Search NASAβŒ• Search

Engineering topics

Chiu, M.

Publications and source records attributed to Chiu, M..

At least 19 records

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 Β΅Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Erratum: Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at $\sqrt{𝑠_{𝑁⁒𝑁}}$ = 200 GeV [Phys. Rev. Lett. 116, 122301 (2016)]

We previously reported jet-production rates in 𝑝 + 𝑝 and 𝑑 + Au collisions at $\sqrt{𝑠_{𝑁⁒𝑁}}$ = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Subsequently, we found that electronic noise in the electromagnetic calorimeter was not completely removed by the tower-timing cuts used in the analysis. We have conducted an independent re-analysis of the data that eliminated noisy towers by removing them completely from the analysis. These cuts remove any contributions from instrumental noise, but reduce the overall acceptance for electromagnetic clusters by β‰ˆ16% and hence the overall statistical power of the data. Finally, this re-analysis found that instrumental noise in the electromagnetic calorimeter led to an artificial increase in the jet yield for both the 𝑝 + 𝑝 and 𝑑 + Au collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Jet modification via πœ‹ 0 -hadron correlations in Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV

High-momentum two-particle correlations are a useful tool for studying jet-quenching effects in the quark-gluon plasma. Angular correlations between neutral-pion triggers and charged hadrons with transverse momenta in the range 4–12 GeV/𝑐 and 0.5–7 GeV/𝑐, respectively, have been measured by the PHENIX experiment in 2014 for Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV. Suppression is observed in the yield of high-momentum jet fragments opposite the trigger particle, which indicates jet suppression stemming from in-medium partonic energy loss, while enhancement is observed for low-momentum particles. The ratio and differences between the yield in Au + Au collisions and 𝑝 + 𝑝 collisions, 𝐼 𝐴⁒𝐴 and Ξ” 𝐴⁒𝐴 , as a function of the trigger-hadron azimuthal separation, Ξ”β’πœ™, are measured for the first time at the BNL Relativistic Heavy Ion Collider. Finally, these results better quantify how the yield of low-𝑝 𝑇 associated hadrons is enhanced at wide angle, which is crucial for studying energy loss as well as medium-response effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identified charged-hadron production in 𝑝+Al, 3 He + Au, and Cu + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV and in U + U collisions at $\sqrt{s_{NN}}$ = 193 GeV

The PHENIX experiment has performed a systematic study of identified charged-hadron (πœ‹ Β± , 𝐾 Β± , 𝑝, $\bar{𝑝}$) production at midrapidity in 𝑝 + Al, 3 He + Au, and Cu + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV and U + U collisions at $\sqrt{s_{NN}}$ = 193 GeV. Identified charged-hadron invariant transverse-momentum (𝑝 𝑇 ) and transverse-mass (π‘š 𝑇 ) spectra are presented and interpreted in terms of radially expanding thermalized systems. The particle ratios of 𝐾/πœ‹ and 𝑝/πœ‹ have been measured in different centrality ranges of large (Cu + Au and U + U) and small (𝑝 + Al and 3 He + Au) collision systems. The values of 𝐾/πœ‹ ratios measured in all considered collision systems were found to be consistent with those measured in 𝑝+𝑝 collisions. However, the values of 𝑝/πœ‹ ratios measured in large collision systems reach the values of β‰ˆ0.6, which is a factor of β‰ˆ2 larger than in 𝑝 + 𝑝 collisions. These results can be qualitatively understood in terms of the baryon enhancement expected from hadronization by recombination. Identified charged-hadron nuclear-modification factors (𝑅 𝐴⁒𝐡 ) are also presented. Enhancement of proton 𝑅 𝐴⁒𝐡 values over meson 𝑅 𝐴⁒𝐡 values was observed in central 3 He + Au, Cu + Au, and U + U collisions. Finally, the proton 𝑅 𝐴⁒𝐡 values measured in the 𝑝 + Al collision system were found to be consistent with 𝑅 𝐴⁒𝐡 values of πœ™, πœ‹ Β± , 𝐾 Β± , and πœ‹ 0 mesons, which may indicate that the size of the system produced in 𝑝 + Al collisions is too small for recombination to cause a noticeable increase in proton production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonprompt direct-photon production in Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV

The measurement of the direct-photon spectrum from Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV is presented by the PHENIX Collaboration using the external-photon-conversion technique for 0%–93% central collisions in a transverse-momentum (𝑝 𝑇 ) range of 0.8–10 GeV/𝑐. An excess of direct photons, above prompt-photon production from hard-scattering processes, is observed for 𝑝 𝑇 < 6 GeV/𝑐. Nonprompt direct photons are measured by subtracting the prompt component, which is estimated as 𝑁 coll -scaled direct photons from 𝑝 + 𝑝 collisions at 200 GeV, from the direct-photon spectrum. Results are obtained for 0.8 < 𝑝 𝑇 < 6.0 GeV/𝑐 and suggest that the spectrum has an increasing inverse slope from β‰ˆ0.2 to 0.4 GeV/𝑐 with increasing 𝑝 𝑇 , which indicates a possible sensitivity of the measurement to photons from earlier stages of the evolution of the collision. In addition, like the direct-photon production, the 𝑝 𝑇 -integrated nonprompt direct-photon yields also follow a power-law scaling behavior as a function of collision-system size. Finally, the exponent, 𝛼, for the nonprompt component is found to be consistent with 1.1 with no apparent 𝑝 𝑇 dependence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charm- and bottom-quark production in Au+Au collisions at $$ \sqrt{{\textrm{s}}_{\textrm{NN}}} $$=200 GeV

Here, the invariant yield of electrons from open-heavy-flavor decays for 1 < p T < 8 GeV/c at midrapidity |y| < 0.35 in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV has been measured by the PHENIX experiment at the Relativistic Heavy Ion Collider. A displaced-vertex analysis with the PHENIX silicon-vertex detector enables extraction of the fraction of charm and bottom hadron decays and unfolding of the invariant yield of parent charm and bottom hadrons. The nuclear-modification factors RAA for electrons from charm and bottom hadron decays and heavy-flavor hadrons show both a centrality and a quark-mass dependence, indicating suppression in the quark-gluon plasma produced in these collisions that is medium sized and quark-mass dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Erratum: LΓ©vy-stable two-pion Bose-Einstein correlations in s N N = 200 GeV Au + Au collisions [Phys. Rev. C 97 , 064911 (2018)]

We previously published in 2018 a detailed measurement recorded in 2010 for Au+Au collisions at $\sqrt{^SNN}$ = 200 GeV of charged two-pion correlation functions in 0%-30% centrality. We found the data to be well described by Bose-Einstein correlation functions stemming from L$\acute{e}$vy-stable source distributions. Using a fine transverse momentum binning, we extracted the correlation strength parameter Ξ», the L$\acute{e}$vy index of stability Ξ± and the L$\acute{e}$vy length scale parameter R as a function of average transverse mass of the pair m T .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 Γ— 41 GeV 2 and 18 Γ— 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<Ξ·<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. Furthermore, this paper describes this database application, explains how it functions, and discusses how it streamlines the design of the experiment.

47 OTHER INSTRUMENTATION↗