Search NASA⌕ Search

DOE OSTI · 21120876

Computerized tomography-based quality assurance tool for proton range compensators

Abstract

The authors have developed an automatic quality assurance method based on computerized tomography (CT) data for physically manufactured proton range compensators. Eight range compensators used for proton therapy at their institution were scanned using CT and their depth distributions were compared with data provided by a proton treatment planning system (TPS). The depth difference (DD), distance to agreement (DTA), and a composite analysis (CA) indicating regions that passed either of the tests were used for depth verification. When the tolerance limits were set at 3 mm for DD and 1 mm for DTA, the average percentages of points exceeding the acceptance criteria for DD, DTA, and CA for the eight compensators were 9.0%, 5.3% and 3.2%, respectively. In general, the percentages of points exceeding the acceptance criteria were much higher in DD than in DTA analysis and mismatch of depth was greater in regions with high depth gradients. This is considered to arise mainly because of systematic errors such as the physical size of the drill, slight bending or slipping of the drill bit near high gradient regions, the limit of CT resolution, and the uncertainty in CT number. When the tolerance limit of DTA was increased from 1 to 2 mm, the average percentage of points exceeding the acceptance criteria for DTA was reduced from 5.3% to 0.9%. Their results show that depth comparison of proton range compensators based on CT images can provide more systematic data than does the current method, in which a representative group of drill points is measured manually.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yoon, Myonggeun, Kim, Jin-Sung, Shin, Dongho, Park, Sung Yong, Lee, Se Byeong, Kim, Dae Yong, Kim, Taehyun, Shin, Kyung Hwan, Cho, Kwan Ho. 2008-08-15. Computerized tomography-based quality assurance tool for proton range compensators. https://doi.org/10.1118/1.2952645. https://searchnasa.com/record/osti%3A21120876/computerized-tomography-based-quality-assurance-tool-for-proton-range-compensators

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗