Search NASA⌕ Search

Engineering topics

Danielson, Jeremy

Publications and source records attributed to Danielson, Jeremy.

Ultraviolet digital holographic microscopy (DHM) of micron-scale particles from shocked Sn ejecta

A cloud of very fast, O (km/s), and very fine, O (µm), particles may be ejected when a strong shock impacts and possibly melts the free surface of a solid metal. To quantify these dynamics, this work develops an ultraviolet, long-working distance, two-pulse Digital Holographic Microscopy (DHM) configuration and is the first to replace film recording with digital sensors for this challenging application. A proposed multi-iteration DHM processing algorithm is demonstrated for automated measures of the sizes, velocities, and three-dimensional positions of non-spherical particles. Ejecta as small as 2 µm diameter are successfully tracked, while uncertainty simulations indicate that particle size distributions are accurately quantified for diameters ≥4 µm. These techniques are demonstrated on three explosively driven experiments. Measured ejecta size and velocity statistics are shown to be consistent with prior film-based recording, while also revealing spatial variations in velocities and 3D positions that have yet to be widely investigated. Having eliminated time-consuming analog film processing, the methodologies proposed here are expected to significantly accelerate future experimental investigation of ejecta physics.

47 OTHER INSTRUMENTATION↗

Ross Filter Diode Array Analysis for Red Sage

A Ross Filter Diode Array (RFDA) diagnostic was fielded on the Cygnus x-ray source during the final stages of the Red Sage campaign. This report briefly describes the motivation for the diagnostic, its construction and operating principles, and the raw data that it produces followed by an in-depth look at the procedures used to analyze this data. RFDA signals from eight Cygnus shots conducted after the conclusion of Nightshade C are analyzed and those results are discussed. Finally, recommendations are made to improve the diagnostic for future experiments.

42 ENGINEERING↗

High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface registration using a multi-beam optical probe and backscatter reflectometer

We introduce a technique for locating the position and orientation of an object surrounding a compound optical probe. The probe allows for simultaneous measurement of 150 points of laser velocimetry, and prior to a dynamic experiment it is important to know the initial position of the surface. Using an optical switch and a Luna OBR rangefinder, we measure the surface distance at hundreds of locations. These measurements are then combined with a dimensional inspection of the object and analysis routines to report the orientation and location of the inner surface relative to the probe. In addition, we present a technique to simultaneously measure the beam paths using a reference hemispherical surface and a number of distance measurements.

47 OTHER INSTRUMENTATION↗

Nightshade Prototype Experiments (Silverleaf)

The Red Sage campaign is a series of subcritical dynamic plutonium experiments designed to measure ejecta. Nightshade, the first experiments in Red Sage scheduled for fiscal year 2019, will measure the amount of ejecta emission into vacuum from a double-­shocked plutonium surface. To address the major technical risks in Nightshade, a Level 2 milestone was developed for fiscal year 2016. Silverleaf, a series of four experiments, was executed at the Los Alamos National Laboratory in July and August 2016 to demonstrate a prototype of the Nightshade package and to satisfy this Level 2 milestone. This report is documentation that Red Sage Level 2 milestone requirements were successfully met.

42 ENGINEERING↗

Silverleaf: An Experimental Series in Support of Nightshade

In this series, a prototype package was designed and fielded to address a major technical risk of Nightshade: A comprehensive suite of drives and diagnostics must fit within a small space. In addition, this series satisfies a milestone for the project.

42 ENGINEERING↗

Disentangling Radiographic Contributions

Presentation describes research program and goal to understand all large radiographic contributions for a given image and assess if quantitative predictions can be made once contributions are understood, with current focus understanding scintillator response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sagebrush boom box soft radiography results

Presentation describes series of shots done at Special Technologies Laboratory in Santa Barbara, CA, using a high-explosive load on tin as a confirmatory study to quantitatively compare diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Nevada System Characterization Methods and Potential Improvements

Presentation describes current system characterization methods and potential improvements, concluding that (a) full understanding of complete edge spread function is critical for accurate density reconstruction, (b) shot-to-shot reproducibility is critical, (c) optical scatter must be separated from radiation scatter, and (d) detailed system understanding coupled with flexible detector geometry pays dividends in ability to optimize for any given experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗