Search NASA⌕ Search

Engineering topics

Chen, Yuting

Publications and source records attributed to Chen, Yuting.

Modified Eigen-Decomposition-based Interval Analysis (MEDIA) for Power System Dynamic State Estimation

The Bayesian approach has been used for the dynamic state estimation (DSE) of a power system. However, due to the complexity of noise resources, it is difficult to quantify measurement and process noise using probability density functions (PDFs). To overcome the difficulty, the authors of this paper propose a modified eigen-decomposition-based interval analysis (MEDIA) method, which employs bounds instead of PDFs to quantify the noise, and uses the eigen decomposition method to reduce the negative impact of the overestimation problem. Using the simulation data generated from IEEE 16-machine and IEEE 10-machine systems, it is shown that the proposed MEDIA method can estimate the hard boundaries of dynamic states in real time. Furthermore, comparison with the forward-backward propagation method and the extended set-membership filter also shows that the proposed MEDIA method performs better by providing narrower boundaries in the DSE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

B—N–Bond–Embedded Triplet Terpolymers with Small Singlet–Triplet Energy Gaps for Suppressing Non–Radiative Recombination and Improving Blend Morphology in Organic Solar Cells

Suppressing the photon energy loss (E loss ), especially the non-radiative loss, is of importance to further improve the device performance of organic solar cells (OSCs). However, typical π-conjugated semiconductors possess a large singlet–triplet energy gap (ΔE ST ), leading to a lower triplet state than charge transfer state and contributing to a non-radiative loss channel of the photocurrent by the triplet state. Herein, a series of triplet polymer donors are developed by introducing a BNIDT block into the PM6 polymer backbone. Further, the high electron affinity of BNIDT and the opposite resonance effect of the B—N bond in BNIDT results in a lowered highest occupied molecular orbital (HOMO) and a largely reduced ΔE ST . Moreover, the morphology of the active blends is also optimized by fine-tuning the BNIDT content. Therefore, non-radiative recombination via the terminal triplet loss channels and morphology traps is effectively suppressed. The PNB-3 (with 3% BNIDT):L8-BO device exhibits both small ΔE ST and optimized morphology, favoring more efficient charge transfer and transport. Finally, the simultaneously enhanced V oc of 0.907 V, J sc of 26.59 mA cm –2 , and FF of 78.86% contribute to a champion PCE of 19.02%. Therefore, introducing B—N bonds into benchmark polymers is a possible avenue toward higher-performance of OSCs.

36 MATERIALS SCIENCE↗

Multiplex base editing to convert $\mathrm{TAG}$ into $\mathrm{TAA}$ codons in the human genome

Whole-genome recoding has been shown to enable nonstandard amino acids, biocontainment and viral resistance in bacteria. Here we take the first steps to extend this to human cells demonstrating exceptional base editing to convert TAG to TAA for 33 essential genes via a single transfection, and examine base-editing genome-wide (observing ~40 C-to-T off-target events in essential gene exons). We also introduce GRIT, a computational tool for recoding. This demonstrates the feasibility of recoding, and highly multiplex editing in mammalian cells.

59 BASIC BIOLOGICAL SCIENCES↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Water heating energy use reductions from EPA WaterSense lavatory plumbing fittings

Hot water savings from water-efficient lavatory fittings lead to reductions in water heating energy consumption, and ultimately to decreases in carbon emissions. This paper characterizes existing and proposed approaches used to estimate hot water savings and carbon emissions reductions stemming from the U.S. Environmental Protection Agency's WaterSense program. Also described are refinements that improve the accuracy of residential hot water use percentage estimates of lavatory fittings. The authors conclude that (1) hot water percentages for showers and faucets calculated using up-to-date, publicly available national data are consistent with those found by regional studies and household-level models of water use; (2) the accuracy of heating energy savings estimates attributable to WaterSense-labeled lavatory products, as well as associated emissions reductions, can be refined by modifying the existing energy factor/uniform energy factor (EF/UEF)-based estimation approach with available data. The refined approach accounts for more nuanced conditions than the EF/UED-based approach but depends on data not always available; and (3) the approaches described and intermediate outputs can be generalized for other water conservation programs or estimating purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dishwashers in the Residential Sector: A Survey of Product Characteristics, Usage, and Consumer Preferences

Data on consumer purchasing decisions, usage, and behaviors relating to residential appliances help to inform technical and economic analyses related to the energy and water used by those appliances, including dishwashers. Existing publicly available data for dishwashers include two regularly conducted national surveys that describe dishwasher ownership and usage. The United States (US) Department of Energy’s (DOE) Energy Information Administration’s Residential Energy Consumption Survey (RECS) records the presence of a dishwasher in the home, the numbers of times per week the dishwasher is operated, and the dishwasher age, along with household demographic characteristics. The US Census Bureau’s American Housing Survey (AHS) also records the presence of a dishwasher in the home along with household demographic characteristics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calculating Average Hot Water Mixes of Residential Plumbing Fittings Using the ANSI 301-2019 Hot Water Draw Model and National Residential Data to Estimate Hot Water Use in Showerheads and Lavatory Faucets

Available studies of hot water use percentages may not necessarily be generalized to a national level given regional differences, varying methodological approaches, and limited sample sizes. While some publicly available usage data, reports, and surveys estimate actual household usage, a lack of water use data specific to end uses make more precise savings calculations difficult. Additionally, most hot water draw models tend to focus on overall household use and may not readily estimate lavatory fixture use. However, reviewing more recent studies and standards enables the U.S. Environmental Protection Agency’s WaterSense program to update its estimates for hot water use and consumers’ corresponding energy and monetary savings to better reflect realworld conditions. This report specifically focuses on improving hot water use and savings estimates of lavatory faucets and showerheads. To estimate the hot water use of lavatory faucets and showerheads, we employed the 2015 Residential Energy Consumption Surveys (RECS) microdata alongside the ANSI 301-2019 Hot Water Draw Model. These estimates account for regional differences in hot water use, including regional cold water inlet temperatures. As a result, the refinements presented in this report are more robust, more recent, and better describe the geographic variation than previous inputs used by the WaterSense program. In addition, the approach described in this paper can be updated over time or tailored to regionally specific needs given available inputs. We conclude that hot water percentages for showers and faucets calculated using publicly available national data are close to the percentages found by regional studies and are consistent with household-level models of water use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of linear regression modeling approaches on determining facility wide energy savings

Holistic energy management system business practices, such as the framework detailed in ISO 50001 – Energy management system, requirements and guidance for use , are centrally based upon the concept of energy performance improvement. For the purposes of ISO 50001, energy performance improvement can be determined for boundaries and following a process that is best suited for the implementing organization. Many organization and government ISO 50001 based programs, including the United States Department of Energy Superior Energy Performance (SEP) program, find value in demonstrating organizational energy performance improvement as the difference in energy consumption between two time periods within physically defined facility-boundaries. To make the difference in energy consumption for the two time periods meaningful, the amount of energy consumed must be adjusted to account for relevant variables. Relevant variables, such as metrics of production and weather conditions, affect directly the amount of energy consumed but are independent of the facility’s energy performance. Therefore, it is crucial to adjust the observed energy consumption by the relevant variables identified by the facility, so that the energy savings resulted from the energy performance improvement actions can be isolated and determined, which is the purpose of this program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for National Water Savings Model and Spreadsheet Tool—Outdoor Water Use

This report describes the method Lawrence Berkeley National Laboratory (LBNL) developed to estimate national impacts of the U.S. Environmental Protection Agency’s (EPA’s) WaterSense labeling program for weather-based irrigation controllers (WBIC). Estimated impacts include the national water savings attributable to the program and the net present value of the lifetime water savings for consumers of irrigation controllers.

Chen, Yuting↗

The Effect of Salts in Promoting Specific and Competitive Interactions between Zinc Finger Proteins and Metals

Specific protein–metal interactions (PMIs) fulfill essential functions in cells and organic bodies, and activation of these functions in vivo are mostly modulated by the complex environmental factors, including pH value, small biomolecules, and salts. Specifically, the role of salts in promoting specific PMIs and their competition among various metals has remained untapped mainly due to the difficulty to distinguish nonspecific PMIs from specific PMIs by classic spectroscopic techniques. Herein, we report Hofmeister salts differentially promote the specific PMIs by combining nanoelectrospray ionization mass spectrometry and spectroscopic techniques (fluorescence measurement and circular dichroism). Furthermore, to explore the influence of salts in competitive binding between metalloproteins and various metals, we designed a series of competitive experiments and applied to a well-defined model system, the competitive binding of zinc (II) and arsenic (III) to holo-promyelocytic leukemia protein (PML). These experiments not only provided new insights at the molecular scale as complementary to previous NMR and spectroscopic results, but also deduced the relative binding ability between zinc finger proteins and metals at the molecular scale, which avoids the mass spectrometric titration-based determination of binding constants that is frequently affected and often degraded by variable solution conditions including salt contents. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Keeping Pace With Water and Wastewater Rates

We present that water and wastewater treatment and delivery are the most capital-intensive of all utility services. The literature indicates that historically underpriced water and wastewater rates have exhibited steadily high growth in the past 15 years, while the consumer price index (CPI) of water and sewage maintenance has outpaced the general CPI by an increasingly wide margin. This article employs a chained analysis method to examine water and wastewater rates for a group of utilities across US Census regions between 2000 and 2014. Results demonstrate that water and wastewater prices for this sample group have consistently increased and have surpassed CPI growth since 2006. Finally, current and upcoming challenges facing water and wastewater utilities suggest that rate increases are likely to continue in the foreseeable future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water and Wastewater Rate Hikes Outpace CPI

Water and wastewater treatment and delivery is the most capital-intensive of all utility services. Historically underpriced, water and wastewater rates have exhibited unprecedented growth in the past fifteen years. Steep annual increases in water and wastewater rates that outpace the Consumer Price Index (CPI) have increasingly become the norm across the United States. In this paper, we analyze water and wastewater rates across U.S. census regions between 2000 and 2014. We also examine some of the driving factors behind these rate increases, including drought, water source, required infrastructure investment, population patterns, and conservation effects. Our results demonstrate that water and wastewater prices have consistently increased and have outstripped CPI throughout the study period nationwide, as well as within each census region. Further, evaluation of the current and upcoming challenges facing water and wastewater utilities suggests that sharp rate increases are likely to continue in the foreseeable future.

99 GENERAL AND MISCELLANEOUS↗

Methodology for Outdoor Water Savings Model and Spreadsheet Tool for U.S. and Selected States

Green lawns and landscaping are archetypical of the populated American landscape, and typically require irrigation, which corresponds to a significant fraction of residential, commercial, and institutional water use. In North American cities, the estimated portion of residential water used for outdoor purposes ranges from 22-38% in cooler climates up to 59-67% in dry and hot environments, while turfgrass coverage within the United States spans 11.1-20.2 million hectares (Milesi et al. 2009). One national estimate uses satellite and aerial photography data to develop a relationship between impervious surface and lawn surface area, yielding a conservative estimate of 16.4 (± 3.6) million hectares of lawn surface area in the United States—an area three times larger than that devoted to any irrigated crop (Milesi et al. 2005). One approach that holds promise for cutting unnecessary outdoor water use is the increased deployment of “smart” irrigation controllers to increase the water efficiency of irrigation systems. This report describes the methodology and inputs employed in a mathematical model that quantifies the effects of the U.S. Environmental Protection Agency’s WaterSense labeling program for one such type of controller, weather-based irrigation controllers (WBIC). This model builds off that described in “Methodology for National Water Savings Model and Spreadsheet Tool–Outdoor Water Use” and uses a two-tiered approach to quantify outdoor water savings attributable to the WaterSense program for WBIC, as well as net present value (NPV) of that savings. While the first iteration of the model assessed national impacts using averaged national values, this version begins by evaluating impacts in three key large states that make up a sizable portion of the irrigation market: California, Florida, and Texas. These states are considered to be the principal market of “smart” irrigation controllers that may result in the bulk of national savings. Modeled water savings and net present value for these three states should be more accurate and representative than the averaged national values given state-specific inputs such as lot size, water price, and housing stock. To complete the picture of national impacts, the remaining WBIC shipments not assigned to these three states are assessed using the original methodology based on the averaged national values.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to some extent, the operating hours of the studied units. Specifically, the primary objectives of the field-metering study were to (1) expand knowledge of the installation, energy consumption profiles, consumer patterns of use, and environmental parameters related to PAC use; (2) develop distributions of hours of PAC operation for three operating modes: standby, 1 fan-only, and cooling; and (3) describe how individual consumers’ selection of PAC capacity, the area of the space to be cooled, the temperature set point, and environmental conditions affect energy use. Beginning to understand the energy consumption of PACs operating in American homes and commercial settings will help develop a more accurate energy use profile that characterizes relevant variables. This report on LBNL’s field-metering study of PAC energy use describes: a general definition of a PAC and how it operates (section 2); current practices and sources of data for estimating PAC energy use (section 3); the process LBNL used to select field-metering sites, along with characteristics of the sites and the PACs studied (section 4); data collection methods and instrumentation (section 5); analysis methods (section 6); results and discussion (section 7); and conclusions (section 8).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗