Search NASA⌕ Search

Engineering topics

Chin, D. A. (ORCID:0000000301187690)

Publications and source records attributed to Chin, D. A. (ORCID:0000000301187690).

Parametrized ion-distribution model for extended x-ray absorption fine-structure analysis at high-energy-density conditions

Experiments today can compress solids near isentropically to pressures approaching 100 × 106 atmospheres; however, determining the temperature of such matter remains a major challenge. Extended x-ray absorption fine-structure (EXAFS) spectroscopy is one of the few techniques sensitive to the bulk temperature of highly compressed solid matter, and the validity of this temperature measurement relies on constraining the local ion structure from the EXAFS spectrum. At high-energy-density (HED) conditions, the local ion structure often becomes distorted, which must be accounted for during the EXAFS analysis. Described here is a technique, using a parametrized ion-distribution model to directly analyze EXAFS spectra that provides a better constraint on the local structure than traditional second- or third-order cumulant expansion techniques at HED conditions. The parametrized ion-distribution model is benchmarked by analyzing EXAFS spectra from nickel molecular-dynamics simulations at ∼100 GPa and shown to provide a 10%–20% improvement in constraining the cumulants of the true ion distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron-beam-based Compton scattering x-ray source for probing high-energy-density physics

The physics basis for an electron-beam-based Compton scattering x-ray source is investigated for single-shot experiments at the major high-energy-density facilities, such as the Omega Laser Facility, National Ignition Facility, and Z pulsed power facility. A source of monoenergetic ( δ ε / ε < 5 % ) 10- to 50-keV x rays can be produced by scattering of a short-pulse optical laser by a 23- to 53-MeV electron beam and collimating the scattered photons. The number and spectrum of scattered photons are calculated as a function of electron packet charge, electron and laser pulse duration, laser intensity, and collision geometry. A source delivering greater than 10 10 photons in a 1-mm-radius spot and 100-ps time resolution is plausible with the available electron gun and laser technology. Applications of this source for x-ray diffraction, x-ray imaging, x-ray absorption fine structure, and x-ray absorption spectroscopy in high-energy-density physics experiments are described, demonstrating significant advancements compared to the present state of the art. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Ionization disequilibrium in K- and L-shell ions

Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission phases of implosion sources for x-ray absorption fine structure spectroscopy

At the Laboratory for Laser Energetics' Omega Laser Facility, thin plastic shells were directly driven with ∼20 kJ resulting in a time-integrated x-ray yield of ∼1012 ph/eV/sr at 7 keV. Using temporally, spatially, and spectrally discriminating diagnostics, three x-ray emission phases were identified: corona emission produced by the laser ablation of the shell, core stagnation, and afterglow emission due to the expanding hot material after stagnation. The newly measured corona and afterglow emission phases account for ∼25% of the total x-ray signal and produce x-ray emission at a different time or larger radius than previously considered. The resulting implications of this additional emission for x-ray absorption fine structure spectroscopy are discussed. Finally, improvements to the laser drive intensity and uniformity produced a factor-of-2 increase in total x-ray emission while decreasing the size of the stagnated core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗