Jemima Plate Characterization

The HEU Jemima plates have been utilized in numerous International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations. ICSBEP evaluations are a vital com ponent of nuclear data validation for applications across the nuclear community. In the past, different combinations of mass, caliper measurements, and drawing dimensions have been used to define the HEU Jemima plates in ICSBEP evaluations. Some of these combinations result in large density ranges (17 g/cm 3 to 19 g/cm 3 ) or unrealistic densities (greater than 19 g/cm 3 ). Additionally, oxidation of the plates has led to questioning the flatness of each plate, which can add additional gaps in experiment configurations. This work proposes a standardized method of defining the commonly used HEU Jemima plates across different experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How to Safely Build 100-plus Kilograms of Weapons-Grade Plutonium

The goal of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project was to reduce compensating errors by utilizing machine learning to both help determine which reactions contain compensating errors as well as optimizing an experiment which can be used to maximally reduce these errors. Compensating errors can adversely impact the predictive power of application simulations, and therefore it’s useful to further constrain nuclear data and reduce these errors. The EUCLID project included building two configurations at the National Criticality Experiments Research Center (NCERC). These two configurations had very different geometries (one was cube-like and one was slab-like). Previous works focus on selection of the target experiment(s), radiation transport capabilities developed in the project, the experiment optimization, and the performance of the experiments. This work will focus only on the safety aspects of performing this experiment, which utilized over 100 kg of weapons-grade plutonium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Data Sensitivity/Uncertainty Studies of Tantalum-Reflected Systems

Tantalum (Ta) is a refractory metal with high melting point and high corrosion resistance. This makes it useful as a mold material for plutonium casting operations. Unfortunately, there are few criticality benchmarks with high nuclear data sensitivities. Given that, it is desirable to design new experiments to provide additional validation data for nuclear criticality safety, which is the objective of the Thales project. Multiple application models were used to represent process conditions (either normal conditions or credible upset conditions) both at Los Alamos National Laboratory (LANL) and Savannah River Site (SRS). A total of 40 application models were obtained. Given this, it was useful to down-select the number of needed application models. This work documents the down-selection based on several nuclear data sensitivity/uncertainty metrics. In addition to showing the result of the specific down-selection used for the Thales project, this work discusses potential ways to represent a large number of application models with a smaller number of proposed experiment designs.

42 ENGINEERING↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

3-Helium↗

Empirical Bounding Analysis and User Recommendations for a Neutron Multiplicity Detector

Neutron multiplicity detectors are useful for a variety of applications including nuclear emergency response, nuclear nonproliferation, safeguards, and criticality safety. When measuring black-box problems (i.e., when the system being measured is completely unknown) with systems that have relatively low detection efficiency, expert analysis is frequently required to determine appropriate bounds for system parameters such as neutron multiplication and neutron leakage. This is because the detection efficiency can vary wildly, which also means that the resulting system parameters can have large variations. This work applies an empirical approach to provide bounds on system parameters (such as system multiplication, neutron leakage, and detector efficiency). The results of this bounding analysis are then used as inputs to provide recommendations to users regarding criticality safety. In addition to describing the method used, this work provides sample results from a measurement campaign performed at the National Criticality Experiments Research Center (NCERC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Criticality Experiments to Reduce Compensating Errors in Plutonium Nuclear Data

Compensating errors between nuclear data observables in a library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors in nuclear data. A new criticality experiment, described in this work, was designed with the specific target nuclear data of 239 Pu fission, inelastic scattering, elastic scattering, capture, nu-bar, and prompt fission neutron spectrum (PFNS). This work will focus on the design and execution of the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). The criticality experiment includes two different configurations with very different geometries: one is cube-like to minimize neutron leakage while the other is slab-like to maximize leakage. Having these two widely varying configurations allows the scattering sensitivities of 239 Pu to the neutron multiplication factor to be greatly changed while minimally impacting the other cross section sensitivities. Both configurations utilize the Pu ZPPR (Zero Power Physics Reactor) plates as fuel. The experiments were designed using a D-Optimality criteria, which is an optimization method minimizing the log-determinant of the adjusted nuclear data covariance for the target reactions. These experiments include not only inference of k eff , as done in all critical benchmark experiments, but several other responses as well, such as neutron multiplication measurements and reaction rate ratios. After analysis of the measured data is complete, adjustment of nuclear data will be performed to assess whether the new experimental data successfully reduced compensating errors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactivity Coefficient Measurements to Aid in Reducing Compensating Errors in Plutonium Nuclear Data

Compensating errors between several nuclear data observables in a nuclear data library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors between fast (0.1–5 MeV) 239Pu nuclear data for prompt fission neutron spectra (PFNS), average prompt fission neutron multiplicities, and neutron induced fission, capture, elastic, and inelastic cross sections. This work will focus on the design and execution of void reactivity coefficient measurements in the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). Two different base configurations were designed and measured, one with high neutron leakage, and one with low neutron leakage. Both were primarily made up of plutonium metal (Zero Power Physics Reactor plates) without interstitial moderators and reflected by half-inch aluminum. Design optimization showed that void reactivity coefficient measurements in three locations per configuration was most impactful to reduce nuclear data uncertainties due to the varying impacts from elastic and inelastic scattering, as well as fission and capture. The locations for measurements were chosen based on preliminary studies which balanced measurement uncertainty and measurement practicality. The measurements were also selected to have sensitivities maximally complementary to previous arrangements. Comparisons across nuclear data libraries highlight the potential impact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters

Accurately predicting the criticality of an experiment before interacting with the experimental components is very important for criticality safety. Radiation transport software can be utilized to calculate the effective neutron multiplication factor of a nuclear system. Because of the integral nature of the effective neutron multiplication factor, the value calculated contains various sources of nuclear-data induced uncertainty. The sensitivity analysis and data assimilation technique presented in this paper exhibit one possible method of identifying and reducing the effective neutron multiplication factor nuclear-data induced uncertainty. The results presented in this work show that it is possible to use relative sensitivity coefficients of the prompt neutron decay constant and the effective delayed neutron fraction to 239 Pu nuclear data to reduce nuclear-data induced uncertainties in the effective neutron multiplication factor. This work has been utilized by members of the Los Alamos National Laboratory project EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) for optimally designing a new experiment, which will be used to reduce compensating errors in 239 Pu nuclear data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva-IV Dosimetry Exercise 2022 (IER-538 CED4A Report)

This report presents the final results of IER 538, The International Nuclear Accident Dosimeter (NAD) Intercomparison Exercise with Godiva-IV. The purpose of the exercise, held in August of 2022, was to test participants’ NADs and dosimetry personnel to the dose estimation requirements established by ANSI/HPS-N13.3 Dosimetry for Criticality Accidents and DOE-STD-1098-2017, Radiological Control. Two prompt critical bursts of the Godiva critical assembly were used to simulate criticality accidents, and NADs from participating laboratories were placed at known locations around Godiva, mounted on either BOttle Manikin ABsorptions (BOMABs) phantoms (to simulate doses received by people) or plates (to simulate doses in free air). Similar exercises have been held in 2016 and 2018 using National Criticality Experiments Research Center’s (NCERC’s) Flattop and Godiva assemblies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters [Slides]

Sensitivity coefficients of prompt neutron decay constant (α) and effective delayed neutron fraction (β eff ) to Pu-239 nuclear data were calculated using a newly available tool (ACEtk). Uncertainty calculations showed the following trends: (1) The prompt neutron decay constant can be used to reduce nuclear data-induced uncertainty in Pu-239(n,f) and (2) the effective delayed neutron fraction can be used to effectively reduce nuclear data-induced uncertainty in Pu-239 total fission $\tilde{v}$. Sensitivity/uncertainty analysis can be used to determine optimal experiment/detector setup to identify compensating errors in nuclear data. Upcoming work includes investigating other nuclide-reaction pairs and response sensitivities, such as Δ$\rho$, neutron leakage spectra, and reaction rate measurements to constrain nuclear data of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-α measurements on a system consisting of weapons grade plutonium moderated by polyethylene

A critical experiment was performed on the Planet critical assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented. The neutron spectrum appears to be extremely thermal when compared to other thermal systems and the configuration will be able to validate thermal scattering law.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proposed Plutonium-Nickel Critical Experiment

The Los Alamos Critical Experiments Facility (LACEF) and subsequently its descendant, the National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site, have been performing critical experiments for over 75 years. The work done continues to build upon lessons learned from the past. It also builds upon knowledge gained from past experiments. The LACEF and NCERC experiments “provide nuclear criticality benchmark data for a wide variety of fissile and non-fissile materials in all neutron energy spectra systems”. In 2014, a subcritical benchmark with plutonium surrounded by nickel was issued in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Two years later, a new benchmark experiment was performed, commonly known as Subcritical Copper Reflected $\mathcal{a}$-Phase Plutonium SCR$\mathcal{a}$P. The uncertainties in the SCR$\mathcal{a}$P experiment were significantly reduced from the Pu-Ni experiment and the methods were refined. Additionally, a Pu-lead critical experiment was performed in 2017 which followed different methods and with different objectives. Now, an experiment is proposed that builds on both the subcritical nickel experiment and the critical lead experiment. The proposed experiment has interleaved nickel and plutonium, in a thermal arrangement. This particular experiment would support criticality safety at the Hanford Tank Farms, whose tanks contain a significant amount of nickel credited as a neutron absorber in the criticality safety evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic Measurements and Analyses for Lead Void Reactivity Worth in a Plutonium Core and Two Uranium Cores with Different Enrichments

To validate lead (Pb) nuclear cross sections, a series of integral experiments to measure lead void reactivity worth was conducted systematically in three fast neutron spectra with different fuel compositions on the Comet critical assembly of the National Criticality Experiments Research Center. Previous experiments in high-enriched uranium (HEU)/Pb and low-enriched uranium (LEU)/Pb systems had been performed in 2016 and 2017, respectively. A follow-on experiment in a plutonium (Pu)/Pb system has been completed. The Pu/Pb system was constructed using lead plates and weapons-grade Pu plates that had been used in the Zero Power Physics Reactor (ZPPR) of Argonne National Laboratory until the 1990s. Furthermore, the HEU/Pb system was reexamined on the Comet critical assembly with a newly installed device that can measure the compression of the stack, improving reproducibility. Using the lead void reactivity worth measured in these three cores with different fuel compositions, the latest nuclear data libraries, JENDL-4.0 and ENDF/B-VIII.0, were tested with the Monte Carlo calculation code MCNP® version 6.1. As a result, the calculations by ENDF/B-VIII.0 were confirmed to agree with lead void reactivity worth measured in all the cores. It was furthermore found that the calculations by JENDL-4.0 overestimate by more than 20% for the Pu/Pb core while being in good agreement for the HEU/Pb and LEU/Pb cores.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Primary Assessment Technologies FY2017 Milestone Report: NDSE Development Using DPF

A new diagnostic technique for a neutron-based measurement of dynamic subcritical experiments is currently under development. The technique, referred to as a Neutron Diagnosed Subcritical Experiment (NDSE), requires that a short intense burst of neutrons be directed into a subcritical fissile object and a precision measurement of the emitted fission gamma rays be made as a function of time. Recent advances in a dense plasma neutron source and gamma ray detectors have been integrated together at the Nevada National Security Site to provide a NDSE technique development and testing capability. The first set of NDSE demonstration experiments have now been completed using static objects constructed with large quantities of highly enriched uranium. The acquired data reveal the expected sensitivity to changes in neutronic properties of fissile objects and illustrate that the diagnostic approach is viable. As expected for any new measurement technique, many areas for improvement have been identified during static object testing and continued maturation of the diagnostic is planned before implementation on a dynamic subcritical experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252 Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗