DOE OSTI · 21120534
Bremsstrahlung target optimization for reflex triodes
Abstract
The anode (tantalum) foil thickness in a reflex triode was varied from 2.5 to 250 {mu}m to maximize the dose from bremsstrahlung produced by a 1 MV, 1 MA, 100 ns electron beam. Experiments and computer simulations show that the dose is maximized for a foil thickness of about 25 {mu}m, 1/18th of the electron range computed from the continuous slowing down approximation. For foils thicker than optimum, self-absorption in the foil attenuates 10-100 keV photons, reducing the dose. For foils thinner than optimum, the dose decreases as a result of electron migration to large radius. A simple formula that predicts the optimum thickness as a function of the beam current and voltage is derived that should be applicable to a large range of experimental parameters.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Swanekamp, S B, Weber, B V, Stephanakis, S J, Mosher, D, Commisso, R J. 2008-08-15. Bremsstrahlung target optimization for reflex triodes. https://doi.org/10.1063/1.2963090. https://searchnasa.com/record/osti%3A21120534/bremsstrahlung-target-optimization-for-reflex-triodes
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.