Search NASA⌕ Search

Engineering topics

Gibner, P. S.

Publications and source records attributed to Gibner, P. S..

The isotopic composition of cosmic-ray B, C, N, and O - Evidence for an overabundance of O-18

New observations of galactic cosmic rays at higher energies (about 400-780 MeV/nucleon) than obtained in previous direct mass measurements have resulted in determinations of the isotopic composition of B, C, N, and O. The derived cosmic-ray source abundances provide evidence for an enhancement of O-18/O-16 by a factor of 5.6 +/- 1.9 over the solar system value and give a C-13/C-12 ratio consistent with the solar system abundance ratio, but lower than some recent measurements of the local interstellar medium.

Gibner, P. S.↗

Abundances of ultraheavy elements in the cosmic radiation - Results from HEAO 3

An analysis is presented that, for the first time, systematically normalizes the data from the HEAO 3 heavy nuclei experiment on the cosmic-ray abundances of all the elements heavier than germanium to that of iron. In the range of atomic number Z from 33 to 60, the analysis yields abundances of odd-even element pairs. The abundances are consistent with a cosmic-ray source having a composition similar to that of the solar system, but subject to source fractionation correlated with the first ionization potential (FIP) of each element. For Z greater than 60, the analysis yields abundances of element groups. For these heaviest nuclei, we find an enhancement of the abundance of the platinum group, elements with Z of 74-80, relative to that in propagated solar system source, and a corresponding increase in the abundance of the largely secondary elements in the 62-73 range. These abundances suggest that there is an enhancement of the r-process contribution to the source nuclei in the Z greater than 60 charge region. Over the entire region of charge, standard leaky box models of propagation satisfactorily model secondary production.

Binns, W. R.↗

Absolute and angular efficiencies of a microchannel-plate position-sensitive detector

This paper presents a characterization of a commercially available position-sensitive detector of energetic ions and neutrals. The detector consists of two microchannel plates followed by a resistive position-encoding anode. The work includes measurement of absolute efficiencies of H(+), He(+), and O(+) ions in the energy range between 250 and 5000 eV, measurement of relative detection efficiencies as a function of particle impact angle, and a simple method for accurate measurement of the time at which a particle strikes the detector.

Gao, R. S.↗