Precursor Analysis Report: Doppelpaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019

The DoppelPaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019 Precursor Analysis Report leverages publicly available information about the PEMEX cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. The 2019 DoppelPaymer ransomware attack on PEMEX, Mexico’s nationalized petroleum corporation, highlights a unique threat that ransomware and cybercriminal extortion poses to Operational Technology (OT) environments in critical infrastructure. The incident began with an employee downloading commodity malware that allowed adversaries to gain initial access to PEMEX’s enterprise environment. After conducting privilege escalation, tool ingress, and data exfiltration, the adversaries deployed DoppelPaymer ransomware throughout the PEMEX enterprise environment, resulting in the company having to take dozens of systems offline for at least several days. Although PEMEX stated that their operations were not affected, the data exfiltrated from PEMEX was made available for download on DoppelPaymer’s leak site, as well as on other illicit criminal forums. This stolen data included not only company information, but also sensitive OT-specific configuration data. This incident showcases how cybercriminal exfiltration and posting of sensitive OT architecture documentation can pose security concerns for the targeted organization for years due to the long lifespan of OT assets and architectures. Researchers and analysts identified 18 unique techniques utilized during the attack with a total of 190 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the DoppelPaymer ransomware attack were precursors to the triggering event. Analysis identified 163 observables associated with these precursor techniques, 34 of which were assessed to have an increased likelihood of being perceived in the 60 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: Remote Access Attack on Oldsmar Water Treatment Facility 2021

The Remote Access Attack on Oldsmar Water Treatment Facility 2021 Precursor Analysis Report leverages publicly available information about the Oldsmar cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 5 February 2021, an adversary gained unauthorized remote access to Bruce T. Haddock Water Treatment Plant in Oldsmar, Florida, which provides treated water to 15,000 customers. The adversary accessed the facility’s Supervisory Control and Data Acquisition (SCADA) workstation and human machine interface (HMI) to change the chemical concentration of sodium hydroxide, commonly referred to as lye and used to regulate acidity levels, from 100 parts per million (PPM) to 11,100 PPM. The chemical was raised to lethal levels that if ingested could lead to serious soft tissue damage, burns, or even death. The facility, however, had redundancies and alarms in place to alert personnel of dangerous chemical levels, and facility officials stated it would have taken 24 to 36 hours for the chemical changes to affect the water supply. Researchers and analysts identified six unique techniques utilized during the attack with a total of 23 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Four of the identified techniques used during the Oldsmar cyber attack were precursors to the triggering event. Analysis identified 21 observables associated with these precursor techniques, 20 of which were assessed to have an increased likelihood of being perceived in the minutes preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Micro Baselines for Operational Technology Environments

Critical infrastructure stakeholders need to baseline their networks to understand expected communications. Top-down approaches to baselining rely on observables that are generally available but lack properties upon which traditional statistical tools depend. We propose to construct micro-baselines: signatures within operational networks based on observables associated with specific events. Such observables are informed by precursor analysis reports of historical cyber attacks on operational environments developed by Cybersecurity for Operational Technology Environments (CyOTE). Baseline measurements depend upon context beyond the cyber domain. An energy plant's baseline running in the summer may statistically differ from a similar facility in a colder region. Domain knowledge must be integrated to apply general micro-baselining algorithms to a facility-specific context. Therefore, we propose to explore the feasibility of transferring micro baselining algorithms across different facilities. Facilities that implement the same processes in different geographic locations will be compared relative to observable measurements used in micro-baselining for comparable events. One evaluation approach would condition or augment dynamic observables measured within a facility network testbed with additional observables derived from geographic context or infrastructure dependencies such as those provided by the All-Hazards Analysis tool.

97 MATHEMATICS AND COMPUTING↗