Search NASA⌕ Search

Engineering topics

Gauthier, M.

Publications and source records attributed to Gauthier, M..

At least 37 records · Page 2

High resolution x-ray Thomson scattering measurements from cryogenic hydrogen jets using the linac coherent light source

We present the first spectrally resolved measurements of x-rays scattered from cryogenic hydrogen jets in the single photon counting limit. The 120 Hz capabilities of the LCLS, together with a novel hydrogen jet design [J. B. Kim et al., Rev. Sci. Instrum. (these proceedings)], allow for the ability to record a near background free spectrum. Such high-dynamic-range x-ray scattering measurements enable a platform to study ultra-fast, laser-driven, heating dynamics of hydrogen plasmas. This measurement has been achieved using two highly annealed pyrolytic graphite crystal spectrometers to spectrally resolve 5.5 keV x-rays elastically and inelastically scattered from cryogenic hydrogen and focused on Cornell-SLAC pixel array detectors [S. Herrmann et al., Nucl. Instrum. Methods Phys. Res., Sect. A 718, 550 (2013)].

43 PARTICLE ACCELERATORS↗

High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmon scattering probing of electronic states in diamond at extreme conditions

Here, we measured the collective plasmon scattering spectrum from diamond at pressures approaching 370 GPa. Samples are dynamically compressed employing counter-propagating laser beams where the compression states are determined by Bragg scattering. X-ray energy loss spectroscopy with 8 keV photons from the Linac Coherently Light Source (LCLS) is then applied to probe the electronic state. The x-rays excite a collective interband transition, leading to a clear plasmon signal whose dispersion matches density functional theory. The data reveal a pressure-dependent Penn gap and demonstrate a non-conducting warm dense matter state for conditions of planetary interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability

Radiochromic films (RCF) are commonly used in dosimetry for a wide range of radiation sources (electrons, protons, and photons) for medical, industrial, and scientific applications. They are multi-layered, which includes plastic substrate layers and sensitive layers that incorporate a radiation-sensitive dye. Quantitative dose can be retrieved by digitizing the film, provided that a prior calibration exists. Here, to calibrate the newly developed EBT3 and HDv2 RCFs from Gafchromic™, we used the Stanford Medical LINAC to deposit in the films various doses of 10 MeV photons, and by scanning the films using three independent EPSON Precision 2450 scanners, three independent EPSON V750 scanners, and two independent EPSON 11000XL scanners. The films were scanned in separate RGB channels, as well as in black and white, and film orientation was varied. We found that the green channel of the RGB scan and the grayscale channel are in fact quite consistent over the different models of the scanner, although this comes at the cost of a reduction in sensitivity (by a factor ∼2.5 compared to the red channel). To allow any user to extend the absolute calibration reported here to any other scanner, we furthermore provide a calibration curve of the EPSON 2450 scanner based on absolutely calibrated, commercially available, optical density filters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanosecond formation of diamond and lonsdaleite by shock compression of graphite

Here, the shock-induced transition from graphite to diamond has been of great scientific and technological interest since the discovery of microscopic diamonds in remnants of explosively driven graphite. Furthermore, shock synthesis of diamond and lonsdaleite, a speculative hexagonal carbon polymorph with unique hardness, is expected to happen during violent meteor impacts. Here, we show unprecedented in situ X-ray diffraction measurements of diamond formation on nanosecond timescales by shock compression of pyrolytic as well as polycrystalline graphite to pressures from 19 GPa up to 228 GPa. While we observe the transition to diamond starting at 50 GPa for both pyrolytic and polycrystalline graphite, we also record the direct formation of lonsdaleite above 170 GPa for pyrolytic samples only. Our experiment provides new insights into the processes of the shock-induced transition from graphite to diamond and uniquely resolves the dynamics that explain the main natural occurrence of the lonsdaleite crystal structure being close to meteor impact sites.

36 MATERIALS SCIENCE↗

Band gap opening in strongly compressed diamond observed by x-ray energy loss spectroscopy

The extraordinary mechanical and optical properties of diamond are the basis of numerous technical applications and make diamond anvil cells a premier device to explore the high-pressure behavior of materials. However, at applied pressures above a few hundred GPa, optical probing through the anvils becomes difficult because of the pressure-induced changes of the transmission and the excitation of a strong optical emission. Such features have been interpreted as the onset of a closure of the optical gap in diamond, and can significantly impair spectroscopy of the material inside the cell. In contrast, a comparable widening has been predicted for purely hydrostatic compressions, forming a basis for the presumed pressure stiffening of diamond and resilience to the eventual phase change to BC8. We here present the first experimental evidence of this effect at geo-planetary pressures, exceeding the highest ever reported hydrostatic compression of diamond by more than 200 GPa and any other measurement of the band gap by more than 350 GPa. We here apply laser driven-ablation to create a dynamic, high pressure state in a thin, synthetic diamond foil together with frequency-resolved x-ray scattering as a probe. The frequency shift of the inelastically scattered x-rays encodes the optical properties and, thus, the behavior of the band gap in the sample. Using the ultra-bright x-ray beam from the Linac Coherent Light Source (LCLS), we observe an increasing direct band gap in diamond up to a pressure of 370 GPa. This finding points to the enormous strains in the anvils and the impurities in natural Type Ia diamonds as the source of the observed closure of the optical window. Our results demonstrate that diamond remains an insulating solid to pressures approaching its limit strength.

36 MATERIALS SCIENCE↗

Exploring Mbar shock conditions and isochorically heated aluminum at the MEC end station of the LCLS

Recent experiments performed at the Matter in Extreme Conditions end station (MEC) of the Linac Coherent Light Source (LCLS) have demonstrated the first spectrally resolved measurements of plasmons from isochorically heated aluminum. The experiments have been performed using a seeded 8-keV x-ray laser beam as a pump and probe to both volumetrically heat and scatter x-rays from aluminum. Collective x-ray Thomson scattering spectra show a well-resolved plasmon feature that is down-shifted in energy by 19 eV. In addition, Mbar shock pressures from laser-compressed aluminum foils using Velocity Interferometer System for Any Reflector (VISAR) have been measured. The combination of experiments fully demonstrates the possibility to perform warm dense matter studies at the LCLS with unprecedented accuracy and precision.

INST, MATSCI, PHYS, XFEL↗

Monochromatic short pulse laser produced ion beam using a compact passive magnetic device

High-intensity laser accelerated protons and ions are emerging sources with complementary characteristics to those of conventional sources, namely high charge, high current, and short bunch duration, and therefore can be useful for dedicated applications. However, these beams exhibit a broadband energy spectrum when, for some experiments, monoenergetic beams are required. We present here an adaptation of conventional chicane devices in a compact form (10 cm × 20 cm) which enables selection of a specific energy interval from the broadband spectrum. This is achieved by employing magnetic fields to bend the trajectory of the laser produced proton beam through two slits in order to select the minimum and maximum beam energy. The device enables a production of a high current, short duration source with a reproducible output spectrum from short pulse laser produced charged particle beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of longitudinal proton acceleration in exploded targets irradiated by intense short-pulse laser

It was recently shown that a promising way to accelerate protons in the forward direction to high energies is to use under-dense or near-critical density targets instead of solids. Simulations have revealed that the acceleration process depends on the density gradients of the plasma target. Indeed, under certain conditions, the most energetic protons are predicted to be accelerated by a collisionless shock mechanism that significantly increases their energy. We report here the results of a recent experiment dedicated to the study of longitudinal ion acceleration in partially exploded foils using a high intensity (∼5 × 10{sup 18} W/cm{sup 2}) picosecond laser pulse. We show that protons accelerated using targets having moderate front and rear plasma gradients (up to ∼8 μm gradient length) exhibit similar maximum proton energy and number compared to proton beams that are produced, in similar laser conditions, from solid targets, in the well-known target normal sheath acceleration regime. Particle-In-Cell simulations, performed in the same conditions as the experiment and consistent with the measurements, allow laying a path for further improvement of this acceleration scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of turbulence structures above a forest canopy using a wavelet transform

The wavelet transform is used to identify scales of large coherent structures present in atmospheric turbulence above the subarctic forest at Schefferville. Individual coherent structures contributing to much of the exchange between the forest and the atmosphere are depicted in terms of both scale and location using contour diagrams of wavelet transform coefficients. Three typical case studies of turbulence and flux observations were selected to examine the physical characteristics of these flux-filled events and their evolution with distance away from the forest canopy. A wavelet transform spectral technique is applied to vertical velocity, temperature, and turbulent heat flux data observed over the sparse coniferous forest to extract the relative importance of each scale present in those data series. The scale of turbulence structures in relation with their characteristic spacing is discussed.

Turner, B. J.↗