Search NASA⌕ Search

Engineering topics

Frank, D. J.

Publications and source records attributed to Frank, D. J..

Development of a motorized cryovalve for the control of superfluid liquid helium

Recent advances in the technology of infrared detectors have made possible a wide range of scientific measurements and investigations. One of the requirements for the use of sensitive IR detectors is that the entire instrument be cooled to temperatures approaching absolute zero. The cryogenic cooling system for these instruments is commonly designed as a large dewar containing liquid helium which completely surrounds the apparatus. Thus, there is a need for a remotely controlled, motorized cryovalve that is simple, reliable, and compact and can operate over extended periods of time in cryo-vac conditions. The design, development, and test of a motorized cryovalve with application to a variety of cryogenic systems currently under development is described.

Lorell, K. R.↗

Integrated fountain effect pump device for fluid management at low gravity

A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.

Yuan, S. W. K.↗

Enclosed capillary device for low gravity management of He II

To transfer He II in space, a large tank must be drained at low gravity. This paper describes and analyzes an enclosed gallery device designed for collecting and delivering He II to a pump. The device allows most of the liquid to move about in the tank while it maintains a liquid flow to the pump. Only the liquid in the screen-covered gallery channels and in the upper and lower receivers is contained. The device operates by providing surface tension dominated liquid paths from all locations within the tank to the lower receiver, which houses the pump. Since the fluid pressure in the channels may be below the saturated vapor pressure, an analysis of He II cavitation is performed to determine if cavitation will occur. The effect of heat dissipation from the pump is examined to determine if it may result in nucleation of boiling. It is concluded that this enclosed device can meet the requirements for transfer of He II under the predicted adverse accelerations that will be encountered on-orbit.

Frank, D. J.↗

Study of helium transfer technology for STICCR: Fluid management

The Space Infrared Telescope Facility (SIRTF) is a long life cryogenically cooled space based telescope for infrared astronomy from 2 to 700 microns currently under study and planned for launch in the mid 90's. SIRTF will operate as a multi-user facility, initially carrying 3 instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and is currently baselined to be 2 years. Candidates are reviewed for a liquid management device to be used in the resupply of liquid helium, and for the selection of an appropriate candidate.

Frank, D. J.↗

Cryogenic fluid management for low-g transfer

An account is given of design and operations criteria pertaining to low-g environment systems for the collection and delivery of liquid cryogens to a supply tank drain inlet in orbit. Analyses must assess the draining efficiencies of such devices, because the minimization of supply tank residual contents is of the essence. Settling accelerations, passive expulsion, and positive expulsion methods of fluid control have all been successfully demonstrated in orbit. Attention is given to the unique advantages and disadvantages of each method in view of different sets of requirements.

Frank, D. J.↗