Search NASA⌕ Search

Engineering topics

Shin, Kyung Hwan

Publications and source records attributed to Shin, Kyung Hwan.

Targeting Phosphatidylinositol 4-Kinase IIIα for Radiosensitization: A Potential Model of Drug Repositioning Using an Anti-Hepatitis C Viral Agent

Purpose: To investigate which isotype of phosphatidylinositol 4-kinase (PI4K) may affect radiosensitivity and examine whether anti–hepatitis C viral (HCV) agents, some of which have been shown to inhibit PI4K IIIα activity, could be repositioned as a radiosensitizer in human cancer cells. Methods and Materials: U251, BT474, and HepG2 cell lines and normal human astrocyte were used. Ribonucleic acid interference, clonogenic assays, Western blotting, immunofluorescence, annexin V assay, lysotracker staining, and β-galactosidase assay were performed. Results: Of the 4 PI4K isotypes, specific inhibition of IIIα increased radiosensitivity. For pharmacologic inhibition of PI4K IIIα, we screened 9 anti-HCV agents by half-maximal inhibitory concentration assay. Simeprevir was selected, and its inhibition of PI4K IIIα activity was confirmed. Combination of simeprevir treatment and radiation significantly attenuated expression of phospho-phospho-PKC and phospho-Akt and increased radiation-induced cell death in tested cell lines. Pretreatment with simeprevir prolonged γH2AX foci formation and down-regulation of phospho-DNA-PKcs, indicating impairment of nonhomologous end-joining repair. Cells pretreated with simeprevir exhibited mixed modes of cell death, including apoptosis and autophagy. Conclusion: These data demonstrate that targeting PI4K IIIα using an anti-HCV agent is a viable approach to enhance the therapeutic efficacy of radiation therapy in various human cancers, such as glioma, breast, and hepatocellular carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dummy Run of Quality Assurance Program in a Phase 3 Randomized Trial Investigating the Role of Internal Mammary Lymph Node Irradiation in Breast Cancer Patients: Korean Radiation Oncology Group 08-06 Study

Purpose: The Korean Radiation Oncology Group (KROG) 08-06 study protocol allowed radiation therapy (RT) technique to include or exclude breast cancer patients from receiving radiation therapy to the internal mammary lymph node (IMN). The purpose of this study was to assess dosimetric differences between the 2 groups and potential influence on clinical outcome by a dummy run procedure. Methods and Materials: All participating institutions were asked to produce RT plans without irradiation (Arm 1) and with irradiation to the IMN (Arm 2) for 1 breast-conservation treatment case (breast-conserving surgery [BCS]) and 1 mastectomy case (modified radical mastectomy [MRM]) whose computed tomography images were provided. We assessed interinstitutional variations in IMN delineation and evaluated the dose-volume histograms of the IMN and normal organs. A reference IMN was delineated by an expert panel group based on the study guidelines. Also, we analyzed the potential influence of actual dose variation observed in this study on patient survival. Results: Although physicians intended to exclude the IMN within the RT field, the data showed almost 59.0% of the prescribed dose was delivered to the IMN in Arm 1. However, the mean doses covering the IMN in Arm 1 and Arm 2 were significantly different for both cases (P<.001). Due to the probability of overdose in Arm 1, the estimated gain in 7-year disease-free survival rate would be reduced from 10% to 7.9% for BCS cases and 7.1% for MRM cases. The radiation doses to the ipsilateral lung, heart, and coronary artery were lower in Arm 1 than in Arm 2. Conclusions: Although this dummy run study indicated that a substantial dose was delivered to the IMN, even in the nonirradiation group, the dose differences between the 2 groups were statistically significant. However, this dosimetric profile should be studied further with actual patient samples and be taken into consideration when analyzing clinical outcomes according to IMN irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Postmastectomy Radiation Therapy After Neoadjuvant Chemotherapy in Clinical Stage II-III Breast Cancer Patients With pN0: A Multicenter, Retrospective Study (KROG 12-05)

Purpose: The purpose of this study was to investigate the role of postmastectomy radiation therapy (PMRT) after neoadjuvant chemotherapy (NAC) in clinical stage II-III breast cancer patients with pN0. Methods and Materials: We retrospectively identified 417 clinical stage II-III breast cancer patients who achieved an ypN0 at surgery after receiving NAC between 1998 and 2009. Of these, 151 patients underwent mastectomy after NAC. The effect of PMRT on disease-free survival (DFS), locoregional recurrence-free survival (LRRFS), and overall survival (OS) was evaluated by multivariate analysis including known prognostic factors using the Kaplan-Meier method and compared using the log–rank test and Cox proportional regression analysis. Results: Of the 151 patients who underwent mastectomy, 105 (69.5%) received PMRT and 46 patients (30.5%) did not. At a median follow-up of 59 months, 5 patients (3.3%) developed LRR (8 sites of recurrence) and 14 patients (9.3%) developed distant metastasis. The 5-year DFS, LRRFS, and OS rates were 91.2, 98.1, and 93.3% with PMRT and 83.0%, 92.3%, and 89.9% without PMRT, respectively (all P values not significant). By univariate analysis, only age (≤40 vs >40 years) was significantly associated with decreased DFS (P=.027). By multivariate analysis, age (≤40 vs >40 years) and pathologic T stage (0-is vs 1 vs 2-4) were significant prognostic factors affecting DFS (hazard ratio [HR] 0.353, 95% confidence interval [CI] 0.135-0.928, P=.035; HR 2.223, 95% CI 1.074-4.604, P=.031, respectively). PMRT showed no correlation with a difference in DFS, LRRFS, or OS by multivariate analysis. Conclusions: PMRT might not be necessary for pN0 patients after NAC, regardless of clinical stage. Prospective randomized clinical trial data are needed to assess whether PMRT can be safely omitted in pN0 patients after NAC and mastectomy for clinical stage II-III breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Carbohydrate Antigen 19-9 Level Indicates Tumor Response, Early Distant Metastasis, Overall Survival, and Therapeutic Selection in Localized and Unresectable Pancreatic Cancer

Purpose: The use of chemoradiotherapy (CRT) for localized and unresectable pancreatic cancer has been disputed because of high probability of distant metastasis. Thus, we analyzed the effect of clinical parameters on tumor response, early distant metastasis within 3 months (DM{sup 3m}), and overall survival to identify an indicator for selecting patients who would benefit from CRT. Methods and Materials: This study retrospectively analyzed the data from 84 patients with localized and unresectable pancreatic cancer who underwent CRT between August 2002 and October 2009. Sex, age, tumor size, histological differentiation, N classification, pre- and post-treatment carbohydrate antigen (CA) 19-9 level, and CA 19-9 percent decrease were analyzed to identify risk factors associated with tumor response, DM{sup 3m}, and overall survival. Results: For all 84 patients, the median survival time was 12.5 months (range, 2-31.9 months), objective response (complete response or partial response) to CRT was observed in 28 patients (33.3%), and DM{sup 3m} occurred in 24 patients (28.6%). Multivariate analysis showed that pretreatment CA 19-9 level ({<=}400 vs. >400 U/ml) was significantly associated with tumor response (45.1% vs. 15.2%), DM{sup 3m} (19.6% vs. 42.4%), and median overall survival time (15.1 vs. 9.7 months) (p < 0.05 for all three parameters). Conclusion: For patients with localized and unresectable pancreatic cancer, pretreatment CA 19-9 level could be helpful in predicting tumor response, DM{sup 3m}, and overall survival and identifying patients who will benefit from CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Cancers From Modern Radiotherapy Techniques: Intensity-Modulated Radiotherapy Versus Proton Therapy

Purpose: To assess and compare secondary cancer risk resulting from intensity-modulated radiotherapy (IMRT) and proton therapy in patients with prostate and head-and-neck cancer. Methods and Materials: Intensity-modulated radiotherapy and proton therapy in the scattering mode were planned for 5 prostate caner patients and 5 head-and-neck cancer patients. The secondary doses during irradiation were measured using ion chamber and CR-39 detectors for IMRT and proton therapy, respectively. Organ-specific radiation-induced cancer risk was estimated by applying organ equivalent dose to dose distributions. Results: The average secondary doses of proton therapy for prostate cancer patients, measured 20-60cm from the isocenter, ranged from 0.4 mSv/Gy to 0.1 mSv/Gy. The average secondary doses of IMRT for prostate patients, however, ranged between 3 mSv/Gy and 1 mSv/Gy, approximately one order of magnitude higher than for proton therapy. Although the average secondary doses of IMRT were higher than those of proton therapy for head-and-neck cancers, these differences were not significant. Organ equivalent dose calculations showed that, for prostate cancer patients, the risk of secondary cancers in out-of-field organs, such as the stomach, lungs, and thyroid, was at least 5 times higher for IMRT than for proton therapy, whereas the difference was lower for head-and-neck cancer patients. Conclusions: Comparisons of organ-specific organ equivalent dose showed that the estimated secondary cancer risk using scattering mode in proton therapy is either significantly lower than the cases in IMRT treatment or, at least, does not exceed the risk induced by conventional IMRT treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of Movement-Induced Dose Reduction in Target Volume: A Comparison Between Photon and Proton Beam Treatment

We compared the main characteristics of movement-induced dose reduction during photon and proton beam treatment, based on an analysis of dose-volume histograms. To simulate target movement, a target contour was delineated in a scanned phantom and displaced by 3 to 20 mm. Although the dose reductions to the target in the 2 treatment systems were similar for transverse (perpendicular to beam direction) target motion, they were completely different for longitudinal (parallel to beam direction) target motion. While both modalities showed a relationship between the degree of target shift and the reduction in dose coverage, dose reduction showed a strong directional dependence in proton beam treatment. Clinical simulation of target movement for a prostate cancer patient showed that, although coverage and conformity indices for a 6-mm lateral movement of the prostate were reduced by 9% and 16%, respectively, for proton beam treatment, they were reduced by only 1% and 7%, respectively, for photon treatment. This difference was greater for a 15-mm target movement in the lateral direction, which lowered the coverage and conformity indices by 34% and 54%, respectively, for proton beam treatment, but changed little during photon treatment. In addition, we found that the equivalent uniform dose (EUD) and homogeneity index show similar characteristics during target movement. These results suggest that movement-induced dose reduction differs significantly between photon and proton beam treatment. Attention should be paid to the target margin in proton beam treatment due to the distinct characteristics of heavy ion beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of Lipiodol Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Hepatocellular Carcinoma

Purpose: To evaluate the influence of lipiodol on the proton beam range, which has not yet been determined. Methods and Materials: Two computed tomography (CT) data sets were obtained with a T25-flask containing lipiodol and water that was placed above a water phantom. The plan with the lipiodol CT images was performed, and then a verification plan was applied to the water CT images. The actual proton beam ranges in the lipiodol and water were measured under same conditions, and we compared the calculated proton beam range in the treatment planning system with measured values. Results: The calculated distal range in the treatment planning system was 12 cm in water, which was 3.87 cm longer than that in lipiodol (8.13 cm). In contrast, the measured distal range was 12 {+-} 0.01 cm in water, which was 0.21 {+-} 0.01 cm longer than that of lipiodol (11.78 {+-} 0.01 cm). A 3.65 {+-} 0.01-cm range shift was found in the calculated range compared with the measured range. For 10 hepatocellular carcinoma patients, the distal range in the verification plan with the corrected CT images in which the Hounsfield unit (HU) value of lipiodolized lesion was replaced with the average HU value of the surrounding tissue was 0.61 {+-} 0.26 cm (range, 0.26-0.99) longer than that in the plan with uncorrected CT images. Conclusions: It could be relevant for the purposes of range calculation of proton beams in the treatment planning system that the HU value of a lipiodolized lesion is replaced by the average HU value of the surrounding normal tiss0008.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computerized tomography-based quality assurance tool for proton range compensators

The authors have developed an automatic quality assurance method based on computerized tomography (CT) data for physically manufactured proton range compensators. Eight range compensators used for proton therapy at their institution were scanned using CT and their depth distributions were compared with data provided by a proton treatment planning system (TPS). The depth difference (DD), distance to agreement (DTA), and a composite analysis (CA) indicating regions that passed either of the tests were used for depth verification. When the tolerance limits were set at 3 mm for DD and 1 mm for DTA, the average percentages of points exceeding the acceptance criteria for DD, DTA, and CA for the eight compensators were 9.0%, 5.3% and 3.2%, respectively. In general, the percentages of points exceeding the acceptance criteria were much higher in DD than in DTA analysis and mismatch of depth was greater in regions with high depth gradients. This is considered to arise mainly because of systematic errors such as the physical size of the drill, slight bending or slipping of the drill bit near high gradient regions, the limit of CT resolution, and the uncertainty in CT number. When the tolerance limit of DTA was increased from 1 to 2 mm, the average percentage of points exceeding the acceptance criteria for DTA was reduced from 5.3% to 0.9%. Their results show that depth comparison of proton range compensators based on CT images can provide more systematic data than does the current method, in which a representative group of drill points is measured manually.

62 RADIOLOGY AND NUCLEAR MEDICINE↗