DOE OSTI · 2440768
Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources
Abstract
With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Bouffetier, V., Pérez-Callejo, G., Stutman, D., Stoeckl, C., Begishev, I. A., Theobald, W., Filkins, T., Mileham, C., Ceurvorst, L., Klein, S. R., Goudal, T., Casner, A., Valdivia, M. P.. 2024-09-10. Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources. https://doi.org/10.1364/oe.516695