Search NASA⌕ Search

Engineering topics

Mosher, D

Publications and source records attributed to Mosher, D.

OPTIMIZATION OF INTERNAL HEAT EXCHANGERS FOR HYDROGEN STORAGE TANKS UTILIZING METAL HYDRIDES

Two detailed, unit-cell models, a transverse fin design and a longitudinal fin design, of a combined hydride bed and heat exchanger are developed in COMSOL{reg_sign} Multiphysics incorporating and accounting for heat transfer and reaction kinetic limitations. MatLab{reg_sign} scripts for autonomous model generation are developed and incorporated into (1) a grid-based and (2) a systematic optimization routine based on the Nelder-Mead downhill simplex method to determine the geometrical parameters that lead to the optimal structure for each fin design that maximizes the hydrogen stored within the hydride. The optimal designs for both the transverse and longitudinal fin designs point toward closely-spaced, small cooling fluid tubes. Under the hydrogen feed conditions studied (50 bar), a 25 times improvement or better in the hydrogen storage kinetics will be required to simultaneously meet the Department of Energy technical targets for gravimetric capacity and fill time. These models and methodology can be rapidly applied to other hydrogen storage materials, such as other metal hydrides or to cryoadsorbents, in future work.

08 HYDROGEN↗

K-line spectra from tungsten heated by an intense pulsed electron beam

The plasma-filled rod-pinch diode (PFRP) is an intense source of x-rays ideal for radiography of dense objects. In the PRFP megavoltage electrons from a pulsed discharge concentrate at the pointed end of a 1 mm diameter tapered tungsten rod. Ionization of this plasma might increase the energy of tungsten's K{alpha}{sub 1} fluorescence line, at 59.3182 keV, enough for the difference to be observed by a high-resolution Cauchois transmission crystal spectrograph. When the PFRP's intense hard bremsstrahlung is suppressed by the proper shielding, such an instrument gives excellent fluorescence spectra, albeit with as yet insufficient resolution to see any effect of tungsten's ionization. Higher resolution is possible with various straightforward upgrades that are feasible thanks to the radiation's high intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of 12-cm-Diameter, Argon Gas-Puff Experiments and Analyses with >200-ns Implosion Times at 3- to 6-MA Peak Currents

This paper reviews the motivation for, results from, and analyses of 12-cm-diameter argon gas-puff experiments carried out over the last four years on three generators at 3.2- to 6.5-MA peak currents, all with implosion times {>=}200 ns. Using the argon K-shell yield as a metric of implosion quality, high-quality implosions are obtained for an appropriate initial radial mass distribution, i.e., a distribution that is peaked on axis. Higher compressed densities and smaller final radii are observed compared to shell-like initial mass distributions. Theory and data suggest that these distributions mitigate the magnetic Rayleigh-Taylor instability. An energy analysis shows that (1) significant electrical energy is directly coupled to the pinch during the K-shell radiation pulse and (2) conversion of radially-directed kinetic energy into thermal energy is not the dominant mechanism responsible for the pinch K-shell radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Properties of the Best Ar K-Shell Radiators: Two Decades of Data Analysis from Seven Z-Pinch Drivers

Z Pinches formed from Ar gas puffs have been investigated for more than two decades. Experiments have been performed on many generators; a frequent objective has been maximization of the yield in the K-shell lines. The increase in available current during that time, from 2 to 15 MA, has resulted in a remarkable enhancement in yield from a few kJ on PITHON to {approx}300 kJ on Sandia's Z generator. We have analyzed spectroscopic and other radiation data from seven Z-pinch drivers, some dating back to 1991, in an effort to determine what properties of the pinches correlate with high K-shell yield. The strongest correlation is with the amount of mass that is heated to K-shell emitting temperatures. Those temperatures, effective at emitting Ar K-shell x rays, exhibit a range of {approx}1 to 2.4 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved voltage measurements of Z-pinch radiation sources with a vacuum voltmeter

A vacuum-voltmeter (VVM) was fielded on the Saturn pulsed power generator during a series of argon gas-puff Z-pinch shots. Time-resolved voltage and separately measured load current are used to determine several dynamic properties as the load implodes, namely, the inductance, L(t), net energy coupled to the load, E{sub coupled}(t), and the load radius, r(t). The VVM is a two-stage voltage divider, designed to operate at voltages up to 2 MV. The VVM is presently being modified to operate at voltages up to 6 MV for eventual use on the Z generator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bremsstrahlung target optimization for reflex triodes

The anode (tantalum) foil thickness in a reflex triode was varied from 2.5 to 250 {mu}m to maximize the dose from bremsstrahlung produced by a 1 MV, 1 MA, 100 ns electron beam. Experiments and computer simulations show that the dose is maximized for a foil thickness of about 25 {mu}m, 1/18th of the electron range computed from the continuous slowing down approximation. For foils thicker than optimum, self-absorption in the foil attenuates 10-100 keV photons, reducing the dose. For foils thinner than optimum, the dose decreases as a result of electron migration to large radius. A simple formula that predicts the optimum thickness as a function of the beam current and voltage is derived that should be applicable to a large range of experimental parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗