Godfrey, Devon J

Publications and source records attributed to Godfrey, Devon J.

Comparing Digital Tomosynthesis to Cone-Beam CT for Position Verification in Patients Undergoing Partial Breast Irradiation

Purpose: To evaluate digital tomosynthesis (DTS) technology for daily positioning of patients receiving accelerated partial breast irradiation (APBI) and to compare the positioning accuracy of DTS to three-dimensional cone-beam computed tomography (CBCT). Methods and Materials: Ten patients who underwent APBI were scanned daily with on-board CBCT. A subset of the CBCT projections was used to reconstruct a stack of DTS image slices. To optimize soft-tissue visibility, the DTS images were reconstructed in oblique directions so that the tumor bed, breast tissue, ribs, and lungs were well separated. Coronal and sagittal DTS images were also reconstructed. Translational shifts of DTS images were obtained on different days from the same patients and were compared with the translational shifts of corresponding CBCT images. Seventy-seven CBCT scans and 291 DTS scans were obtained from nine evaluable patients. Results: Tumor beds were best visible in the oblique DTS scans. One-dimensional positioning differences between DTS and CBCT images were 0.8-1.7 mm for the six patients with clips present and 1.2-2.0 mm for the three patients without clips. Because of the limited DTS scan angle, the DTS registration accuracy along the off-plane direction is lower than the accuracy along the in-plane directions. Conclusions: For patients receiving APBI, DTS localization offers comparable accuracy to CBCT localization for daily patient positioning while reducing mechanical constraints and imaging dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map

We developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume. The deformation field is solved by minimizing bending energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. The new patient DTS volume is then obtained by deforming the prior patient CBCT or CT volume according to the solution to the deformation field. This method is novel because it is the first method to combine deformable registration with limited angle image reconstruction. The method was tested in 2D cases using simulated projections of a Shepp-Logan phantom, liver, and head-and-neck patient data. The accuracy of the reconstruction was evaluated by comparing both organ volume and pixel value differences between DTS and CBCT images. In the Shepp-Logan phantom study, the reconstructed pixel signal-to-noise ratio (PSNR) for the 60 deg. DTS image reached 34.3 dB. In the liver patient study, the relative error of the liver volume reconstructed using 60 deg. projections was 3.4%. The reconstructed PSNR for the 60 deg. DTS image reached 23.5 dB. In the head-and-neck patient study, the new method using 60 deg. projections was able to reconstruct the 8.1 deg. rotation of the bony structure with 0.0 deg. error. The reconstructed PSNR for the 60 deg. DTS image reached 24.2 dB. In summary, the new reconstruction method can optimally estimate the volumetric information in DTS images using 60 deg. projections. Preliminary validation of the algorithm showed that it is both technically and clinically feasible for image guidance in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast reconstruction of digital tomosynthesis using on-board images

Digital tomosynthesis (DTS) is a method to reconstruct pseudo three-dimensional (3D) volume images from two-dimensional x-ray projections acquired over limited scan angles. Compared with cone-beam computed tomography, which is frequently used for 3D image guided radiation therapy, DTS requires less imaging time and dose. Successful implementation of DTS for fast target localization requires the reconstruction process to be accomplished within tight clinical time constraints (usually within 2 min). To achieve this goal, substantial improvement of reconstruction efficiency is necessary. In this study, a reconstruction process based upon the algorithm proposed by Feldkamp, Davis, and Kress was implemented on graphics hardware for the purpose of acceleration. The performance of the novel reconstruction implementation was tested for phantom and real patient cases. The efficiency of DTS reconstruction was improved by a factor of 13 on average, without compromising image quality. With acceleration of the reconstruction algorithm, the whole DTS generation process including data preprocessing, reconstruction, and DICOM conversion is accomplished within 1.5 min, which ultimately meets clinical requirement for on-line target localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic registration between reference and on-board digital tomosynthesis images for positioning verification

The authors developed a hybrid multiresolution rigid-body registration technique to automatically register reference digital tomosynthesis (DTS) images with on-board DTS images to guide patient positioning in radiation therapy. This hybrid registration technique uses a faster but less accurate static method to achieve an initial registration, followed by a slower but more accurate adaptive method to fine tune the registration. A multiresolution scheme is employed in the registration to further improve the registration accuracy, robustness, and efficiency. Normalized mutual information is selected as the criterion for the similarity measure and the downhill simplex method is used as the search engine. This technique was tested using image data both from an anthropomorphic chest phantom and from eight head-and-neck cancer patients. The effects of the scan angle and the region-of-interest (ROI) size on the registration accuracy and robustness were investigated. The necessity of using the adaptive registration method in the hybrid technique was validated by comparing the results of the static method and the hybrid method. With a 44 deg. scan angle and a large ROI covering the entire DTS volume, the average of the registration capture ranges in single-axis simulations was between -31 and +34 deg. for rotations and between -89 and +78 mm for translations in the phantom study, and between -38 and +38 deg. for rotations and between -58 and +65 mm for translations in the patient study. Decreasing the DTS scan angle from 44 deg. to 22 deg. mainly degraded the registration accuracy and robustness for the out-of-plane rotations. Decreasing the ROI size from the entire DTS volume to the volume surrounding the spinal cord reduced the capture ranges to between -23 and +18 deg. for rotations and between -33 and +43 mm for translations in the phantom study, and between -18 and +25 deg. for rotations and between -35 and +39 mm for translations in the patient study. Results also showed that the hybrid registration technique had much larger capture ranges than the static method alone in registering the out-of-plane rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating reconstruction of reference digital tomosynthesis using graphics hardware

The successful implementation of digital tomosynthesis (DTS) for on-board image guided radiation therapy (IGRT) requires fast DTS image reconstruction. Both target and reference DTS image sets are required to support an image registration application for IGRT. Target images are usually DTS image sets reconstructed from on-board projections, which can be accomplished quickly using the conventional filtered backprojection algorithm. Reference images are DTS image sets reconstructed from digitally reconstructed radiographs (DRRs) previously generated from conventional planning CT data. Generating a set of DRRs from planning CT is relatively slow using the conventional ray-casting algorithm. In order to facilitate DTS reconstruction within a clinically acceptable period of time, we implemented a high performance DRR reconstruction algorithm on a graphics processing unit of commercial PC graphics hardware. The performance of this new algorithm was evaluated and compared with that which is achieved using the conventional software-based ray-casting algorithm. DTS images were reconstructed from DRRs previously generated by both hardware and software algorithms. On average, the DRR reconstruction efficiency using the hardware method is improved by a factor of 67 over the software method. The image quality of the DRRs was comparable to those generated using the software-based ray-casting algorithm. Accelerated DRR reconstruction significantly reduces the overall time required to produce a set of reference DTS images from planning CT and makes this technique clinically practical for target localization for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗