistive switching in Ti/Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7}/Pt: Filamentary versus interfacial mechanisms

The resistive switching characteristics of two Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7} (PSCMO)-based devices (Ti/PSCMO-1/Pt and Ti/PSCMO-2/Pt) prepared under different conditions have been investigated. The two devices both showed bipolar switching behaviors. Scanning electron microscope measurements showed different grain boundaries in the two PSCMO films. By fitting the I-V curves and area dependence of the device resistance, we found that the Ti/PSCMO-1/Pt device indicated filamentary conduction, whereas interfacial effects dominated the conductance in Ti/PSCMO-2/Pt device. Our results suggest that the different grain boundaries may play a critical role in oxygen vacancy movement and hence result in the two different resistive switching properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of a 32 channel electron cyclotron emission radiometer on the HL-2A tokamak

A novel 32-channel electron cyclotron emission radiometer has been designed and tested for the measurement of electron temperature profiles on the HL-2A tokamak. This system is based on the intermediate frequency filter detection technique, and has the features of wide working frequency range and high spatial resolution. Two relative calibration methods have been investigated: sweeping the toroidal magnetic field and hopping the output frequency of the local oscillator. Preliminary results show that both methods can ensure reasonable profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of frequency modulated continuous wave reflectometer for electron density profile measurement on the HL-2A tokamak

The frequency modulated continuous wave reflectometer was developed for the first time on the HL-2A tokamak. The system utilizes a voltage controlled oscillator and an active multiplier for broadband coverage and detects as heterodyne mode. Three reflectometers have been installed and operated in extraordinary mode polarization on HL-2A to measure density profiles at low field side, covering the Q-band (33–50 GHz), V-band (50–75 GHz), and W-band (75–110 GHz). For density profile reconstruction from the phase shift of the probing wave, a corrected phase unwrapping method is introduced in this article. The effectiveness of the method is demonstrated. The density profile behavior of a fast plasma event is presented and it demonstrates the capability of the reflectometer. These diagnostics will be contributed to the routine density profile measurements and the plasma physics study on HL-2A.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of electron cyclotron emission imaging system on the HL-2A tokamak

A 2D electron cyclotron emission imaging (ECEI) system has been developed for measurement of electron temperature fluctuations in the HL-2A tokamak. It is comprised of a front-end 24 channel heterodyne imaging array with a tunable RF range spanning 75–110 GHz, and a set of back-end ECEI electronics that together generate 24 × 8 = 192 channel images of the 2nd harmonic X-mode electron cyclotron emission from the HL-2A plasma. The simulated performance of the local oscillator (LO) optics and radio frequency (RF) optics is presented, together with the laboratory characterization results. The Gaussian beams from the LO optics are observed to properly cover the entire detector array. The ECE signals from the plasma are mixed with the LO signal in the array box, then delivered to the electronics system by low-loss microwave cables, and finally to the digitizers. The ECEI system can achieve temporal resolutions of ∼μs, and spatial resolutions of 1 cm (radially) and 2 cm (poloidally)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed synchrotron x-ray phase contrast imaging of dynamic material response to split Hopkinson bar loading

The successful process of amalgamating both the time-resolved imaging capabilities present at the Advanced Photon Source beamline 32ID-B and the proficiency of high-rate loading offered by the split Hopkinson or Kolsky compression/tension bar apparatus is discussed and verification of system effectiveness is expressed via dynamic experiments on various material systems. Single particle sand interaction along with glass cracking during dynamic compression, and fiber-epoxy interfacial failure, ligament-bone debonding, and single-crystal silicon fragmentation due to dynamic tension, were imaged with 0.5 {mu}s temporal resolution and {mu}m-level spatial resolution. Synchrotron x-ray phase contrast imaging of said material systems being loaded with the Kolsky bar apparatus demonstratively depicts the effectiveness of the novel union between these two powerful techniques, thereby allowing for in situ analysis of the interior of the material system during high-rate loading for a variety of applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗