Search NASA⌕ Search

Engineering topics

Mileham, C.

Publications and source records attributed to Mileham, C..

At least 19 records

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Final amplifier of an ultra-intense all-OPCPA system with 13-J output signal energy and 41% pump-to-signal conversion efficiency

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 × 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. The seed beam (180-nm bandwidth, 110 mJ) was provided by the preceding OPCPA stages. A maximum pump-to-signal conversion efficiency of 41% and signal energy up to 13 J were achieved with a 52-mm-long DKDP crystal due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape.

47 OTHER INSTRUMENTATION↗

Generation of a controllable TNSA deuteron beam using deuterated metal targets

This study investigated the feasibility of using deuterated titanium targets for the generation of a target normal sheath acceleration (TNSA) deuteron beam. Commercial 25-μm-thick titanium foil was cut into 500 x 500-μm 2 squares and subsequently deuterated using different approaches. The spectra and total yields of all emitted ions were measured using a Thomson parabola ion spectrometer. It was found that a 24-h exposure to 1 atm of D 2 gas at 400°C is the most-efficient deuteration method, producing yields in the mid-10 11 deuterons per shot. The deuteron energy spectra changed from an exponential shape at low ion yields to exponentially modified Gaussians at higher yields. Simulations suggest that this effect is due to increased Coulomb interactions between the ions, which suppress the low energies. Separate campaigns will utilize the presented approach to produce a TNSA triton beam. Furthermore, two such targets will be used in a pitcher/catcher configuration to study the tritium–tritium reaction T(t, 2n)α.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of the pump beam profile and wavefront on the amplified signal wavefront in optical parametric amplifiers

We present a theoretical and experimental analysis of the signal phase introduced by the pump-beam wavefront and spatial profile during optical parametric amplification (OPA) process. The theory predicts the appearance of an additional wavefront in the amplified signal beam that is proportional to the spatial derivative of the pump-beam wavefront. The effect of the pump-beam profile on the signal-beam wavefront is also investigated. Our experiments tested these theoretical predictions by comparing the wavefront of the signal beam before and after amplification in a multi-joule broadband OPA. The measured signal wavefront was shown to have the expected dependence on the pump-beam profile and wavefront. These results can be considered when designing petawatt-scale ultrabroadband optical parametric chirped-pulse–amplification systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Causes of fuel–ablator mix inferred from modeling of monochromatic time-gated radiography of OMEGA cryogenic implosions

Here, we present evidence, in the context of OMEGA cryogenic target implosions, that laser imprint, known to be capable of degrading laser-direct-drive target performance, plays a major role in generating fuel–ablator mix. OMEGA cryogenic target implosions show a performance boundary correlated with acceleration-phase shell stability; for sufficiently low adiabats (where the adiabat is the ratio of the pressure to the Fermi pressure) and high in-flight aspect ratios (IFAR's), the neutron-weighted shell areal density and neutron yield relative to the clean simulated values sharply decline. Direct evidence of Rayleigh–Taylor fuel–ablator mixing was previously obtained using a Si Heα backlighter driven by an ~20-ps short pulse generated by OMEGA EP. The shadow cast by the shell shortly prior to stagnation, as diagnosed using backlit radiographs, shows a softening near the limb, which is evidence of an ablator–fuel mix region for a low-adiabat implosion (α ~ 1.9, IFAR = 14) but not for a moderate adiabat implosion (α ~ 2.5, IFAR = 10). We find good agreement between experimental and synthetic radiographs in simulations that model laser imprint and account for uncertainty in the initial ablator thickness. Furthermore, we further explore the role of other mechanisms such as classical instability growth at the fuel–ablator interface, species concentration diffusion, and long-wavelength drive and target asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced laser development and plasma-physics studies on the multiterawatt laser

The Multi-Terawatt (MTW) laser, built initially as the prototype front-end for a petawatt laser system, is a 1053-nm hybrid system with gain from optical parametric chirped-pulse amplification (OPCPA) and Nd:glass. Here, compressors and target chambers were added, making MTW a complete laser facility (output energy up to 120 J, pulse duration from 20 fs to 2.8 ns) for studying high-energy-density physics and developing short-pulse laser technologies and target diagnostics. Further extensions of the laser support ultrahigh-intensity laser development of an all-OPCPA system and a Raman plasma amplifier. A short summary of the variety of scientific experiments conducted on MTW is also presented.

47 OTHER INSTRUMENTATION↗

MTW-OPAL: a technology development platform for ultra-intense optical parametric chirped-pulse amplification systems

Optical parametric chirped-pulse amplification implemented using multikilojoule Nd:glass pump lasers is a promising approach for producing ultra-intense pulses (>10 23 W/cm 2 ). We report on the MTW-OPAL Laser System, an optical parametric amplifier line (OPAL) pumped by the Nd:doped portion of the multi-terawatt (MTW) laser. This midscale prototype was designed to produce 0.5-PW pulses with technologies scalable to tens of petawatts. Technology choices made for MTW-OPAL were guided by the longer-term goal of two full-scale OPALs pumped by the OMEGA EP to produce 2 × 25-PW beams that would be co-located with kilojoule–nanosecond ultraviolet beams. Several MTW-OPAL campaigns that have been completed since “first light” in March 2020 show that the laser design is fundamentally sound, and optimization continues as we prepare for “first-focus” campaigns later this year.

42 ENGINEERING↗

Improved imaging using Mn He- α x rays at OMEGA EP

In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×. The system is designed to use a crystal along the crystal plane that satisfies the Bragg condition for the x ray of interest. The thin crystal is then bent into a spherical geometry and attached to a glass backing substrate to hold it in the diagnostic, and the x rays are imaged onto a charge coupled device. We report on data acquired with the new Los Alamos National Laboratory supplied spherical quartz crystal to image the Mn He-α 6.15 keV line emission.

Fiedler Kawaguchi, C. (ORCID:0000000175522370)↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Optimization of a short-pulse-driven Si He-α soft x-ray backlighter

High backlighter brightness is important to maximize the number of detected photons in radiography experiments and to minimize the background while backlighting high-energy density plasmas with strong self-emission. Here, several different configurations were tested to improve the brightness of the Si He-α x-ray line emission at a photon energy of 1865 eV from high-energy (>1 kJ), short-pulse (~20-ps), laser-driven backlighter targets. The emission from low-density SiO 2 foam targets, the effects of a laser prepulse, and Si targets with a CH “shield” that form a small cavity were compared to solid-density, flat Si targets. The CH “shield” targets showed the best performance with a >5× improvement in time integrated emission and an x-ray pulse duration of ~25 ps with no measurable spectral shift of the Si He-α emission line. A conversion efficiency from laser light into Si He-α photons of the order of 1 × 10 –5 was inferred from the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of laser-driven magnetic fields with a continuous wave Faraday rotation diagnostic

Magnetic fields driven by a laser in coil targets were studied for laser energies of ~25 J and two pulse durations of 2.8 ns and 70 ps. Axial magnetic fields in the coils were measured by continuous wave Faraday rotation diagnostics. The diagnostics indicated magnetic fields of 6–14 T in the coil and currents of 10–20 kA. Magnetic fields were compared for similar laser targets, focusing conditions, and laser energies. A 30-times increase in the intensity of the laser beam by reducing the pulse duration resulted in an increase in the magnetic field and current by a factor of 2. The relaxation time of the magnetic pulse was on the sub-microsecond scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Relativistic-electron-driven magnetic reconnection in the laboratory

Magnetic reconnection is a fundamental process occurring in many plasma systems. Magnetic field lines break and reconfigure in to a lower energy state, converting released magnetic field energy into plasma kinetic energy. Around some of the universe’s most energetic objects, such as gamma ray burst or active galactic nuclei, where the magnetic field energy exceeds the plasma rest mass energy, the most extreme magnetic reconnection in the relativistic regime is theorized. The pre- sented experiments and three-dimensional particle-in-cell modeling recreate in the laboratory the scaled plasma conditions necessary to access the relativistic electron regime and therefore approach conditions around these distant, inaccessible objects. High-power, ultrashort laser pulses focused to high-intensity (I > 2.5 × 1018 Wcm-2) on solid targets produces relativistic temperature electrons within the focal volume. The hot electrons are largely confined to the target surface and form a ra- dial surface current that generates a huge, expanding azimuthal magnetic field. Focusing two laser pulses in close proximity on the target surface leads to oppositely directed magnetic fields being driven together. The fast electron motion due to the magnetic reconnection is inferred using an ex- perimental x-ray imaging technique. The x-ray images enable the measurement of the reconnection layer dimensions and temporal duration. The reconnection rates implied from the aspect ratio of the reconnection layer, δ/L ≈ 0.3, was found to be consistent over a range of experimental pulse durations (40 fs–20 ps) and agreed with the modeling. Further experimental evidence for magnetic reconnection is the formation of a nonthermal electron population shown by the modeling to be accelerated in the reconnection layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of shaped Bragg crystal assemblies for narrowband x-ray imaging

X-ray imaging using shaped crystals in Bragg reflection is a powerful technique used in high-energy-density physics experiments. The characterization of these crystal assemblies with conventional x-ray sources is very difficult because of the required angular resolution of the order of ~10 μrad and the narrow bandwidth of the crystal. The 10-J, 1-ps Multi-Terawatt (MTW) laser at the Laboratory for Laser Energetics was used to characterize a set of Bragg crystal assemblies. The small spot size (of the order of 5 μm) and the high power (>10 18 W/cm 2 ) of this laser make it possible to measure the spatial resolution at the intended photon energy. A set of six crystals from two different vendors was checked on MTW, showing an unexpectedly large variation in spatial resolution of up to a factor of 4.

47 OTHER INSTRUMENTATION↗