Search NASA⌕ Search

Engineering topics

Glagolev, V.

Publications and source records attributed to Glagolev, V..

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

The Mu2e Digitizer ReAdout Controller (DiRAC): characterization and radiation hardness

The Mu2e experiment at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photo-multipliers and fast front-end, and digitization electronics. The digitization board is named DiRAC (Digitizer ReAdout Controller) and 140 cards are needed for the readout of the full calorimeter. The DiRACs are hosted in crates located on the external surface of calorimeter disks, inside the detector solenoid cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. Several version of prototypes were validated for operation in a high-vacuum (10−4 Torr) and under a 1T magnetic field. An extensive radiation hardness qualification campaign, carried out with photons, 14 MeV neutron beams, and 200 MeV protons, certified the DiRAC design to sustain doses up to 12 Krad, neutron fluences up to ∼ 1011 1 MeV neq/cm2, and very low occurrences of single-event effects. The qualification campaigns and quality assurance procedures will be reviewed.

43 PARTICLE ACCELERATORS↗

Measurements of neutrino oscillation parameters from the T2K experiment using $$3.6\times 10^{21}$$ protons on target

Abstract The T2K experiment presents new measurements of neutrino oscillation parameters using $$19.7(16.3)\times 10^{20}$$ 19.7 ( 16.3 ) × 10 20 protons on target (POT) in (anti-)neutrino mode at the far detector (FD). Compared to the previous analysis, an additional $$4.7\times 10^{20}$$ 4.7 × 10 20 POT neutrino data was collected at the FD. Significant improvements were made to the analysis methodology, with the near-detector analysis introducing new selections and using more than double the data. Additionally, this is the first T2K oscillation analysis to use NA61/SHINE data on a replica of the T2K target to tune the neutrino flux model, and the neutrino interaction model was improved to include new nuclear effects and calculations. Frequentist and Bayesian analyses are presented, including results on $$\sin ^2\theta _{13}$$ sin 2 θ 13 and the impact of priors on the $$\delta _{\textrm{CP}}$$ δ CP measurement. Both analyses prefer the normal mass ordering and upper octant of $$\sin ^2\theta _{23}$$ sin 2 θ 23 with a nearly maximally CP-violating phase. Assuming the normal ordering and using the constraint on $$\sin ^2\theta _{13}$$ sin 2 θ 13 from reactors, $$\sin ^2\theta _{23}=0.561^{+0.021}_{-0.032}$$ sin 2 θ 23 = 0 . 561 - 0.032 + 0.021 using Feldman–Cousins corrected intervals, and $$\varDelta {}m^2_{32}=2.494_{-0.058}^{+0.041}\times 10^{-3}~\text {eV}^2$$ Δ m 32 2 = 2 . 494 - 0.058 + 0.041 × 10 - 3 eV 2 using constant $$\varDelta \chi ^{2}$$ Δ χ 2 intervals. The CP-violating phase is constrained to $$\delta _{\textrm{CP}}=-1.97_{-0.70}^{+0.97}$$ δ CP = - 1 . 97 - 0.70 + 0.97 using Feldman–Cousins corrected intervals, and $$\delta _{\textrm{CP}}=0,\pi $$ δ CP = 0 , π is excluded at more than 90% confidence level. A Jarlskog invariant of zero is excluded at more than $$2\sigma $$ 2 σ credible level using a flat prior in $$\delta _{\textrm{CP}},$$ δ CP , and just below $$2\sigma $$ 2 σ using a flat prior in $$\sin \delta _{\textrm{CP}}.$$ sin δ CP . When the external constraint on $$\sin ^2\theta _{13}$$ sin 2 θ 13 is removed, $$\sin ^2\theta _{13}=28.0^{+2.8}_{-6.5}\times 10^{-3},$$ sin 2 θ 13 = 28 . 0 - 6.5 + 2.8 × 10 - 3 , in agreement with measurements from reactor experiments. These results are consistent with previous T2K analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation.

47 OTHER INSTRUMENTATION↗