Search NASA⌕ Search

Engineering topics

Essig, Rouven

Publications and source records attributed to Essig, Rouven.

At least 19 records

Charge-trap analysis in a SENSEI skipper-CCD: Understanding low-energy backgrounds in rare-event searches

Skipper charge-coupled devices (CCDs) are ultralow-threshold detectors capable of detecting energy deposits in silicon at the electronvolt scale. Skipper CCDs are increasingly used in rare-event searches, including experiments such as SENSEI, DAMIC-M, Oscura, and CONNIE, where one of the major challenges is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we use the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly, but more work is needed to assess the impact of the traps that cannot be characterized.

Brusco, Agustin↗

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of (1.39±0.11)×10^{-5} e^{-}/pix/day, corresponding to (39.8±3.1) e^{-}/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the wavelength range between near-infrared and ultraviolet. We use these data to obtain a 90% confidence level upper bound of 1.53×10^{-5} e^{-}/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

dark matter↗

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics↗

Search by the SENSEI Experiment for Millicharged Particles Produced in the NuMI Beam

Millicharged particles appear in several extensions of the standard model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultrarelativistic millicharged particles produced in collisions of protons in the NuMI beam with a fixed graphite target. The absence of any ionization events with 3 to 6 electrons in the SENSEI data allow us to place world-leading constraints on millicharged particles for masses between 30 to 380 MeV. This work also demonstrates the potential of utilizing low-threshold detectors to investigate new particles in beam-dump experiments, and motivates a future experiment designed specifically for this purpose. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-sided charge-coupled devices

Existing charge-coupled devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. Here, we propose an imager, the dual-sided CCD, which collects and measures both charge carriers on opposite sides of the device via a dual-buried channel architecture. We show that this dual detection strategy provides exceptional dark-count rejection and enhanced timing capabilities. These advancements have wide-ranging implications for dark-matter searches, near-infrared/optical spectroscopy, and time-domain x-ray astrophysics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar reflection of dark matter with dark-photon mediators

Abstract We consider the scattering of low-mass halo dark-matter particles in the hot plasma of the Sun, focusing on dark matter that interact with ordinary matter through a dark-photon mediator. The resulting “solar-reflected” dark matter (SRDM) component contains high-velocity particles, which significantly extend the sensitivity of terrestrial direct-detection experiments to sub-MeV dark-matter masses. We use a detailed Monte Carlo simulation to model the propagation and scattering of dark-matter particles in the Sun, including thermal effects, with special emphasis on ultralight dark-photon mediators. We study the properties of the SRDM flux, obtain exclusion limits from various direct-detection experiments, and provide projections for future experiments, focusing especially on those with silicon and xenon targets. We find that proposed future experiments with xenon and silicon targets can probe the entire “freeze-in benchmark”, in which dark matter is coupled to an ultralight dark photon, including dark-matter masses as low as 𝒪(keV). Our simulations and SRDM fluxes are publicly available.

Astronomy & Astrophysics↗

Low-energy Compton scattering in materials

Low-energy Compton scattering is an important background for sub-GeV dark matter direct-detection and other experiments. Current Compton scattering calculations typically rely on assumptions that are not valid in the low-energy region of interest, beneath ∼ 50 eV . Here we relate the low-energy Compton scattering differential cross section to the dielectric response of the material. Our new approach can be used for a wide range of materials and includes all-electron, band-structure, and collective effects, which can be particularly relevant at low energies. We demonstrate the strength of our approach in several solid-state systems, in particular, Si, Ge, GaAs, and SiC, which are relevant for current and proposed experiments searching for dark matter, neutrinos, and millicharged particles. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Fully ab-initio all-electron calculation of dark matter-electron scattering in crystals with evaluation of systematic uncertainties

We calculate target-material responses for dark matter–electron scattering at the all-electron level using atom-centered Gaussian basis sets. The all-electron effects enhance the material response at high momentum transfers from dark matter to electrons, q ≳ O ( 10 α m e ) , compared to calculations using conventional plane wave methods, including those used in ; this enhances the expected event rates at energy transfers E ≳ 10 eV , especially when scattering through heavy mediators. We carefully test a range of systematic uncertainties in the theory calculation, including those arising from the choice of basis set, exchange-correlation functional, number of unit cells in the Bloch sum, k -mesh, and neglect of scatters with very high momentum transfers. We provide state-of-the-art crystal form factors, focusing on silicon and germanium. Our code and results are made publicly available as a new tool, called (“”). Published by the American Physical Society 2024

Dreyer, Cyrus E.↗

Doped semiconductor devices for sub-MeV dark matter detection

Dopant atoms in semiconductors can be ionized with ∼ 10 meV energy depositions, allowing for the design of low-threshold detectors. We propose using doped semiconductor targets to search for sub-MeV dark matter scattering or sub-eV dark matter absorption on electrons. Currently unconstrained cross sections could be tested with a 1 g-day exposure in a doped detector with backgrounds at the level of existing pure semiconductor detectors, but improvements would be needed to probe the freeze-in target. We discuss the corresponding technological requirements and lay out a possible detector design. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

The DarkNESS mission: probing dark matter with a Skipper-CCD satellite observatory

The invention of Skipper-CCDs with sub-electron noise has paved the way for groundbreaking low-threshold dark matter (DM) experiments, such as SENSEI and DAMIC. Conventionally, these experiments are deployed underground to mitigate cosmogenic backgrounds; however, some DM signatures are inaccessible to underground experiments due to attenuation in the Earth’s atmosphere and crust. The DarkNESS mission will deploy an array of Skipper-CCDs on a 6U CubeSat in Low Earth Orbit (LEO) to search for electron recoils from strongly-interacting sub-GeV DM as well as X-ray line signatures from sterile neutrino decay. Using a series of observations from LEO, the DarkNESS mission will set competitive upper limits on the DM-electron scattering cross section and help resolve the experimental conundrum associated with the purported observation of a 3.5 keV X-ray line, potentially produced from sterile neutrino decay. This work will describe the DarkNESS instrument, the technical challenges in operating Skipper-CCDs in the space environment, the scientific objectives of the DarkNESS mission, and the DM parameter space that DarkNESS will probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab

Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the ~MeV mass range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy radiative backgrounds in CCD-based dark-matter detectors

The reach of sub-GeV dark-matter detectors is at present severely affected by low-energy events from various origins. We present the theoretical methods to compute the single- and few-electron events that arise from secondary radiation emitted by high-energy particles as they pass through detector materials and perform a detailed simulation to quantify them at (Skipper) CCD-based experiments, focusing on the SENSEI data collected at Fermilab near the MINOS cavern. The simulations account for the generation of secondaries from Cherenkov and luminescent recombination radiation; photo-absorption in the bulk, backside layer, pitch adapter, and epoxy; the photon reflection and refraction at interfaces; thin-film interference; the roughness of the interfaces; the dynamics of charges produced in the highly doped CCD-backside-layers; and the partial charge collection on the CCD backside. We consider several systematic uncertainties, notably those stemming from the backside modeling, which we estimate with a “fiducial” and an “extreme” charge-diffusion model, with the former model being preferred due to better agreement with partial-charge collection data. We find that Cherenkov photons constitute about 30% of the observed single-electron events for both diffusion models; radiative recombination contributes negligibly to the event rate for the fiducial model, although it can dominate over Cherenkov for the extreme model. We also estimate the fraction of 2-electron events that arise from 1-electron event coincidences in the same pixel, finding that the entire 2-electron rate can be explained by coincidences of radiative events and spurious charge. Accounting for both radiative and non-radiative backgrounds, we project the sensitivity of future Skipper-CCD-based experiments to different dark-matter models. For light-mediator models with dark-matter masses of 1, 5, and 10 MeV, we find that future experiments with 10-kg-year exposures and successful background mitigation could have a sensitivity that is larger by 9, 3, and 2 orders of magnitude, respectively, when compared to an experiment without background improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Migdal effect in semiconductors for dark matter detection

The Migdal effect has received much attention from the dark matter direct detection community, in particular due to its power in setting leading limits on sub-GeV particle dark matter. However, it is crucial to obtain experimental confirmation of the Migdal effect through nuclear scattering using Standard Model probes. In this work, we extend existing calculations of the Migdal effect to the case of neutron-nucleus scattering, with a particular focus on neutron scattering angle distributions in silicon. We identify kinematic regimes wherein the assumptions present in current calculations of the Migdal effect hold for neutron scattering and demonstrate that these include viable neutron calibration schemes. We then apply this framework to propose an experimental strategy to measure the Migdal effect in cryogenic silicon detectors using an upgrade to the NEXUS facility at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Migdal effect in semiconductors for dark matter with masses below ~ 100 MeV

Dark matter scattering off a nucleus has a small probability of inducing an observable ionization through the inelastic excitation of an electron, called the Migdal effect. We use an effective field theory to extend the computation of the Migdal effect in semiconductors to regions of small momentum transfer to the nucleus, where the final state of the nucleus is no longer well described by a plane wave. Our analytical result can be fully quantified by the measurable dynamic structure factor of the semiconductor, which accounts for the vibrational degrees of freedom (phonons) in a crystal. We show that, due to the sum rules obeyed by the structure factor, the inclusive Migdal rate and the shape of the electron recoil spectrum is well captured by approximating the nuclei in the crystal as free ions; however, the exclusive differential rate with respect to energy depositions to the crystal depends on the phonon dynamics encoded in the dynamic structure function of the specific material. Our results now allow the Migdal effect in semiconductors to be evaluated even for the lightest dark matter candidates (m χ ≳ 1 MeV) that can kinematically excite electrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗

Report of the Topical Group on Particle Dark Matter for Snowmass 2021

This report summarizes the findings of the CF1 Topical Subgroup to Snowmass 2021, which was focused on particle dark matter. One of the most important scientific goals of the next decade is to reveal the nature of dark matter (DM). To accomplish this goal, we must delve deep, to cover high priority targets including weakly-interacting massive particles (WIMPs), and search wide, to explore as much motivated DM parameter space as possible. A diverse, continuous portfolio of experiments at large, medium, and small scales that includes both direct and indirect detection techniques maximizes the probability of discovering particle DM. Detailed calibrations and modeling of signal and background processes are required to make a convincing discovery. In the event that a candidate particle is found through different means, for example at a particle collider, the program described in this report is also essential to show that it is consistent with the actual cosmological DM. The US has a leading role in both direct and indirect detection dark matter experiments -- to maintain this leading role, it is imperative to continue funding major experiments and support a robust R&D program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗