Search NASA⌕ Search

Engineering topics

Fujimoto, Kiyo T.

Publications and source records attributed to Fujimoto, Kiyo T..

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Enabling Success: Enhancing Accessibility in Professional Societies and Programs for Disabled Individuals

For disabled and chronically ill individuals, “extracurriculars” – or pursuit of activities that are additional or adjacent to job success beyond our position descriptions – can sometimes feel out of reach. Here, we encourage leadership of all organizations and institutions to fully engage with disabled individuals to understand some of the ways in which accommodations may fall short, and how we can overcome the issue of accessibility and its impacts on employee achievement and career trajectories.

99 GENERAL AND MISCELLANEOUS↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Quality Control Methods for Robust and Reliable Sensor Design

The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.

36 MATERIALS SCIENCE↗

Bi-metallic Nanoparticle Synthesis for Advanced Manufactured Melt Wires

Science Undergraduate Laboratory Internship (SULI) Program Report: Additive manufacturing (AM) based on direct-write technologies has emerged as the predominant method for the fabrication of passive sensors for the harsh operating environments seen in a nuclear reactor. Through the modification of previous methods, Idaho National Laboratory and Villanova University have improved the synthesis process for AM feedstock, which will allow for the improvement of advanced nuclear sensors and instrumentation. A major part of this work includes the synthesis process of relevant AM compatible feedstock to support the development, fabrication, and testing of AM sensors for peak temperature detection. For this report, bismuth, bismuth/platinum, tin, tin/silver, tin/zinc, indium, and indium/silver bi-metallic nanoparticles were synthesized using the polyol method, which will enhance temperature sensitivity and allow for miniaturization. To characterize the synthesized nanoparticles, we used x-ray fluorescence to evaluate the elemental composition of the nanoparticles and differential scanning calorimetry and thermogravimetric analysis to determine the melting point and mass loss of the samples. Results show that bi-metallic nanoparticles are a viable option for the fabrication of high-resolution AM melt wires. The temperature sensitivity can be brought to within 5°C and melt wires can be fabricated that are in the micrometer scale. This will expand the range of irradiation experiments melt wires can be used for and the measured temperature will be significantly more accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗