Search NASA⌕ Search

Engineering topics

Cutler, T.

Publications and source records attributed to Cutler, T..

22 records · Page 2

Subcritical Benchmark of the BeRP Ball Reflected by Tungsten

In September 2012, eight subcritical configurations were measured with the clad a-phase plutonium sphere known as the Beryllium-Reflected Plutonium (BeRP) ball at the National Criticality Experiments Research Center (NCERC). The configurations had varying tungsten thicknesses including: 0 (bare), 0.5, 1.0, 1.5, 2.0, 2.5, 2.75, and 3.0 inches. Measurements were conducted to provide subcritical benchmark data. This work includes measured and simulated results from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP) evaluation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Criticality Eigenvalue Simulations for Subcritical Benchmark Evaluations

Subcritical multiplication experiments and simulations are important for a variety of applications including nonproliferation, safeguards, and criticality safety monitoring. Recently, subcritical experiments have been evaluated for inclusion in the International Criticality Safety Benchmark Evaluation Process (ICSBEP). In addition, new subcritical experiments have recently been designed. In these experiments, list-mode data (a list of each absorption in the neutron detector) is recorded and neutron noise analysis is used to determine the leakage multiplication (ML) of each configuration. One downside to the simulation of these types of experiments is that they are computationally expensive. This is because analog Monte Carlo with no variance reduction must be performed in order to maintain the time accuracy required in the measurement analysis. This work demonstrates that criticality eigenvalue simulations can be used to estimate sensitivities and uncertainties for three parameters: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), and leakage multiplication (M{sub L}). This will provide a useful aid both in the design and evaluation of new subcritical measurements. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation of uncertainties for subcritical benchmark measurements - 14387

Subcritical measurements are used for many applications including nonproliferation, treaty verification, in-situ monitoring for criticality, and reactor subcriticality monitoring. Most analysis methods involve correlated neutron detection, based upon the property that fission events can create multiple neutrons that are born at nearly the same time (on a scale of 10{sup -13} or 10{sup -14} seconds). Many different time-correlated methods have been used since the 1950's and are still widely utilized today. This particular work describes an uncertainty analysis of measured data using the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. The Feynman Variance-to-Mean method was introduced by Feynman et al. in 1956 and is based upon the differences between the detector count data and the data that would be expected from measurements taken from a Poissonian source. The Hage-Cifarelli formalism relates moments of the Feynman histograms to several parameters of a system: leakage multiplication (M{sub L}), spontaneous fission rate (F{sub S}), (α,n) neutron emission rate (S{sub α}), detector efficiency (ε), and the moments of the number of neutrons emitted per fission (ν). The first part of the uncertainty method described in this work will show how to determine uncertainties of the first (R{sub 1}) and second (R{sub 2}) reduced factorial moments of the Feynman histograms. The second part of the method will describe how to determine the uncertainties in the other parameters given uncertainties in the reduced factorial moments; in particular, this work will focus on determining the uncertainties in M{sub L} and F{sub S}. This work will utilize measured data from a recent benchmark evaluation with a 4.5 kg sphere of α-phase plutonium to validate the uncertainty analysis. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Joint neutron measurements on the flat-top HEU critical assembly machine - 14388

Flat-Top is a critical assembly with a spherical core (either ∼17 kg of HEU or ∼6 kg of δ-phase Pu) surrounded by a spherical 1000 kg natural uranium reflector. In 2013, joint LANL and CEA measurements were conducted to measure Flat-Top configurations with the HEU core using He-3 detector systems. Similar experiments were previously documented in which the Caliban and Godiva critical assemblies were measured. The core and reflector of Flat-Top have a glory hole in which nuclear material or non-nuclear material may be placed. Five configurations were measured and included subcritical configurations at various reactivity states as well as a configuration at delayed critical. The various reactivity states were achieved by varying the placement of the safety blocks and control rods (composed of natural uranium). A description of the assembly and the specific configurations measured will be presented. The subcritical and delayed critical measurements were analyzed using the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This analysis can be used to calculate the multiplication of each configuration, from which the multiplication factor and reactivity are determined. These results are compared to the reactivity states based upon control rod worth curves and MCNP simulations. For this work, a new MCNP model was made to accurately represent the measured configurations. The ICSBEP handbook contains a benchmark of Flat-Top but all models are very simple and do not have the required fidelity to accurately represent the measured configurations. This work also examines the number of neutrons emitted per fission for this assembly (which has a significant contribution of induced fissions in U-238 due to the large natural uranium reflector). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗