Search NASA⌕ Search

Engineering topics

Gentle, Jake P.

Publications and source records attributed to Gentle, Jake P..

At least 37 records · Page 2

Distributed Wind Resilience Metrics for Electric Energy Delivery Systems: Comprehensive Literature Review

While most people have a general concept of what it means to be “resilient,” an examination of definitions from different sources reveals that there are key commonalities but key differences as well. The lack of a generally accepted definition and application of resilience extends to electric energy delivery systems. Without an accepted definition, it is difficult to implement programs or processes to improve resiliency. In this paper, existing work from industry, regulatory bodies, and national laboratories to define and apply resilience to electric energy delivery systems is studied to understand the key components to define resilience and better understand associated metrics. This understanding is then applied to distributed wind for a specific example of how resilience of a system is affected by the technologies and generation sources used to support it. A key finding is that there is no “one size fits all” process for resilience. Each system has a “distinctiveness” characteristic, which qualifies the possibility of differences in resilience due to different threats, geography, stakeholders, risk tolerance, and mitigations. The distinctiveness characteristic extends to distributed wind, where different configurations may lend the distributed wind to contribute to the resilience of systems in a variety of ways. The findings of this research demonstrate the need for a resilience framework that can be readily applied by stakeholders to improve resilience based on the specific system, threat, risk tolerance and stakeholders.

17 WIND ENERGY↗

Systematic Analyzer Of Numeric Data

This system is meant to take large amounts of digital, automatically gathered data, and then organize it into a form that shows data integrity and plot, graph.

Lehmer, Jacob P.↗

Using Computational Fluid Dynamics of Wind Simulations Coupled With Weather Data to Calculate Dynamic Line Ratings

Dynamic line rating is a technology that allows for the rating of electrical conductors to be calculated based on local weather conditions rather than using ”worst-case” assumptions of weather conditions. The static ratings are typically based on weather conditions that are conservative in nature, and thus dynamic line rating may provide room to increase the current capacity. The local weather conditions may estimate conditions more accurately near the transmission lines accounting for terrain such as nearby hills. One way to estimate the local weather conditions is through the use of computational fluid dynamics. The results of a wind field simulation can be coupled with sparsely located weather stations to provide an accurate assessment of the wind speeds along the path of the conductor. Here, the wind field simulations are calculated using a steady state Reynolds-averaged Navier-Stokes model. These results along with local solar radiance measurements can be used to provide estimates of the steady state ampacity with the standard IEEE equations. An advanced test case for this process involves performing these simulations in a complex terrain, Hells Canyon, the deepest river gorge in North America. The results show that by using weather-based sensors without considering localized wind conditions, the available ampacity may be over-predicted significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling computational fluid dynamics with the high resolution rapid refresh model for forecasting dynamic line ratings

This study looks at forecasted dynamic line ratings in southern Idaho by using data from the High Resolution Rapid Refresh (HRRR) model for forecasted weather conditions. The HRRR model can provide accurate 18- hour forecasts with a 15-minute temporal resolution. Typical static ratings used for over head transmission lines use overly conservative assumptions for local weather conditions, such as using the maximum solar irradiance or temperature measured during the summer combined with low wind speed for an entire season. The HRRR forecast model used here has a high spatial resolution to provide local forecast conditions along the entire length of a transmission line. The area that is of interest in this study is in southern Idaho spanning a total of 15,000 square kilometers. The forecasted weather data is coupled with a computational fluid dynamics model of the wind in the region to improve the resolution to an even finer scale for resolving local convective cooling rates on each individual transmission line midpoint span. This high fidelity approach can be used to find the minimum ampacity limit across all given midpoints of a transmission line to determine the absolute minimum to be used for the line rating. The ability to increase the line rating above the conservative static approach with the forecasted weather data provides a large potential to alleviate congestion and provide data for the utility market transactions. Furthermore, this study shows that for the region of interest, using forecasted weather data coupled with CFD modeling will calculate DLR ampacity rating above static about 90% of the time, with only a small relative error in the forecasted ampacity over time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improvement of Transmission Line Ampacity Utilization by Weather-Based Dynamic Line Rating

Most of the existing overhead transmission lines (TLs) are assigned a static rating by considering the conservative environmental conditions (e.g., high ambient temperature and low wind speed). Such a conservative approach often results in underutilization of line ampacity because the worst conditions prevail only for a short period of time during the year. Dynamic line rating (DLR) utilizes local meteorological conditions and grid loadings to adaptively compute additional line ampacity headroom that may be available due to favorable local environmental conditions. This paper details Idaho National Laboratory-developed weather-based DLR, which utilizes a state-of-the-art general line ampacity state solver for real-time computation of thermal ratings of TLs. Performance of the proposed DLR solution is demonstrated in existing TL segments at AltaLink, Canada, and the potential benefits of the proposed DLR for enhanced transmission ampacity utilization are quantified. Moreover, we investigated a hypothetical case for emulating the impact of an additional wind plant near the test grid. Furthermore, the results for the given system and data configurations demonstrated that real-time ratings were above the seasonal static ratings for at least 76.6% of the time, with a mean increase of 22% over the static rating, thereby demonstrating huge potential for improvement on ampacity utilization.

17 WIND ENERGY↗

Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

17 WIND ENERGY↗

Using Dynamic Line Rating to Enhance Flexibility of Wind-involved Hybrid Energy System

By providing real-time overhead line ampacity, Dynamic Line Rating (DLR) is a potential technique to solve the transmission congestion issues that are threatening NPPs, especially when a nuclear plant is coupled with wind turbine generators. First, DLR can utilize the concurrent cooling effect and dynamic monitors on transmission lines to increase the line carry capacity and reduce congestion. Second, more frequent interactions between transmission lines and operators can increase the flexibility and create a more dynamic and responsive hybrid system. In general, DLR can increase the flexibility and optimize the efficiency of a hybrid system utilizing wind energy. DLR helps meet continuously fluctuating electricity demands with real-time observation of transmission lines for more accurate estimation of line carry capacity. For the fuel energy, DLR can contribute greatly in saving fuels and reducing carbon emission by providing timely information for adjusting generation levels. For HES's including NPPs, transmission congestion could be more serious and needs attention. Therefore, by providing additional transmission capacity, DLR can contribute to alleviate the congestion and congestion pricing impact that is threatening the current NPPs and prevent potential congestion that may constrain the operation of future hybrid system involved with a nuclear plant. However, either a fuel plant or nuclear plant is better coupled with a wind turbine to take advantage of the concurrent cooling effect and dynamic monitoring. The research team at Idaho National Laboratory, currently focused on the benefit of DLR technology to assist wind generation, is now exploring the feasibility of implementing the same technology into such HES and NPP. Future work will focus on the analysis of technique feasibility, challenges and benefit-cost analysis of integrating DLR into HES. Detailed studies are anticipated to evaluate the benefits of DLR on HES and NPP with transmission constraints. This paper explores a potential utilization of DLR in hybrid energy systems, especially those involving traditional fossil fuels or nuclear power coupled with wind energy. The goal is to increase the efficiency and flexibility of these types of hybrid systems in order to provide more secure, reliable and low-carbon energy.

17 WIND ENERGY↗

Optimum aggregation of geographically distributed flexible resources in strategic smart-grid/microgrid locations

This paper determines optimum aggregation areas for a given distribution network considering spatial distribution of loads and costs of aggregation. An elitist genetic algorithm combined with a hierarchical clustering and a Thevenin network reduction is implemented to compute strategic locations and aggregate demand within each area. The aggregation reduces large distribution networks having thousands of nodes to an equivalent network with few aggregated loads, thereby significantly reducing the computational burden. Furthermore, it not only helps distribution system operators in making faster operational decisions by understanding during which time of the day will be in need of flexibility, from which specific area, and in which amount, but also enables the flexibilities stemming from small distributed resources to be traded in various power/energy markets. A combination of central and local aggregation scheme where a central aggregator enables market participation, while local aggregators materialize the accepted bids, is implemented to realize this concept. The effectiveness of the proposed method is evaluated by comparing network performances with and without aggregation. Finally, for a given network configuration, steady-state performance of aggregated network is significantly accurate (≈ ±1.5% error) compared to very high errors associated with forecast of individual consumer demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatchable Renewable Energy Model for Microgrid Power System

Over the years, many research projects have been performed and focused on finding out the effective ways to balance the power demands and supply on the utility grid. The causes of the imbalance could be the increasing demands from the end users, the loss of power generation (generators down), faults on the transmission lines, power tripped due to overload, and weather conditions, etc. An efficient Load Frequency Control (LFC) can assure the desired electricity quality provided to the residential, commercial and industrial end users. A simulation model is built in this project to investigate the contribution of the modeling of dispatchable energy such as solar energy, wind power, hydro power and energy storage to the balance of the microgrid power system. An analysis of simplified feedback control system with proportional, integral, and derivative (PID) controller was performed. The purpose of this research is to investigate a simulation model that achieves certain degree of the resilient control for the microgrid.

14 SOLAR ENERGY↗

Development of The PaR Tool: Modernization of the Planning and Routing Scripts

The placement of an efficient route for power lines is a poorly understood. Owners of the land are often divided about whether to allow their land to have a pole placed. A planning and routing toolkit allows for the people to allow and deny access to land then instantly see the route recalculate. The original planning and routing scripts were the original proof of concept, there was a series of problems that greatly hindered the functionality of the system. The PaR Tool a fully featured application replaced the proof of concept scripts and the speed of the system was increased by 254%. It is readily extensible and far easier to use.

17 WIND ENERGY↗

A Comparison of Real-Time Thermal Rating Systems in the U.S. and the U.K.

Real-time thermal rating is a smart-grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative, constant seasonal rating based on seasonal and regional worst case scenarios rather than actual, say, local hourly weather predictions. This paper provides a report of two pioneering schemes-one in the U.S. and one in the U.K.-where real-time thermal ratings have been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Second, we critically compare both approaches and discuss their limitations. In doing so, we arrive at novel insights which will inform and improve future real-time thermal rating projects.

17 WIND ENERGY↗

INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

13 HYDRO ENERGY↗

Dynamic Line Rating: Research and Policy Evaluation

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative rating based on worst case scenarios. We demonstrate that observing the conditions in real time leads to additional capacity and safer operation. This paper provides a report of a pioneering scheme in the United States of America in which DLR has been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Secondly, we discuss limitations involved. In doing so, we arrive at novel insights which will inform and improve future DLR projects. Third, we provide a policy background and discussion to clarify the technology’s potential and identifies barriers to the imminent adoption of dynamic line rating systems. We provide suggestions for regulatory bodies about possible improvements in policy to encourage adoption of this beneficial technology.

17 WIND ENERGY↗

Malmstrom Air Force Base Wind Farm Economic Analysis

The Air Force’s Civil Engineer Support Agency and Global Strike Command (AFCESA and AFGSC) retained Idaho National Laboratory (INL) to perform an Economic Feasibility Study for a potential Malmstrom Air Force Base (MAFB) third party developed wind energy project in Great Falls, MT.

17 WIND ENERGY↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Government Renewable Energy Projects

The US Army Corps of Engineers has retained Idaho National Laboratory (INL) to conduct a study of past INL experiences and complete a report that identifies the processes that are needed for the development of renewable energy projects on government properties. The INL has always maintained expertise in power systems and applied engineering and INL’s renewable energy experiences date back to the 1980’s when our engineers began performing US Air Force wind energy feasibility studies and development projects. Over the last 20+ years of working with Department of Defense and other government agencies to study, design, and build government renewable projects, INL has experienced the do’s and don’ts for being successful with a project. These compiled guidelines for government renewable energy projects could include wind, hydro, geothermal, solar, biomass, or a variety of hybrid systems; however, for the purpose of narrowing the focus of this report, wind projects are the main topic discussed throughout this report. It is our thought that a lot of what is discussed could be applied, possibly with some modifications, to other areas of renewable energy. It is also important to note that individual projects (regardless the type) vary to some degree depending on location, size, and need but in general these concepts and directions can be carried over to the majority of government renewable energy projects. This report focuses on the initial development that needs to occur for any project to be a successful government renewable energy project.

17 WIND ENERGY↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗