Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION

Validation of predictive performance models for supersonic gas-jet nozzles at the Laboratory for Laser Energetics

We present results characterizing the neutral-density distributions produced by the supersonic nozzles used in experiments on the OMEGA-60 and OMEGA-EP laser systems at the University of Rochester’s Laboratory for Laser Energetics (LLE). Axisymmetric Fluent® simulations using LLE nozzle specifications capture the viscous effects, gas expansion, and shock waves that complicate flow predictions for offsets above the nozzle exit. Here, these simulations show good agreement with neutral-density measurements obtained using a four-wave shearing interferometer. An analytical form is given for the plateau length. Fits to simulation data for boundary layer thickness, mean plateau density, and density ramps are given as functions of nozzle offset and nozzle backing pressure for a number of nozzles and gases.

47 OTHER INSTRUMENTATION