NASA NTRS · 19890053941
Integrated fountain effect pump device for fluid management at low gravity
Abstract
A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.
Keep this discovery
Explore connections, maps & timelines
Yuan, S. W. K., Frank, D. J.. 1988-02-01. Integrated fountain effect pump device for fluid management at low gravity. https://ntrs.nasa.gov/citations/19890053941
Cite the original work for its findings. Save a collection to share your selection of sources.