Search NASA⌕ Search

Engineering topics

Cho, Kwan Ho

Publications and source records attributed to Cho, Kwan Ho.

Locoregional Recurrence of Breast Cancer in Patients Treated With Breast Conservation Surgery and Radiotherapy Following Neoadjuvant Chemotherapy

Purpose: Breast conservation surgery (BCS) and radiotherapy (RT) following neoadjuvant chemotherapy (NCT) have been linked with high locoregional recurrence (LRR) rates and ipsilateral breast tumor recurrence (IBTR) rates. The purpose of this study was to analyze clinical outcomes in patients who exhibited LRR and IBTR after being treated by BCS and RT following NCT. Methods and Materials: In total, 251 breast cancer patients treated with BCS and RT following NCT between 2001 and 2006 were included. All patients had been shown to be clinically node-positive. Clinical stage at diagnosis (2003 AJCC) was II in 68% of patients and III in 32% of patients. Of those, 50%, 35%, and 15% of patients received anthracycline-based, taxane-based, and combined anthracycline-taxane NCT, respectively. All patients received RT. Results: During follow-up (median, 55 months), 26 (10%) patients had LRR, 19 of these patients had IBTR. Five-year actuarial rates of IBTR-free and LRR-free survival were 91% and 89%, respectively. In multivariate analyses, lack of hormone suppression therapy was found to increase both LRR and IBTR rates. Hazard ratios were 7.99 (p < 0.0001) and 4.22 (p = 0.004), respectively. Additionally, pathology stage N2 to N3 increased LRR rate (hazard ratio, 4.22; p = 0.004), and clinical AJCC stage III IBTR rate (hazard ratio, 9.05; p = 0.034). Achievement of pathological complete response and presence of multifocal tumors did not affect LRR or IBTR. Conclusions: In patients with locally advanced disease, who were clinically node-positive at presentation, BCS after NCT resulted in acceptably low rates of IBTR and LRR. Mastectomy should be considered as an option in patients who present with clinical stage III tumors or who are not treated with adjuvant hormone suppression therapy, because they exhibit high IBTR rates after NCT and BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Positron Emission Tomography-Staged Clinical N3 Breast Cancer Treated With Neoadjuvant Chemotherapy, Surgery, and Radiotherapy

Purpose: To evaluate the treatment outcome and efficacy of regional lymph node irradiation after neoadjuvant chemotherapy (NCT) and surgery in positron emission tomography (PET)-positive clinical N3 (cN3) breast cancer patients. Methods and Materials: A total of 55 patients with ipsilateral infraclavicular (ICL), internal mammary (IMN), or supraclavicular (SCL) lymph node involvement in the absence of distant metastases, as revealed by an initial PET scan, were retrospectively analyzed. The clinical nodal stage at diagnosis (2002 AJCC) was cN3a in 14 patients (26%), cN3b in 12 patients (22%), and cN3c in 29 patients (53%). All patients were treated with NCT, followed by mastectomy or breast-conserving surgery and subsequent radiotherapy (RT) with curative intent. Results: At the median follow-up of 38 months (range, 9-80 months), 20 patients (36%) had developed treatment failures, including distant metastases either alone or combined with locoregional recurrences that included one ipsilateral breast recurrence (IBR), six regional failures (RF), and one case of combined IBR and RF. Only 3 patients (5.5%) exhibited treatment failure at the initial PET-positive clinical N3 lymph node. The 5-year locoregional relapse-free survival, disease-free survival (DFS), and overall survival rates were 80%, 60%, and 79%, respectively. RT delivered to PET-positive IMN regions in cN3b patients and at higher doses ({>=}55 Gy) to SCL regions in cN3c patients was not associated with improved 5-year IMN/SCL relapse-free survival or DFS. Conclusion: NCT followed by surgery and RT, including the regional lymph nodes, resulted in excellent locoregional control for patients with PET-positive cN3 breast cancer. The primary treatment failure in this group was due to distant metastasis rather than RF. Neither higher-dose RT directed at PET-positive SCL nodes nor coverage of PET-positive IMN nodes was associated with additional gains in locoregional control or DFS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of a Contrast Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Patients With Locoregionally Advanced Lung Cancer

Purpose: We evaluated the effect of a contrast agent (CA) on proton beam range in a treatment planning system (TPS) for patients with locoregionally advanced lung cancer. Methods and Materials: Two sets of computed tomography (CT) images (with and without CA) were obtained from 20 patients with lung cancer. Because the increase in Hounsfield unit ( Increment HU) value of the heart and great vessels due to the effect of CA is most prominent among thoracic structures, to evaluate the effect of CA on proton beam range in the TPS, we compared the calculated distal ranges in the plan with CA-enhanced CT with those with corrected CT, in which the HU values of the heart and great vessels in the CA-enhanced CT were replaced by average HU values obtained from the unenhanced CT. Results: The mean Increment HU value and the longest length of the heart and great vessels within the proton beam path in the field that passed through these structures were 189 {+-} 29 HU (range, 110-250 HU) and 7.1 {+-} 1.1 cm (range, 2.6-11.2 cm), respectively. The mean distal range error in the TPS because of the presence of CA was 1.0 {+-} 0.7 cm (range, 0.2-2.6 cm). Conclusion: If CA-enhanced CT images are used for radiotherapy planning using a proton beam for the treatment of lung cancer, our results suggest that the HU values of the heart and great vessels should be replaced by the average HU values of soft tissue to avoid discrepancies between planned and delivered doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment-Related Pneumonitis and Acute Esophagitis in Non-Small-Cell Lung Cancer Patients Treated With Chemotherapy and Helical Tomotherapy

Purpose: To assess clinical outcomes and complications in patients with non-small-cell lung cancer (NSCLC) treated with helical tomotherapy (HT) with or without chemotherapy. Methods and Materials: Data from 37 NSCLC patients treated between January 2007 and August 2008 were analyzed retrospectively. Twenty-eight patients had Stage III disease. Concurrent and neoadjuvant chemotherapy was given to 24 and 14 patients, respectively. Radiotherapy was delivered to a total dose of 60-70.4 Gy at 2.0-2.4 Gy per fraction to the gross tumor volume and 50-64 Gy at 1.8-2.0 Gy per fraction to the planning target volume. Results: With a median follow-up of 18 months (range, 6-27 months), 2-year local control and overall survival rates were 63% and 56% for all 37 patients, respectively, and were 78% and 75% for the patients with Stage III disease who received concurrent chemoradiotherapy alone. Acute esophagitis and treatment-related pneumonitis (TRP) {>=}Grade 3 occurred in 5 and 7 patients, respectively. Four patients died of treatment-related death (TRD) after HT. In univariate analysis, poor performance status, total lung V{sub 5}, contralateral lung (CL) V{sub 5}, and V{sub 10} were associated with TRD. Only CL V{sub 5} remained significant in the multivariate analysis (p = 0.029). Conclusions: HT with chemotherapy has shown promising clinical outcomes, esophagitis, and TRPs. However, HT has produced a somewhat high rate of fatal pulmonary complications. Our data suggest that CL V{sub 5} should be considered and kept as low as possible (<60%) in addition to the conventional dosimetric factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Cancers From Modern Radiotherapy Techniques: Intensity-Modulated Radiotherapy Versus Proton Therapy

Purpose: To assess and compare secondary cancer risk resulting from intensity-modulated radiotherapy (IMRT) and proton therapy in patients with prostate and head-and-neck cancer. Methods and Materials: Intensity-modulated radiotherapy and proton therapy in the scattering mode were planned for 5 prostate caner patients and 5 head-and-neck cancer patients. The secondary doses during irradiation were measured using ion chamber and CR-39 detectors for IMRT and proton therapy, respectively. Organ-specific radiation-induced cancer risk was estimated by applying organ equivalent dose to dose distributions. Results: The average secondary doses of proton therapy for prostate cancer patients, measured 20-60cm from the isocenter, ranged from 0.4 mSv/Gy to 0.1 mSv/Gy. The average secondary doses of IMRT for prostate patients, however, ranged between 3 mSv/Gy and 1 mSv/Gy, approximately one order of magnitude higher than for proton therapy. Although the average secondary doses of IMRT were higher than those of proton therapy for head-and-neck cancers, these differences were not significant. Organ equivalent dose calculations showed that, for prostate cancer patients, the risk of secondary cancers in out-of-field organs, such as the stomach, lungs, and thyroid, was at least 5 times higher for IMRT than for proton therapy, whereas the difference was lower for head-and-neck cancer patients. Conclusions: Comparisons of organ-specific organ equivalent dose showed that the estimated secondary cancer risk using scattering mode in proton therapy is either significantly lower than the cases in IMRT treatment or, at least, does not exceed the risk induced by conventional IMRT treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of Movement-Induced Dose Reduction in Target Volume: A Comparison Between Photon and Proton Beam Treatment

We compared the main characteristics of movement-induced dose reduction during photon and proton beam treatment, based on an analysis of dose-volume histograms. To simulate target movement, a target contour was delineated in a scanned phantom and displaced by 3 to 20 mm. Although the dose reductions to the target in the 2 treatment systems were similar for transverse (perpendicular to beam direction) target motion, they were completely different for longitudinal (parallel to beam direction) target motion. While both modalities showed a relationship between the degree of target shift and the reduction in dose coverage, dose reduction showed a strong directional dependence in proton beam treatment. Clinical simulation of target movement for a prostate cancer patient showed that, although coverage and conformity indices for a 6-mm lateral movement of the prostate were reduced by 9% and 16%, respectively, for proton beam treatment, they were reduced by only 1% and 7%, respectively, for photon treatment. This difference was greater for a 15-mm target movement in the lateral direction, which lowered the coverage and conformity indices by 34% and 54%, respectively, for proton beam treatment, but changed little during photon treatment. In addition, we found that the equivalent uniform dose (EUD) and homogeneity index show similar characteristics during target movement. These results suggest that movement-induced dose reduction differs significantly between photon and proton beam treatment. Attention should be paid to the target margin in proton beam treatment due to the distinct characteristics of heavy ion beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microscopic Gold Particle-Based Fiducial Markers for Proton Therapy of Prostate Cancer

Purpose: We examined the feasibility of using fiducial markers composed of microscopic gold particles and human-compatible polymers as a means to overcome current problems with conventional macroscopic gold fiducial markers, such as dose reduction and artifact generation, in proton therapy for prostate cancer. Methods and Materials: We examined two types of gold particle fiducial marker interactions: that with diagnostic X-rays and with a therapeutic proton beam. That is, we qualitatively and quantitatively compared the radiographic visibility of conventional gold and gold particle fiducial markers and the CT artifacts and dose reduction associated with their use. Results: The gold particle fiducials could be easily distinguished from high-density structures, such as the pelvic bone, in diagnostic X-rays but were nearly transparent to a proton beam. The proton dose distribution was distorted <5% by the gold particle fiducials with a 4.9% normalized gold density; this was the case even in the worst configuration (i.e., parallel alignment with a single-direction proton beam). In addition, CT artifacts were dramatically reduced for the gold particle mixture. Conclusion: Mixtures of microscopic gold particles and human-compatible polymers have excellent potential as fiducial markers for proton therapy for prostate cancer. These include good radiographic visibility, low distortion of the depth-dose distribution, and few CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Secondary Neutron Doses for Several Beam Configurations for Proton Therapy

Purpose: To compare possible neutron doses produced in scanning and scattering modes, with the latter assessed using a newly built passive-scattering proton beam line. Methods and Materials: A 40 x 30.5 x 30-cm water phantom was irradiated with 230-MeV proton beams using a gantry angle of 270{sup o}, a 10-cm-diameter snout, and a brass aperture with a diameter of 7 cm and a thickness of 6.5 cm. The secondary neutron doses during irradiation were measured at various points using CR-39 detectors, and these measurements were cross-checked using a neutron survey meter with a 22-cm range and a 5-cm spread-out Bragg peak. Results: The maximum doses due to secondary neutrons produced by a scattering beam-delivery system were on the order of 0.152 mSv/Gy and 1.17 mSv/Gy at 50 cm from the beam isocenter in the longitudinal (0{sup o}) and perpendicular (90{sup o}) directions, respectively. The neutron dose equivalent to the proton absorbed dose, measured from 10 cm to 100 cm from the isocenter, ranged from 0.071 mSv/Gy to 1.96 mSv/Gy in the direction of the beam line (i.e., {phi} = 0 deg.). The largest neutron dose, of 3.88 mSv/Gy, was observed at 135{sup o} and 25 cm from the isocenter. Conclusions: Although the secondary neutron doses in proton therapy were higher when a scattering mode rather than a scanning mode was used, they did not exceed the scattered photon dose in typical photon treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATM is required for rapid degradation of cyclin D1 in response to {gamma}-irradiation

The cellular response to DNA damage induced by {gamma}-irradiation activates cell-cycle arrest to permit DNA repair and to prevent replication. Cyclin D1 is the key molecule for transition between the G1 and S phases of the cell-cycle, and amplification or overexpression of cyclin D1 plays pivotal roles in the development of several human cancers. To study the regulation of cyclin D1 in the DNA-damaged condition, we analyzed the proteolytic regulation of cyclin D1 expression upon {gamma}-irradiation. Upon {gamma}-irradiation, a rapid reduction in cyclin D1 levels was observed prior to p53 stabilization, indicating that the stability of cyclin D1 is controlled in a p53-independent manner. Further analysis revealed that irradiation facilitated ubiquitination of cyclin D1 and that a proteasome inhibitor blocked cyclin D1 degradation under the same conditions. Interestingly, after mutation of threonine residue 286 of cyclin D1, which is reported to be the GSK-3{beta} phosphorylation site, the mutant protein showed resistance to irradiation-induced proteolysis although inhibitors of GSK-3{beta} failed to prevent cyclin D1 degradation. Rather, ATM inhibition markedly prevented cyclin D1 degradation induced by {gamma}-irradiation. Our data indicate that communication between ATM and cyclin D1 may be required for maintenance of genomic integrity achieved by rapid arrest of the cell-cycle, and that disruption of this crosstalk may increase susceptibility to cancer.

60 APPLIED LIFE SCIENCES↗

Influence of Lipiodol Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Hepatocellular Carcinoma

Purpose: To evaluate the influence of lipiodol on the proton beam range, which has not yet been determined. Methods and Materials: Two computed tomography (CT) data sets were obtained with a T25-flask containing lipiodol and water that was placed above a water phantom. The plan with the lipiodol CT images was performed, and then a verification plan was applied to the water CT images. The actual proton beam ranges in the lipiodol and water were measured under same conditions, and we compared the calculated proton beam range in the treatment planning system with measured values. Results: The calculated distal range in the treatment planning system was 12 cm in water, which was 3.87 cm longer than that in lipiodol (8.13 cm). In contrast, the measured distal range was 12 {+-} 0.01 cm in water, which was 0.21 {+-} 0.01 cm longer than that of lipiodol (11.78 {+-} 0.01 cm). A 3.65 {+-} 0.01-cm range shift was found in the calculated range compared with the measured range. For 10 hepatocellular carcinoma patients, the distal range in the verification plan with the corrected CT images in which the Hounsfield unit (HU) value of lipiodolized lesion was replaced with the average HU value of the surrounding tissue was 0.61 {+-} 0.26 cm (range, 0.26-0.99) longer than that in the plan with uncorrected CT images. Conclusions: It could be relevant for the purposes of range calculation of proton beams in the treatment planning system that the HU value of a lipiodolized lesion is replaced by the average HU value of the surrounding normal tiss0008.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computerized tomography-based quality assurance tool for proton range compensators

The authors have developed an automatic quality assurance method based on computerized tomography (CT) data for physically manufactured proton range compensators. Eight range compensators used for proton therapy at their institution were scanned using CT and their depth distributions were compared with data provided by a proton treatment planning system (TPS). The depth difference (DD), distance to agreement (DTA), and a composite analysis (CA) indicating regions that passed either of the tests were used for depth verification. When the tolerance limits were set at 3 mm for DD and 1 mm for DTA, the average percentages of points exceeding the acceptance criteria for DD, DTA, and CA for the eight compensators were 9.0%, 5.3% and 3.2%, respectively. In general, the percentages of points exceeding the acceptance criteria were much higher in DD than in DTA analysis and mismatch of depth was greater in regions with high depth gradients. This is considered to arise mainly because of systematic errors such as the physical size of the drill, slight bending or slipping of the drill bit near high gradient regions, the limit of CT resolution, and the uncertainty in CT number. When the tolerance limit of DTA was increased from 1 to 2 mm, the average percentage of points exceeding the acceptance criteria for DTA was reduced from 5.3% to 0.9%. Their results show that depth comparison of proton range compensators based on CT images can provide more systematic data than does the current method, in which a representative group of drill points is measured manually.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafractional Movement-Induced Dose Reduction of Prostate Target Volume in Proton Beam Treatment

Purpose: To quantify proton radiotherapy dose reduction in the prostate target volume because of the three-dimensional movement of the prostate based on an analysis of dose-volume histograms (DVHs). Methods and Materials: Twelve prostate cancer patients underwent scanning in supine position, and a target contour was delineated for each using a proton treatment planning system. To simulate target movement, the contour was displaced from 3 to 15 mm in 3-mm intervals in the superior-to-inferior (SI), inferior-to-superior (IS), anterior-to-posterior (AP), posterior-to-anterior (PA), and left-to-right (LR) directions. Results: For both intra- and interfractional movements, the average coverage index and conformity index of the target were reduced in all directions. For interfractional movements, the magnitude of dose reduction was greater in the LR direction than in the AP, PA, SI. and IS directions. Although the reduction of target dose was proportional to the magnitude of intrafractional movement in all directions, a proportionality between dose reduction and the magnitude of interfractional target movement was clear only in the LR direction. Like the coverage index and conformity index, the equivalent uniform dose and homogeneity index showed similar reductions for both types of target movements. Conclusions: Small target movements can significantly reduce target proton radiotherapy dose during treatment of prostate cancer patients. Attention should be given to interfractional target movement along the longitudinal direction, as image-guided radiotherapy may be ineffective if margins are not sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗