Search NASA⌕ Search

Engineering topics

Commisso, R J

Publications and source records attributed to Commisso, R J.

Ion diode performance on a positive polarity inductive voltage adder with layered magnetically insulated transmission line flow

A pinch-reflex ion diode is fielded on the pulsed-power machine Mercury (R. J. Allen, et al., 15th IEEE Intl. Pulsed Power Conf., Monterey, CA, 2005, p. 339), which has an inductive voltage adder (IVA) architecture and a magnetically insulated transmission line (MITL). Mercury is operated in positive polarity resulting in layered MITL flow as emitted electrons are born at a different potential in each of the adder cavities. The usual method for estimating the voltage by measuring the bound current in the cathode and anode of the MITL is not accurate with layered flow, and the interaction of the MITL flow with a pinched-beam ion diode load has not been studied previously. Other methods for determining the diode voltage are applied, ion diode performance is experimentally characterized and evaluated, and circuit and particle-in-cell (PIC) simulations are performed. Results indicate that the ion diode couples efficiently to the machine operating at a diode voltage of about 3.5 MV and a total current of about 325 kA, with an ion current of about 70 kA of which about 60 kA is proton current. It is also found that the layered flow impedance of the MITL is about half the vacuum impedance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of 12-cm-Diameter, Argon Gas-Puff Experiments and Analyses with >200-ns Implosion Times at 3- to 6-MA Peak Currents

This paper reviews the motivation for, results from, and analyses of 12-cm-diameter argon gas-puff experiments carried out over the last four years on three generators at 3.2- to 6.5-MA peak currents, all with implosion times {>=}200 ns. Using the argon K-shell yield as a metric of implosion quality, high-quality implosions are obtained for an appropriate initial radial mass distribution, i.e., a distribution that is peaked on axis. Higher compressed densities and smaller final radii are observed compared to shell-like initial mass distributions. Theory and data suggest that these distributions mitigate the magnetic Rayleigh-Taylor instability. An energy analysis shows that (1) significant electrical energy is directly coupled to the pinch during the K-shell radiation pulse and (2) conversion of radially-directed kinetic energy into thermal energy is not the dominant mechanism responsible for the pinch K-shell radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Properties of the Best Ar K-Shell Radiators: Two Decades of Data Analysis from Seven Z-Pinch Drivers

Z Pinches formed from Ar gas puffs have been investigated for more than two decades. Experiments have been performed on many generators; a frequent objective has been maximization of the yield in the K-shell lines. The increase in available current during that time, from 2 to 15 MA, has resulted in a remarkable enhancement in yield from a few kJ on PITHON to {approx}300 kJ on Sandia's Z generator. We have analyzed spectroscopic and other radiation data from seven Z-pinch drivers, some dating back to 1991, in an effort to determine what properties of the pinches correlate with high K-shell yield. The strongest correlation is with the amount of mass that is heated to K-shell emitting temperatures. Those temperatures, effective at emitting Ar K-shell x rays, exhibit a range of {approx}1 to 2.4 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved voltage measurements of Z-pinch radiation sources with a vacuum voltmeter

A vacuum-voltmeter (VVM) was fielded on the Saturn pulsed power generator during a series of argon gas-puff Z-pinch shots. Time-resolved voltage and separately measured load current are used to determine several dynamic properties as the load implodes, namely, the inductance, L(t), net energy coupled to the load, E{sub coupled}(t), and the load radius, r(t). The VVM is a two-stage voltage divider, designed to operate at voltages up to 2 MV. The VVM is presently being modified to operate at voltages up to 6 MV for eventual use on the Z generator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bremsstrahlung target optimization for reflex triodes

The anode (tantalum) foil thickness in a reflex triode was varied from 2.5 to 250 {mu}m to maximize the dose from bremsstrahlung produced by a 1 MV, 1 MA, 100 ns electron beam. Experiments and computer simulations show that the dose is maximized for a foil thickness of about 25 {mu}m, 1/18th of the electron range computed from the continuous slowing down approximation. For foils thicker than optimum, self-absorption in the foil attenuates 10-100 keV photons, reducing the dose. For foils thinner than optimum, the dose decreases as a result of electron migration to large radius. A simple formula that predicts the optimum thickness as a function of the beam current and voltage is derived that should be applicable to a large range of experimental parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗