Search NASA⌕ Search

Engineering topics

Cooper, Matthew W.

Publications and source records attributed to Cooper, Matthew W..

At least 19 records

In the nuclear explosion monitoring context, what is an anomaly?

Abstract In the early years of nuclear explosion monitoring, experts used downwind detections with meaningful ratios of radioactive species to identify an explosion. Today’s reality is sparse networks of radionuclide monitoring stations looking for weak signals. Analysts need to discriminate between industrial background radioactivity and nuclear explosion signals, even using the detection of one isotope. Aerosol and xenon measurements potentially related to nuclear tests in 2006 and 2013 announced by the Democratic People’s Republic of Korea and from worldwide civilian background radioactivity are considered when defining radionuclide detection anomalies to objectively guide the use of limited analyst resources and reduce the possibility of not detecting nuclear explosions.

Miley, Harry S.↗

Watchmen 3.3.0 Release Notes

This document describes the changes to Watchmen. This includes improvements to stability, search features, display of more detailed sample information and user access via authentication.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.3.0 User Guide: Revision 9

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen v3.2.0 Release Notes

This document describes the changes to Watchmen. This includes improvements to stability, search features, display of more detailed sample information and user access via authentication.

97 MATHEMATICS AND COMPUTING↗

Watchmen v3.2.0 User Guide: Revision 8

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Method for calculating radon activity and radon rejection using a beta-gamma detector

Radon interferes with concentration measurements used by atmospheric radioxenon systems. We demonstrate a method to quantify the amount of radon that is present in the detectors, the impact of radon activity on the minimum-detectable-concentrations, and how to determine the needed radon rejection levels. An example calculation shows a radon rejection level of 10 5 is sufficient to limit impact on the detector sensitivity. We anticipate this method will give analysist a better understanding of radon present in their measurements and allow system designers to tailor their systems’ radon rejection better for its location.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Watchmen 3.1.0 System Administrator Guide

This document is a system administrator guide for the Watchmen tool. It describes how system administrator should install the application components and configure the host system.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.0.0 System Administrators Guide

This document is a system administrator guide for the Watchmen tool. It describes how system administrator should install the application components and configure the host system.

97 MATHEMATICS AND COMPUTING↗

Beta-Gamma Data Viewer v2.2.34 User's Manual

This document provides an overview, and procedures, for operating the beta-gamma data viewer for 7 regions of interest (7 ROI) data. The Beta-Gamma 7 ROI Data Viewer is a set of software tools that allow for viewing and analysis of IMS 2.0 Pulse Height Data (PHD) / Pulse Beta Gamma (PBG) files, state of health (SoH) files, and event log files. This is an upgrade from previous release of the tool that includes calibration tools.

97 MATHEMATICS AND COMPUTING↗

Watchmen v2.5.2 Release Notes

This document describes the changes to Watchmen. This includes improvements to stability and the importation of station data from non-standard #RASAData block to standard #ProcessSensor block.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for assaying a radioactive gas, and related scintillation cells

A radioactive gas assay system comprises a scintillation cell production assembly, a detector assembly, a computer assembly, and a scintillation cell destruction assembly. The scintillation cell production assembly is configured to produce a scintillation cell comprising a glass scintillator shell containing a volume of radioactive gas. The detector assembly is configured to receive the scintillation cell and to detect photons emitted thereby. The computer assembly is configured to receive data from the detector assembly to automatically calculate an absolute activity of the volume of radioactive gas of the scintillation cell and radiation detection efficiencies of the detector assembly. The scintillation cell destruction assembly is configured to receive the scintillation cell and to rupture the substantially non-porous glass scintillator shell to release the volume of radioactive gas. A method of assaying a radioactive gas, and a scintillation cell are also described.

Robinson, Troy A.↗

Host-Free Yellow-Green Organic Light-Emitting Diodes with External Quantum Efficiency over 20% Based on a Compound Exhibiting Thermally Activated Delayed Fluorescence

Thermally activated delayed fluorescent (TADF) materials are advantageous as emitters in organic light-emitting diodes (OLEDs) due to their ability to utilize all excited states formed by charge recombination for light emission, potentially leading to 100% internal quantum efficiency. As in conventional fluorescent or phosphorescent OLEDs, TADF emitters are commonly doped at a relatively low concentration in a host matrix. However, increasing evidence suggest that balanced ambipolar transport properties and small aggregation-induced fluorescence quenching allows TADF emitters to be used alone in so-called host-free OLEDs. Here, we report on host-free OLEDs in which the EMLs consist solely of a yellow-green-emitting TADF compound, 5,5'-(2,3,5,6-tetra(carbazol-9-yl)-1,4-phenylene)bis(2-(4-(tert-butyl)phenyl)-1,3,4-oxadiazole), TCZPBOX. Devices with this host-free EML yield a maximum external quantum efficiency (EQE) of 21%, current efficacy (CE) of 73 cd/A, and power efficacy (PE) of 79 lm/W at a luminance of 10 cd/m 2 . At a high luminance of 10,000 cd/m 2 , a high EQE of 13% is maintained. A maximum luminance of 120,000 cd/m2 is reached at an applied voltage of 9.8 V. When TCZPBOX was doped in the host of 2,6-di(carbazol-9-yl)-pyridine (PYD2) at 40 wt. %, the device yielded a maximum EQE of 28%, CE of 94 cd/A, and PE of 100 lm/W at 10 cd/m 2 .

36 MATERIALS SCIENCE↗

$\beta-\gamma$ Absolute Calibration (Rev. 1)

Identification of nuclear events rely on accurate measurement of radioxenon releases. Measurement of radioxenon relies on accurately knowing the detection efficiency for each isotope. Four xenon isotopes are of interest: 135 Xe, 133 Xe, 133 mXe, and 131 mXe. Each isotope has a unique signature; however, there is overlap between each signature. A series of ratio terms, called interference ratios, helps account for the challenges created by the overlap. The ratio and detection efficiency terms are all determined during the initial detector calibration. Additional spectra are needed for a complete calibration: the radon daughter 214 Pb/ 214 Bi, the detector background, and the 137 Cs quality control (QC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Shadowing in Beta-Gamma Coincidence Plots for Radioxenon

This document describes a study of the cause of shadowing observed in certain beta-gamma plots produced with beta-gamma coincidence detectors for detection of radioxenon. Beta-gamma detectors must possess adequate resolution to allow for the metastable isotopes 131m Xe and 133m Xe to be distinguished from each other and from 133 Xe. One effect that can minimize the ability to distinguish the metastables from 133 Xe is the shadowing effect, in which a band of high-energy signal is present in addition to the primary signal. A study was performed to determine the cause of the shadowing, and how to minimize the effect of the shadowing on an individual beta cell. Through this study, it is determined that the shadowing results from a difference in light transmission between the dome and end-cap portions of the beta cell. Consequently, it is not possible to remove the shadowing during the beta cell manufacturing process. The shadowing must be minimized by preferentially matching the light output from the end-cap and dome portion prior to the manufacturing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the Number and Substitution Pattern of Carbazole Donors on the Singlet and Triplet State Energies in a Series of Carbazole-Oxadiazole Derivatives Exhibiting Thermally Activated Delayed Fluorescence

Substitution of a varying number of 9H-carbazole donors onto 2-(pentafluorophenyl)-5-phenyl-1,3,4-oxadiazole yields a series of donor–acceptor compounds with similar electrochemical band gaps, but dissimilar optical properties. Each substitution of a carbazole onto the 2- and 4-positions results in a 150–200 meV stabilization of the first singlet excited state, evident in the fluorescent emission. Here, the first triplet excited state is less sensitive to these substitutions, leading to a reduced energy separation between the singlet and triplet states, ΔE ST , with increasing carbazole content. OLED devices made using the donor–acceptor compounds exhibiting the lowest ΔE ST were fabricated and exhibit sky blue emission with an external quantum efficiency of up to 24.4% at a luminance of 10 cd m –2 , and 9.2% at 1000 cd m –2 .

36 MATERIALS SCIENCE↗